background image

 

 

                                                                                                                                                                             

216

 

 

Rectangular Barcode 

Data Matrix has two formats: 

Square barcodes having the same amount of modules in length and width: 10*10, 12*12.... 144*144. 

Rectangular barcodes having different amounts of models in length and width: 6*16, 6*14...14*22. 

 

 

 

 

@DMCREC1

 

** Enable Rectangular Barcode

 

 

 

 

 

 

@DMCREC0

 

Disable Rectangular Barcode 

 

Data Matrix Inverse 

Regular barcode: Dark bars on a bright background. 

Inverse barcode: Bright bars on a dark background. 

 

 

 

 

@DMCINV0

 

Decode Regular Data Matrix Barcodes Only

 

 

 

 

 

 

@DMCINV1

 

Decode Inverse Data Matrix Barcodes Only 

Summary of Contents for NLS-NVH300 Series

Page 1: ...NLS NVH300 Industrial Handheld Barcode Scanner User Guide ...

Page 2: ...e changes to any software or hardware to improve reliability function or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted by Fujian Newland Auto ID Tech Co Ltd or third party The user corporation or individual shall not duplicate in whole or in part distribute modify de...

Page 3: ...Revision History Version Description Date V1 0 0 Initial release September 5th 2019 ...

Page 4: ...ront View 6 Top View 7 Data Port 8 Connecting the NVH300 to a Host 9 Using USB Cable 9 Using RS 232 Cable 10 Using PS 2 Cable 10 Connect the NVH300 DP Communication Data Cable 11 Remove theNVH300 DP Communication Data Cable 11 Removing the Cable of NVH300 HD 12 Power On Power Off Reboot 12 Maintenance 13 Scanning Instructions 13 Chapter 2 EasySetEX 15 Introduction 15 Main Features 15 Chapter 3 Sys...

Page 5: ...ep 26 Good Read Beep 26 Good Read Beep Duration 27 Good Read Beep Frequency 28 Number of Good Read Beeps 29 Good Read Beep Interval Time 30 Good Read Vibration 30 Good Read Vibration Duration 31 Scan Mode 31 Decode Session Timeout 34 Timeout between Decodes 34 Reread Timeout 35 Good Read Delay 36 Image Decoding Timeout 37 Scanning Preference 38 Read Barcode On Off 39 Transmit Not Good Read Message...

Page 6: ... 55 Introduction 55 USB HID Keyboard 56 USB Country Keyboard Types 57 Beep on Unknown Character 61 Emulate ALT Keypad 62 Code Page 63 Unicode Encoding 66 Function Key Mapping 67 ASCII Function Key Mapping Table 68 ASCII Function Key Mapping Table Continued 69 Inter Keystroke Delay 70 Caps Lock 70 Convert Case 71 Emulate Numeric Keypad 71 Polling Rate 74 USB CDC 76 USB HID POS 76 Introduction 76 Ac...

Page 7: ... On Code 87 5 Digit Add On Code 88 Add On Code Required 88 Add On Code Separator 89 Convert EAN 8 to EAN 13 89 EAN 13 91 Restore Factory Defaults 91 Enable Disable EAN 13 91 Transmit Check Character 92 2 Digit Add On Code 92 5 Digit Add On Code 94 Add On Code Required 94 Add On Code Separator 95 EAN 13 Beginning with 290 Add On Code Required 95 EAN 13 Beginning with 378 379 Add On Code Required 96...

Page 8: ...Add On Code Required 108 Add On Code Separator 109 Transmit Preamble Character 109 Interleaved 2 of 5 111 Restore Factory Defaults 111 Enable Disable Interleaved 2 of 5 111 Set Length Range for Interleaved 2 of 5 112 Check Character Verification 113 Febraban 114 Febraban Barcode Transmit Delay 114 ITF 14 118 Restore Factory Defaults 118 Enable Disable ITF 14 118 ITF 6 120 Restore Factory Defaults ...

Page 9: ...tart Stop Character 137 Code 93 139 Restore Factory Defaults 139 Enable Disable Code 93 139 Set Length Range for Code 93 140 Check Character Verification 141 China Post 25 143 Restore Factory Defaults 143 Enable Disable China Post 25 143 Set Length Range for China Post 25 144 Check Character Verification 145 GS1 128 UCC EAN 128 147 Restore Factory Defaults 147 Enable Disable GS1 128 147 Set Length...

