Newlec NL5706A Instructions Download Page 1

1.  Prior to fitting ensure mains power is switched OFF and live in, switch live and neutral wires are identified. Also where applicable  
  remove metal back box lugs that are not being used.
2.   For installation purposes, set the dip switches for test mode as shown in Timing Diagram and gently rotate the lux pot anti-   
  clockwise towards the plus (+).
3.   Securely fit live in, live out and neutral into the terminals marked Lin, Lout & N.  
4.   Turn mains power ON.
5.   To test the Occupancy Detector timer leave the area and the load will switch OFF in approximately 60 seconds as long as no   
  movement or external sources are detected.
6.   To test the timer re-enter the area and the Occupancy Detector Timer will detect movement and trigger the load ON.
7.   Select time delay required using Timing Diagram and the lux level pot to desired ambient light level required.
8.   Ensure the timer is secured to the back box securely. Do not press the Occupancy Detector dome for any reason.
9.   A capacitor will be required when switching low power or low  energy lighting. For example: LED, 2-D fittings, energy saving lamps,  
  etc. One capacitor per circuit must be fitted at the light fitting. A Newlec NL5705A Capacitor will be required.   

IMPORTANT NOTICE

All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671.  

The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty. 

Instructions

Newlec Helpline: 0800 783 6909

RPM 500

PRODUCT RANGE

OCCUPANCY DETECTOR -

WALL MOUNTED

PART NUMBER

NL5706A THREE WIRE

FEATURES

  Time Delay 2min-1hr 

  Voltage 240Va.c. 50Hz  
  Test mode function added for your convenience.

  Load Rating for all lighting loads that are LED, Compact 

Fluorescent,  Fluorescent, Incandescent and Resistive.  
(This Occupancy Detector can be used with contactors provided 
a capacitor is fitted across the coil). 

FITTING AND OPERATION INSTRUCTIONS

Timing Diagram

Please note that the BLACK BAR denotes the position of the dip switch

4.
3.
2.
1.

4.
3.
2.
1.

4.
3.
2.
1.

4.
3.
2.
1.

ON       DI

P

ON       DI

P

ON       DI

P

ON       DI

P

4.
3.
2.
1.

4.
3.
2.
1.

4.
3.
2.
1.

ON       DI

P

ON       DI

P

ON       DI

P

ON       DI

P

4.
3.
2.
1.

4.
3.
2.
1.

4.
3.
2.
1.

ON       DI

P

ON       DI

P

ON       DI

P

ON       DI

P

4.
3.
2.
1.

4.
3.
2.
1.

4.
3.
2.
1.

4.
3.
2.
1.

ON       DI

P

ON       DI

P

ON       DI

P

ON       DI

P

30m

AREA OF HIGH

SENSITIVITY

AREA OF LOW

SENSITIVITY

6m

SL

LUX

SEN

L

N

L

N

SL

LUX

SEN

L

N

L

N

LIVE IN

NEUTRAL

LIVE IN

LIVE OUT

NEUTRAL

P

O

T

P

O

T

SL

LUX

SEN

L

N

L

N

LIVE IN

NEUTRAL

LIVE IN

LIVE OUT

NEUTRAL

N SL L

TOP

10-15 sec

Test mode

20mins

2 mins

25 mins

3 mins

30 mins

4 mins

35 mins

5 mins

40 mins

7 mins

45 mins

10 mins

50 mins

15 mins

60 mins