1. Prior to fitting ensure mains power is switched OFF and live in, switch live and neutral wires are identified. Also where applicable
remove metal back box lugs that are not being used.
2. For installation purposes, set the dip switches for test mode as shown in Timing Diagram and gently rotate the lux pot anti-
clockwise towards the plus (+).
3. Securely fit live in, live out and neutral into the terminals marked Lin, Lout & N.
4. Turn mains power ON.
5. To test the Occupancy Detector timer leave the area and the load will switch OFF in approximately 60 seconds as long as no
movement or external sources are detected.
6. To test the timer re-enter the area and the Occupancy Detector Timer will detect movement and trigger the load ON.
7. Select time delay required using Timing Diagram and the lux level pot to desired ambient light level required.
8. Ensure the timer is secured to the back box securely. Do not press the Occupancy Detector dome for any reason.
9. A capacitor will be required when switching low power or low energy lighting. For example: LED, 2-D fittings, energy saving lamps,
etc. One capacitor per circuit must be fitted at the light fitting. A Newlec NL5705A Capacitor will be required.
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671.
The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty.
Instructions
Newlec Helpline: 0800 783 6909
RPM 500
PRODUCT RANGE
OCCUPANCY DETECTOR -
WALL MOUNTED
PART NUMBER
NL5706A THREE WIRE
FEATURES
Time Delay 2min-1hr
Voltage 240Va.c. 50Hz
Test mode function added for your convenience.
Load Rating for all lighting loads that are LED, Compact
Fluorescent, Fluorescent, Incandescent and Resistive.
(This Occupancy Detector can be used with contactors provided
a capacitor is fitted across the coil).
FITTING AND OPERATION INSTRUCTIONS
Timing Diagram
Please note that the BLACK BAR denotes the position of the dip switch
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DI
P
ON DI
P
ON DI
P
ON DI
P
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DI
P
ON DI
P
ON DI
P
ON DI
P
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DI
P
ON DI
P
ON DI
P
ON DI
P
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DI
P
ON DI
P
ON DI
P
ON DI
P
30m
AREA OF HIGH
SENSITIVITY
AREA OF LOW
SENSITIVITY
6m
SL
LUX
SEN
L
N
L
N
SL
LUX
SEN
L
N
L
N
LIVE IN
NEUTRAL
LIVE IN
LIVE OUT
NEUTRAL
P
O
T
P
O
T
SL
LUX
SEN
L
N
L
N
LIVE IN
NEUTRAL
LIVE IN
LIVE OUT
NEUTRAL
N SL L
TOP
10-15 sec
Test mode
20mins
2 mins
25 mins
3 mins
30 mins
4 mins
35 mins
5 mins
40 mins
7 mins
45 mins
10 mins
50 mins
15 mins
60 mins