Page 10: ...r Industrial 25 164 Check Character Verification 165 Standard 25 167 Restore Factory Defaults 167 Enable Disable Standard 25 167 Set Length Range for Standard 25 168 Check Character Verification 169 Plessey 175 Restore Factory Defaults 175 Enable Disable Plessey 175 Set Length Range for Plessey 176 Check Character Verification 177 MSI Plessey 179 Restore Factory Defaults 179 Enable Disable MSI Ple...

Page 11: ...gth Range for Micro PDF417 198 QR Code 199 Restore Factory Defaults 199 Enable Disable QR Code 199 Set Length Range for QR Code 200 QR Twin Code 201 QR Inverse 202 Character Encoding 202 QR ECI Output 204 Micro QR Code 205 Restore Factory Defaults 205 Enable Disable Micro QR 205 Set Length Range for Micro QR 206 Aztec 207 Restore Factory Defaults 207 Enable Disable Aztec Code 207 Set Length Range ...

Page 12: ...223 Enable Disable Code One 223 Set Length Range for Code One 224 Chinese Sensible Code 225 Restore Factory Defaults 225 Enable Disable Chinese Sensible Code 225 Set Length Range for Chinese Sensible Code 226 Chinese Sensible Twin Code 227 Chinese Sensible Code Inverse 228 USPS Postnet 229 Restore Factory Defaults 229 Enable Disable USPS Postnet 229 Transmit Check Character 229 USPS Intelligent Ma...

Page 13: ...duction 239 Add a Data Format 239 Programming with Barcodes 239 Programming with Serial Commands 242 Enable Disable Data Formatter 243 Non Match Error Beep 244 Data Format Selection 246 Change Data Format for a Single Scan 247 Clear Data Format 248 Query Data Formats 248 Formatter Command Type 6 250 Send Commands 250 Move Commands 253 Search Commands 255 Miscellaneous Commands 258 Chapter 9 Prefix...

Page 14: ...er Suffix 278 Enable Disable Terminating Character Suffix 278 Set Terminating Character Suffix 278 Chapter 10 Batch Programming 280 Introduction 280 Create a Batch Command 281 Create a Batch Barcode 281 Use Batch Barcode 282 Appendix 283 Digit Barcodes 283 Save Cancel Barcodes 286 Factory Defaults Table 287 AIM ID Table 296 Code ID Table 298 Symbology ID Number 301 ASCII Table 303 ...

Page 15: ...gure general parameters of NVH300 scanner Chapter 4 RS 232 Interface Describes how to configure RS 232 communication parameters Chapter 5 USB Interface Describes how to configure USB communication parameters Chapter 6 Symbologies Lists all compatible symbologies and describes how to configure the relevant parameters Chapter 7 Data Formatter Explains how to customize scanned data with the data form...

Page 16: ...is manual This icon indicates this information requires extra attention from the reader This icon indicates handy tips that can help you use or configure the scanner with ease This icon indicates practical examples that can help you to acquaint yourself with operations ...

Page 17: ...his chapter If you have a scanner at hand make good use of it to develop a better understanding of this manual This chapter is written for normal users maintenance staff and software developers Features of the NVH300 Excellent DPM Decoding Capability Advanced Illumination system Fast Intelligent Learning and Rich Scene Configuration High Protection Industrial Structure Design Model description NLS...

Page 18: ... 5A 1 Quick Guide Paper 1 Qualification Certificate Warranty Card Paper 1 Unpacking Open the package and take out the scanner and its accessories Check to make sure everything on the packing list is present and intact If any contents are damaged or missing please keep the original package and contact your dealer immediately for after sales service ...

Page 19: ...300 DP Good Read Network LED Red LED Device is started successfully Green LED Barcode is decoded successfully NVH300 HD Good Read Network LED Red LED Device is started successfully Green LED Barcode is decoded successfully ...

Page 20: ...6 Dimensions of the Scanner unit mm NVH300 DP NVH300 HD Left View Front View ...

Page 21: ...7 Top View ...

