Instructions
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671.
The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty.
RPM 500
Wiring Diagram
PROBLEM
RESOLUTION
Lights will not
switch OFF
•
Check time settings (Black bar denotes position of dip switches).
•
Check Connections.
•
Occupancy Detector is too close to lights - Re-position away from lighting, forced air ventilation or heating sources. Ensure Occupancy Detector is not
looking directly at heat source or is in direct sunlight.
•
Occupancy Detector is re-triggered – Check area is left unoccupied for longer than time setting using an accurate time piece.
•
Capacitor must be fitted if switching low wattage loads, LEDs or fitted at coil if switching contactors.
Lights will not
switch ON
•
Check Terminal connections.
•
Lux set too low- Turn up lux level towards the plus and wait 30 seconds for sensor to adjust.
Light switches OFF
then immediately
comes back ON
•
Check terminal connections.
•
Occupancy Detector may be detecting normally find potential source that is triggering Occupancy Detector. Best method is to cover detector with thick
material to eliminate potential trigger source.
•
Occupancy Detector is seeing infra-red heat from lighting load.
•
Capacitor must be fitted if switching low wattage loads, LEDs or fitted at coil if switching contactors.
TROUBLESHOOTING
LIVE IN
LIVE OUT
NEUTRAL
SL L
SL L
N
LIVE IN
LIVE OUT
NEUTRAL
SL L
LIVE IN
LIVE OUT
NEUTRAL
SL L
N
N SL L
5 - 7m
4 - 6m
5 - 7m
3 - 4m
SL L
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
SL L
SL L
N
N
Single
switching
Multiple switching
Detection - 360˚
5-7m
3-4m
4-6m
Newlec Helpline: 0800 783 6909 Manufacturers Address: Newey & Eyre Eagle Court 2, Hatchford Way, Birmingham B26 3RZ