Summary of Contents for Highgrove SE

Page 1: ...Knightsbridge SE Highgrove SE Multi fuel burning stoves with optional wood burning stoveasy grate Installation user instructions To be left with customer Reference NS5 6 Issue 1 Date 8th January 2014 ...

Page 2: ...2 4 The chimney 2 5 Pipe connections 2 6 Connecting to a masonry chimney 2 7 Connecting to a steel chimney 2 8 Ventilation Fresh air supply 2 9 Draft conditions 2 9 1 Assembling the handle 2 9 2 Commissioning and handover 3 0 User Manual 3 1 Choice of fuel 3 2 Use 3 2 1 Use with wood 3 2 2 Use with solid fuel 3 3 Ash Removal 3 3 1 Maintenance 3 3 2 Cleaning glass 3 3 3 External surface cleaning 3 ...

Page 3: ...Always ensure that there is an adequate air supply into the room containing the stove It is very important that flue ways are regularly swept checked by an approved person It is recommended that sweeping and checking should be done at least twice each year The installer must ensure that the chimney is examined for soundness and suitability before the appliance is installed Remedial action should b...

Page 4: ...hose countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorized fuels have been exempted by an Order made and signed by the Secretary of State or Minis...

Page 5: ...ghtsbridge SE and Highgrove SE appliances have been approved by HETAS Ltd as intermittent operating appliances for burning wood logs and approved smokeless fuels Installation introduction with technical data 1 0 Technical data Knightsbridge SE Highgrove SE Material Cast iron Finish High temp resistant paint Fuel Wood Approved wood logs Approved smokeless fuels Log length 30cm maximum Stove outlet ...

Page 6: ...0 C Ancit Operational mode Intermittent Technical data with optional Stoveasy grate Material Cast iron Finish High temp resistant paint Fuel Wood Approved wood logs Log length 30cm maximum Stove outlet collar positions Top and rear Stove collar dimension Internal diameter 125mm 113cm2 cross section Approx weight 106kgs Dimensions distances etc Figure 2 Technical data according to EN 13240 A2 2004 ...

Page 7: ...ocedure 2 2 Installing this stove The stove and chimney installations MUST comply with all current National and Local Building Regulations and any rules in force including current issues of British Standard BS 8303 code of practice for installation of domestic heating and cooking appliances burning solid mineral fuel and British Standards BS EN 15287 1 2007 design installation and commissioning of...

Page 8: ... the baffle is in correct position See figure 1 1 This shows how to locate the baffle Before lighting the stove for the first time confirm the baffle is in correct location Position grate banking bar correctly See figures 1 1 and 1 2 If the stove is to be used for wood the tertiary air control must be set to the fully open position therfore leaving the tertiary air intake fully open and unrestrict...

Page 9: ......

Page 10: ...an be placed directly onto a wooden floor providing that it is covered by a metal plate or other suitable non inflammable material The minimum thickness is 12mm Any flooring made of combustible material such as linoleum carpets etc must be removed from under the floor plate Requirements for protecting combustible flooring in front rear sides of the stove must be in accordance with national laws an...

Page 11: ......

Page 12: ...es of stove can be reduced to 50mm refer to building regulations any rules in force However it is recommended that the measurement between the sides rear of stove to be as large as possible above this dimension as the efficiency of this stove is dependent on the clearances as shown in figure 2 Ceiling protection Refer to building regulations any other rules in force including BS 8303 and BS EN 152...

Page 13: ...chimney is generally hard to keep warm and results in poor draft In cases where there is an oversized masonry chimney it is recommended that the chimney be lined using an appropriate chimney lining system with the correct internal diameter With respect to the chimney termination all chimneys should terminate in accordance with national and Local Building Regulations Note that National and Local Re...

Page 14: ...on of 100m for straight flues or 125mm for flues with bends or offsets Refer to current Building regulations any rules in force including BS 8303 and BS EN 15287 1 2007 2 7 Connecting to a steel chimney Refer to building regulations any other rules in force including BS 8303 and BS EN 15287 1 2007 If your installation involves taking the chimney straight up and through the ceiling you must comply ...

Page 15: ...the flue system and limit the length of the offset between bends Refer to building regulations and any other rules in force 2 8 Ventilation Fresh air supply Refer to building regulations any other rules in force including BS 8303 and BS EN 15287 1 2007 Knightsbridge SE Highgrove SE nominal heat output 4 9 5 0 kw Knightsbridge SE Highgrove SE with optional Stoveasy grate nominal heat output 4 8 kw ...

Page 16: ...up sheet of newspaper in the flue way of the stove and ignite The outside temperature is too high e g during the summer months There is no air movement wind outside The chimney is not tall enough with the result that the terminal sits in the lee of the roof surface or in the vicinity of tall trees or neighboring buildings These conditions are also associated with downdraft where the flue gases are...

Page 17: ... is used to operate this stove Bakelite Handle Step 1 Position Bakelite handle screw and washer fixings into correct position with steel elbow Tighten screw securely Stainless Steel Handle The optional stainless steel handle is designed to be of plug in and plug out type this will enable the handle to be removed when not operating the door to avoid excessive heat transfer into the handle when the ...

Page 18: ...and such persons must be supervised at all times It is also recommended that all other people should use a fireguard in accordance with BS 8423 2002 at all times when the stove is alight or hot Use the long key provided for operating and adjusting all air controls including the riddling control removal replacement of ash pan when necessary It is recommended that when operating this stove an approv...