Page 22: ...ype Function 1 KB_CLK I O Keyboard Clock Signal 2 KB_DATA I O Keyboard Data Signal 3 VCC P Power 5V 4 TXD O RS 232 Output 5 RXD I RS 232 Input 6 PC_CLK I O PC Clock Signal 7 PC_DATA I O PC Data Signal 8 GND P Ground 9 D I O USB Signal 10 D I O ...

Page 23: ...g a communication cable USB or RS 232 cable USB USB port on the host device RS 232 RS 232 port on the host device PS 2 PS 2 port on the host device Using USB Cable Connect the scanner to a host device through a USB cable with RJ45 and USB connectors 1 Plug the RJ45 connector into the data port on the scanner 2 Plug the USB connector into the USB port on the host device ...

Page 24: ...a power jack 1 Plug the RJ45 connector into the data port on the scanner 2 Plug the RS 232 connector into the RS 232 port on the host device 3 Plug the supplied power adapter into the power jack on the RS 232 cable Using PS 2 Cable Connect the scanner to a host device through a PS 2 cable with RJ45 and PS 2 connectors ...

Page 25: ...ation cable to NVH300 DP the specific operation steps are as follows 1 Counterclockwise unscrew at the slot of the data line 2 Move the cable sheet in the direction shown by the arrow on the left and open the chuck 3 After inserting the data line into the slot move the cable sheet in the direction shown by the arrow on the right 4 Rotate the screw clockwise and lock the chuck Remove theNVH300 DP C...

Page 26: ...power adapter from mains if there is one 2 Insert the needle into the hole 3 Pull out the cable slowly from the scanner while pressing the needle in 4 Remove the needle 5 Disconnect the cable from the host device Power On Power Off Reboot Power on the scanner Connect the scanner to a host device Then the scanner will be turned on and automatically enter the sleep mode Power off the scanner Remove ...

Page 27: ...e Scanning Instructions When the scanner is in the Level scan mode you can follow the steps below to scan a barcode 1 Press and hold the trigger Then the scanner will project a red cross focusing dashed line 2 Center the aiming pattern on the barcode as shown in the figure below 3 Release the trigger when the aiming pattern goes off If the barcode is decoded successfully the scanner will emit a go...

Page 28: ...14 ...

Page 29: ... connection takes place through several different interface Main Features View and modify the information and setting parameters of online scanner View the general configurations of the offline devices Upgrade the firmware compare the configurations restore to the factory default etc in batch Create print save setting barcodes to a PDF or Word file Support to see how different options affect the r...

Page 30: ...e configured by serial commands HEX sent from the host device Users can design an application program to send those command strings to the scanners to perform device configuration EasySetEX Programming Besides the two methods mentioned above you can conveniently perform scanner configuration through EasySetEX too EasySetEX is a Windows based configuration tool particularly designed for Newland pro...

Page 31: ... description of feature option 4 indicates factory default settings Note included in the programming command indicates permanent setting which means the setting will not be lost by removing power from the scanner or turning off or rebooting it whereas included in the programming command indicates temporary setting which means the setting will be lost by removing power from the scanner or turning o...

Page 32: ...fies the desired parameter within the tag group For example the SubTag for the keyboard layout is CTY Data The value for a feature or parameter setting identified by the Tag and SubTag Suffix ETX HEX 3B 03 2 characters Multiple commands can be issued within one Prefix Suffix sequence For configuration commands only the Tag SubTag and Data fields must be repeated for each command in sequence If an ...

Page 33: ...delay of 100 when the field will only allow 2 digits or an invalid query command ENQ HEX 05 Indicates an invalid Tag or SubTag command When responding the scanner echoes back the command sequence with the status character above inserted directly before each of the punctuation marks the comma or semicolon in the command Examples Example 1 Enable Code 11 set the minimum and maximum lengths to 12 and...

Page 34: ... under programming barcode can be transmitted to the host device Scan the appropriate barcode below to enable or disable the transmission of programming barcode data to the host device SETUPT0 Do Not Transmit Programming Barcode Data SETUPT1 Transmit Programming Barcode Data ...

Page 35: ...21 Illumination ILLSCN1 On ILLSCN0 Off Illumination Color ILLCLR0 Red LED ILLCLR1 White LED ILLCLR2 Red LED and White LED ILLCLR4 Blue LED ...

Page 36: ...n switching Aiming When scanning capturing image the scanner projects an aiming pattern which allows positioning the target barcode within its field of view and thus makes decoding easier Normal The scanner projects an aiming pattern only during barcode scanning capture Always On Aiming pattern is constantly on after the scanner is powered on Off Aiming pattern is off all the time AMLENA1 Normal A...

Page 37: ...23 AMLENA2 Always On ...

Page 38: ...24 Good Read LED The green LED can be programmed to be On or Off to indicate good read GRLENA1 On GRLENA0 Off ...

Page 39: ...om 20ms to 10 000ms GRLDUR20 Short 20ms GRLDUR120 Medium 120ms GRLDUR220 Long 220ms GRLDUR320 Prolonged 320ms GRLDUR Custom 20 10 000ms Set the Good Read LED duration to 800ms 1 Scan the Custom barcode 2 Scan the numeric barcodes 8 0 and 0 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix ...

Page 40: ...n it is powered on Scan the Off barcode if you do not want a power on beep PWBENA1 On PWBENA0 Off Good Read Beep Scanning the Off barcode can turn off the beep that indicates successful decode scanning the On barcode can turn it back on GRBENA1 On GRBENA0 Off ...

Page 41: ...rements from 20ms to 300ms GRBDUR40 Short 40ms GRBDUR80 Medium 80ms GRBDUR120 Long 120ms GRBDUR Custom 20 300ms Set the Good Read Beep duration to 200ms 1 Scan the Custom barcode 2 Scan the numeric barcodes 2 0 and 0 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix ...

Page 42: ...z GRBFRQ1600 Low 1600Hz GRBFRQ2730 Medium 2730Hz GRBFRQ4200 High 4200Hz GRBFRQ Custom 20 20 000Hz Set the Good Read Beep frequency to 2 000Hz 1 Scan the Custom barcode 2 Scan the numeric barcodes 2 0 0 and 0 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix ...

Page 43: ...The number of beeps of a good read can be programmed from 1 to 9 To change the number of beeps scan the barcode below and then scan a numeric barcode 1 9 and the Save barcode The default value is 1 GRBNUM Number of Good Read Beeps ...

Page 44: ...en beeps and it becomes effective when the Number of Good Read Beeps is greater than one GRBITV0 Short GRBITV1 Medium Good Read Vibration You may choose whether or not to let the scanner vibrate when a barcode is successfully read by scanning the appropriate barcode below GRVENA0 Off GRVENA1 On ...

Page 45: ...e decode session timeout Continuous Mode The scanner automatically starts one decode session after another To suspend resume barcode reading simply press the trigger Reread Timeout can avoid undesired rereading of same barcode in a given period of time Pulse Mode When the trigger is pulled and released scanning is activated until a barcode is decoded or the decode session timeout expires The decod...

Page 46: ...r code the aimer is turned on or off according to the configuration of aimer mode When the button is released or the barcode is decoeded successfully the code is stopped When the user drops down the scanner for 3 seconds the scanner will restore the aiming lamp mode to control the aiming lamp to turn on or off SCNMOD0 Level Mode SCNMOD1 Trigger Mode SCNMOD3 Continuous Mode SCNMOD4 Pulse Mode SCNMO...

Page 47: ...33 SCNMOD13 Pre Aiming Mode ...

Page 48: ...n Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix Timeout between Decodes Timeout between Decodes sets the time period between the end of one decode session and the start of next session It is programmable in 1ms increments from 1ms to 10 000ms The default timeout is 500ms This feature is only applicable to the Continuous modes SCNINV Timeout between Decodes Set ...

Page 49: ...ode RRDENA1 Enable Timeout between Decodes RRDENA0 Disable Timeout between Decodes The following parameter sets the time interval between two successive reads on same barcode It is programmable in 1ms increments from 1ms to 3 600 000ms The default setting is 15 000ms RRDDUR Set Reread Timeout Set the reread timeout to 1 000ms 1 Scan the Set Reread Timeout barcode 2 Scan the numeric barcodes 1 0 0 ...