Page 19: ...inguisher to contend with small fires resulting from burning embers A practical evacuation plan A plan to deal with a chimney fire as follows a Notify the fire department b Prepare all occupants for immediate evacuation c If safely possible close all air openings into the stove 3 1 Choice of fuel Recommended fuel Wood Use hard wood logs Although you can fire this product with almost all kinds of w...

Page 20: ...gs and any form of bituminous coal or petroleum based coke Do not use the appliance as an incinerator or use any liquid fuels This is very dangerous may damage the product and pollute the atmosphere 3 2 Use Odours when using the stove for the first time Painted products The stove may emit an irritating gas when used for the first time and it may smell a little The gas is not toxic but the room sho...

Page 21: ...that should be used 3 2 1 Use with wood See figure 4 Important The Tertiary air control must be set to the fully open position therfore leaving the tertiary air intake fully open and unrestricted when burning wood Lighting re fuelling Very Important 1 To achieve clean burning and maximize the performance and efficiency of the appliance it is important to raise the temperature of the stove and chim...

Page 22: ... fuel etc This means that it may take some time before you get to know the correct functioning of the stove under any given circumstances Note To load fuel the door should be opened slowly avoiding a sudden rush of intake air so that smoke does not escape into the room Operation with door left open Operation with the door open can cause excessive smoke The appliance must not be operated with the a...

Page 23: ...llow the initial volatiles in the fuel to burn Adjust the primary air control to the desired position Fuel overloading Never overload the firebox The maximum amount of fuel specified in this manual should not be exceeded overloading can cause damage and smoke ...

Page 24: ......

Page 25: ......

Page 26: ...is not alight and cool open both the glass and lower ash pan doors remove air funnel and sweep ashes into the ash pan with a suitable brush or alternatively use a specialist ash vacuum for this task Always empty the ash pan at least once a day or whenever it is full of ashes Use the key provided to remove and replace ash pan into position Never allow the ash pan to overfill allowing ash to be in c...

Page 27: ...lly be burned off when the air wash vent is opened all the way and a fire is burning briskly in the stove Good advice For normal cleaning when the stove is extinguished and cold moisten a paper towel with warm water and add some cooled ash from the burn chamber Rub it over the glass and then clean the glass with clean water then dry If it is necessary to clean the glass more thoroughly we recommen...

Page 28: ... advice from a qualified chimney stove specialist Problem Probable causes Action Fire difficult to start Fire goes out Wood green too damp or poor quality Logs are too big Air starvation Insufficient draught Use the recommended fuel To light the fire use small very dry twigs To maintain the fire use split logs Open lower spin wheel and top air control lever Check that the flue is not obstructed sw...

Page 29: ...t output Incorrect Fuels Use fuel Recommended 3 5 Replacement parts Only use replacement parts recommended by the manufacturer Modifications to this appliance must not be made 3 6 Parts list for Knightsbridge SE and Highgrove SE multi fuel Spare parts Casting iron parts Number Name Dimension Quantity Number Name Weight kg Quantity 17 Air Control Plate 352 21 4 1 5 Hob 11 69 1 19 Pull Rod Bracket 1...

Page 30: ... 18 Back Air Damper 0 26 1 48 Countersunk Inner Hexagon Bolts M6 8 11 36 Air Control 0 15 1 53 Countersunk Inner Hexagon Bolts M6 20 1 49 Grate 1 43 1 57 Spring Φ8 3 51 Banking Plate Locking Bar 0 2 1 58 Spring Gasket Φ6 2 52 Flue Cover Banking Plate 0 77 1 61 Hinge A 46 18 5 2 23 Legs 0 69 4 42 Handle Hook 1 50 Flue 1 1 1 62 Hinge B 46 17 2 46 Ash pan Lifter 0 36 1 63 Hinge Axle 5 50 2 89 Stainle...

Page 31: ...Details Knightsbridge SE Highgrove SE Multi fuel Dimension 585 398 606 Flue collar size Φ125mm Burning Chamber Dimension 450 241 188 GW 110 kg NW 106 5 kg Nominal Output Wood 4 9Kw Smokeless fuel 5Kw ...

Page 32: ...ad Bolts M6 10 4 11 Grate 5 42 1 31 Self locking Nut M8 2 12 Middle Baffle 3 87 1 32 Hexagon Head Bolts M6 30 2 43 Lower Baffle 2 87 1 35 stainless steel blanking knob Φ12 8 1 15 Top Baffle 30 5 1 37 Countersunk Inner Hexagon Bolts M4 12 1 16 Banking Bar 1 52 1 38 Primary Air Cover 220 33 54 4 1 10 Grate Frame 5 42 1 41 Primary Air Shutter 262 40 4 1 14 Air Wash Plate 0 55 1 44 Air Wash Pin M5 14 ...

Page 33: ...anner 4mm 1 56 Flat Gasket Φ6 22 3 54 Countersunk Inner Hexagon Bolts M6 30 3 Details KnightsbridgeSE Highgrove SE with optional Stoveasy grate Dimension 585 398 606 Flue collar size Φ125mm Burning Chamber Dimension 450 241 188 GW 110 kg NW 106 5 kg Nominal Output 4 8Kw ...