Page 50: ...DENA1 Enable Good Read Delay GRDENA0 Disable Good Read Delay To set the good read delay scan the barcode below then set the delay from 1 to 3 600 000ms by scanning the digit barcode s then scanning the Save barcode from the Appendix GRDDUR Good Read Delay Set the good read delay to 1 000ms 1 Scan the Good Read Delay barcode 2 Scan the numeric barcodes 1 0 0 and 0 from the Digit Barcodes section in...

Page 51: ...ammable in 1ms increments from 1ms to 3 000ms The default timeout is 350ms DETSET Image Decoding Timeout Set the image decoding timeout to 800ms 1 Scan the Image Decoding Timeout barcode 2 Scan the numeric barcodes 8 0 and 0 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix ...

Page 52: ...hen reading barcodes on the screen High Motion Tolerance Mode Select this mode when reading barcodes on moving objects Wide Adaptive Mode Select this mode when application scenarios and code types are diversified EXPLVL0 Normal Mode EXPLVL4 High Motion Tolerance Mode EXPLVL5 Screen Mode EXPLVL6 Wide Adaptive Mode ...

Page 53: ...wer cycle it By default Read Barcode is On Transmit Not Good Read Message Enable When the code failed to decoded and you release the trigger or Decode Session Timeout Not Good Read Message will be sent to the host Disable When the code failed to decoded Not Good Read Message will not be sent to the host NGRENA0 Disable NGRENA1 Enable Edit NGR Message Not Good Read Message supports up to 7 characte...

Page 54: ...decoded This option allows the scanner to narrow its field of view to make sure it reads only those barcodes intended by the user For instance if multiple barcodes are placed closely together specific area decoding in conjunction with appropriate pre defined decoding area will insure that only the desired barcode is read Aiming Bar Code Decoding The scanner only decodes the barcode aimed squarely ...

Page 55: ...0 top 60 bottom 40 left and 60 right of the scanner s field of view You can define the decoding area using the Top of Decoding Area Bottom of Decoding Area Left of Decoding Area and Right of Decoding Area barcodes as well as numeric barcode s that represent s a desired percentage 0 100 The value of Bottom must be greater than that of Top the value of Right must be greater than that of Left CADTOP ...

Page 56: ...he Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan the Bottom of Decoding Area barcode 5 Scan the numeric barcodes 4 and 5 from the Digit Barcodes section in Appendix 6 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 7 Scan the Top of Decoding Area barcode 8 Scan the numeric barcodes 1 and 0 from the Digit Barcodes section in Appendix 9 Scan the Save b...

Page 57: ...the Digit Barcodes section in Appendix 15 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 16 Scan the Left of Decoding Area barcode 17 Scan the numeric barcodes 1 and 5 from the Digit Barcodes section in Appendix 18 Scan the Save barcode from the Save Cancel Barcodes section in Appendix Image Flipping MIRROR0 Do Not Flip MIRROR1 Flip Horizontally Example of image not flippe...

Page 58: ...tore the scanner to the factory defaults You may need to reset all parameters to the factory defaults when scanner is not properly configured so that it fails to decode barcodes you forget previous configuration and want to avoid its impact FACDEF Restore All Factory Defaults ...

Page 59: ...m defaults Scanning the Save as Custom Defaults barcode can set the current settings as custom defaults Custom defaults are stored in the non volatile memory CUSSAV Save as Custom Defaults CUSDEF Restore All Custom Defaults Restoring the scanner to the factory defaults will not remove the custom defaults from the scanner ...

Page 60: ...ding product name firmware version decoder version hardware version product serial number OEM serial number and manufacturing date will be sent to the host device QRYSYS Query Scanner Information Query Product Name QRYPDN Query Product Name Query Firmware Version QRYFWV Query Firmware Version ...

Page 61: ...uery Decoder Version QRYDCV Query Decoder Version Query Hardware Version QRYHWV Query Hardware Version Query Serial Number QRYPSN Query Serial Number Query Manufacturing Date QRYDAT Query Manufacturing Date ...

Page 62: ...48 ...

Page 63: ...adle is connected to the RS 232 port of a host device you need to set communication parameters including baud rate parity check data bit and stop bit on the cradle to match the host device so that two devices can communicate with each other INTERF0 RS 232 ...

Page 64: ...50 Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the host requirements 232BAD8 115200 232BAD7 57600 232BAD6 38400 232BAD5 19200 232BAD4 14400 ...

Page 65: ... type to match the host requirements Odd Parity If the data contains an odd number of 1 bits the parity bit value is set to 0 Even Parity If the data contains an even number of 1 bits the parity bit value is set to 0 None Select this option when no parity bit is required 232PAR0 None ...

Page 66: ...52 232PAR1 Even Parity 232PAR2 Odd Parity ...

Page 67: ...Data Bits Stop Bit The stop bit s at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream Set the number of stop bits to match the host requirements 232STP0 1 Stop Bit 232STP1 2 Stop Bits ...

Page 68: ...vice When the cradle is not ready for receiving it will set RTS signal to low level When sending device such as PC detects it it will not send data to the cradle any more to prevent data loss If this feature is disabled reception transmission of serial data will not be influenced by RTS CTS signal 232AFL0 Disable Hardware Auto Flow Control 232AFL1 Enable Hardware Auto Flow Control Before enabling ...

Page 69: ...de data could be entered by the virtual keyboard directly and it is also convenient for the host device to receive data USB CDC It is compliant with the standard USB CDC class specifications defined by the USB IF and allows the host device to receive data in the way as a serial port does A driver is needed when using this feature When the scanner is connected to both USB and RS 232 ports on a host...

Page 70: ...y scanning the barcode below The cradle s transmission will be simulated as USB keyboard input The Host receives keystrokes on the virtual keyboard It works on a Plug and Play basis and no driver is required INTERF3 USB HID Keyboard If the host device allows keyboard input then no extra software is needed for HID Keyboard input ...

Page 71: ...try Keyboard Types Keyboard layouts vary from country to country The default setting is U S keyboard KBWCTY0 U S English KBWCTY1 Belgium KBWCTY2 Brazil KBWCTY3 Canada French KBWCTY4 Czechoslovakia KBWCTY5 Denmark ...

Page 72: ...58 KBWCTY6 Finland Swedish KBWCTY7 France KBWCTY8 Germany Austria KBWCTY9 Greece KBWCTY10 Hungary KBWCTY11 Israel Hebrew KBWCTY12 Italy ...

Page 73: ...59 KBWCTY13 Latin America South America KBWCTY14 Netherlands Dutch KBWCTY15 Norway KBWCTY16 Poland KBWCTY17 Portugal KBWCTY18 Romania KBWCTY19 Russia ...

Page 74: ...60 KBWCTY21 Slovakia KBWCTY22 Spain KBWCTY23 Sweden KBWCTY24 Switzerland German KBWCTY25 Turkey_F KBWCTY26 Turkey_Q KBWCTY27 UK ...

Page 75: ...in barcode data may be unavailable on the selected keyboard As a result the scanner fails to transmit the unknown characters Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected KBWBUC0 Do Not Beep on Unknown Character KBWBUC1 Beep on Unknown Character ...

Page 76: ...ge with which the barcodes were created and to turn Unicode Encoding On or Off depending on the encoding used by the application software KBWALT0 Emulate ALT Keypad OFF KBWALT1 Emulate ALT Keypad ON Since sending a character involves multiple keystroke emulations this method appears less efficient Supposing Emulate ALT Keypad is ON Unicode Encoding is Off and Code Page 1252 West European Latin is ...

Page 77: ...code page with which the barcodes were created by scanning the appropriate barcode below For PDF417 QR Code Aztec and Data Matrix besides setting the code page you also need to set the character encoding in the Character Encoding section in Chapter 7 This feature is only effective when Emulate ALT Keypad is turned on KBWCPG0 Code Page 1252 West European Latin KBWCPG1 Code Page 1251 Cyrillic KBWCPG...

Page 78: ...Hebrew KBWCPG6 Code Page 1256 Arabic KBWCPG7 Code Page 1257 Baltic KBWCPG8 Code Page 1258 Vietnamese KBWCPG9 Code Page 936 Simplified Chinese GB2312 GBK KBWCPG10 Code Page 950 Traditional Chinese Big5 KBWCPG11 Code Page 874 Thai ...

Page 79: ...65 KBWCPG12 Code Page 932 Japanese Shift JIS ...

Page 80: ...a For instance Microsoft Office Word uses Unicode encoding and therefore you should turn Unicode Encoding on whereas Microsoft Office Excel or Notepad uses Code Page encoding and therefore you should turn Unicode Encoding off This feature is only effective when Emulate ALT Keypad is turned on KBWCPU0 Off KBWCPU1 On ...

Page 81: ...KBWFKM1 Ctrl ASCII Mode If Ctrl ASCII Mode is selected and other parameters of USB HID Keyboard adopt factory defaults barcode data A HT i e Horizontal Tab F 0x41 0x09 0x46 is sent as below A Keystroke A HT Ctrl Make Keystroke I Ctrl Break F Keystroke F For some text editors Ctrl I means italic convert So the output may be AF Emulate ALT Keypad ON prevails over Ctrl ASCII Mode ...

Page 82: ...l G BS 08 Left Arrow Ctrl H HT 09 Horizontal Tab Ctrl I LF 0A Down Arrow Ctrl J VT 0B Vertical Tab Ctrl K FF 0C Delete Ctrl L CR 0D Enter Ctrl M SO 0E Insert Ctrl N SI 0F Esc Ctrl O DLE 10 F11 Ctrl P DC1 11 Home Ctrl Q DC2 12 PrintScreen Ctrl R DC3 13 Backspace Ctrl S DC4 14 tab shift Ctrl T NAK 15 F12 Ctrl U SYN 16 F1 Ctrl V ETB 17 F2 Ctrl W CAN 18 F3 Ctrl X EM 19 F4 Ctrl Y SUB 1A F5 Ctrl Z ESC 1...

Page 83: ...es Country Ctrl ASCII United States Ctrl Ctrl Ctrl Ctrl 6 Ctrl Belgium Ctrl Ctrl Ctrl Ctrl 6 Ctrl Scandinavia Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl France Ctrl Ctrl 8 Ctrl Ctrl 6 Ctrl Germany Ctrl à Ctrl Ctrl 6 Ctrl Italy Ctrl Ctrl Ctrl 6 Ctrl Switzerland Ctrl Ctrl Ctrl 6 Ctrl United Kingdom Ctrl Ctrl Ctrl Ctrl 6 Ctrl Denmark Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl Norway Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl Spain Ctrl...

Page 84: ...on can invert upper and lower case characters contained in barcode data This inversion occurs regardless of the state of Caps Lock key on the host device s keyboard KBWCAP0 Caps Lock OFF KBWCAP1 Caps Lock ON Emulate ALT Keypad ON Convert All to Upper Case Convert All to Lower Case prevails over Caps Lock ON When the Caps Lock ON feature is selected barcode data AbC is transmitted as aBc ...

Page 85: ...S0 No Case Conversion KBWCAS1 Convert All to Upper Case KBWCAS2 Convert All to Lower Case When the Convert All to Lower Case feature is enabled barcode data AbC is transmitted as abc If Emulate ALT Keypad ON is selected Convert All to Lower Case and Convert All to Upper Case do not function Emulate Numeric Keypad ...

Page 86: ...s equivalent on the host device If Num Lock on the host device is turned off the output of simulated numeric keypad is function key instead of number Do Not Emulate Numeric Keypad 2 Sending and is emulated as keystroke s on main keyboard Emulate Numeric Keypad 2 Sending and is emulated as keystroke s on numeric keypad KBWNUM0 Do Not Emulate Numeric Keypad 1 KBWNUM1 Emulate Numeric Keypad 1 KBWNCH0...

Page 87: ... is enabled if Num Lock on the host device is ON A4 5 is transmitted as A4 5 if Num Lock on the host device is OFF A4 5 is transmitted as A 1 A is sent on main keyboard 2 4 is sent as the function key Cursor Move to Left 3 is sent on main keyboard 4 5 is not sent as it does not correspond to any function key ...

Page 88: ...Polling Rate This parameter specifies the polling rate for a USB keyboard If the Host drops characters change the polling rate to a bigger value KBWPOR0 1ms KBWPOR1 2ms KBWPOR2 3ms KBWPOR3 4ms KBWPOR4 5ms ...

Page 89: ...75 KBWPOR5 6ms KBWPOR6 7ms KBWPOR7 8ms KBWPOR8 9ms KBWPOR9 10ms ...

Page 90: ...interface is recommended for new application programs It can send up to 56 characters in a single USB report and appears more efficient than keyboard emulation Features HID based no custom driver required Way more efficient in communication than keyboard emulation and traditional RS 232 interface Note HID POS does not require a custom driver However a HID interface on Windows 98 does All HID inter...

Page 91: ...ed to send commands to the scanner All programming commands can be used Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 0x04 1 Length of command 2 62 Command 63 Command continued VID PID USB uses VID Vendor ID and PID Product ID to identify and locate a device The VID is assigned by USB Implementers Forum Newland s vendor ID is 1EAB Hex A range of PIDs are used for each Newland product family Every PID conta...

Page 92: ...78 Product Interface PID Hex PID Dec HR42 USB HID Keyboard 1E03 7683 USB CDC 1E06 7686 USB HID POS 1E10 7696 ...

Page 93: ...79 ...

Page 94: ...identify various symbologies It is recommended to disable those that are rarely used to increase the efficiency of the scanner Global Settings Enable Disable All Symbologies If the Disable All Symbologies feature is enabled the scanner will not be able to read any non programming barcodes except the programming barcodes ALLENA1 Enable All Symbologies ALLENA0 Disable All Symbologies ...

Page 95: ...e Disable 1D Symbologies ALL1DC1 Enable 1D Symbologies ALL1DC0 Disable 1D Symbologies Enable Disable 2D Symbologies ALL2DC1 Enable 2D Symbologies ALL2DC0 Disable 2D Symbologies Enable Disable Postal Symbologies ...

Page 96: ... specifications and be placed closely together There are 3 options for reading 1D twin code Single 1D Code Only Read either 1D code Twin 1D Code Only Read both 1D codes Transmission sequence upper 1D code followed by lower 1D code Both Single Twin Read both 1D codes If successful transmit as twin 1D code only Otherwise try single 1D code only A1DDOU0 Single 1D Code Only A1DDOU2 Twin 1D Code Only A...

Page 97: ...83 Enhance Poor Quality 1D Barcode Decoding ALL1DE0 Off ALL1DE1 On ...

Page 98: ...e Factory Defaults of Code 128 Enable Disable Code 128 128ENA1 Enable Code 128 128ENA0 Disable Code 128 If the scanner fails to identify Code 128 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Code 128 barcode ...

Page 99: ...des with either the minimum or maximum length If minimum length is same as maximum length only Code 128 barcodes with that length are to be decoded Set the scanner to decode Code 128 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes ...

Page 100: ...isable EAN 8 If the scanner fails to identify EAN 8 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable EAN 8 barcode Transmit Check Character EAN 8 is 8 digits in length with the last one as its check character used to verify the integrity of the data EA8CHK2 Transmit EAN 8 Check Character ...

Page 101: ... part circled by red dotted line is a two digit add on code EA8AD20 Disable 2 Digit Add On Code EA8AD21 Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner decodes EAN 8 and ignores the add on code when presented with an EAN 8 plus 2 digit add on barcode It can also decode EAN 8 barcodes without 2 digit add on codes Enable 2 Digit Add On Code The scanner decodes a mix of EAN 8 barco...

Page 102: ...able 5 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 8 and ignores the add on code when presented with an EAN 8 plus 5 digit add on barcode It can also decode EAN 8 barcodes without 5 digit add on codes Enable 5 Digit Add On Code The scanner decodes a mix of EAN 8 barcodes with and without 5 digit add on codes Add On Code Required When EAN 8 Add On Code Required is selected...

Page 103: ... no space EA8SEP0 Off EA8SEP1 On Convert EAN 8 to EAN 13 Convert EAN 8 to EAN 13 Convert EAN 8 decoded data to EAN 13 format before transmission After conversion the data follows EAN 13 format and is affected by EAN 13 programming selections e g Check Character Do Not Convert EAN 8 to EAN 13 EAN 8 decoded data is transmitted as EAN 8 data without conversion EA8EXP0 Do Not Convert EAN 8 to EAN 13 ...

Page 104: ...90 EA8EXP1 Convert EAN 8 to EAN 13 ...

Page 105: ...re the Factory Defaults of EAN 13 Enable Disable EAN 13 E13ENA1 Enable EAN 13 E13ENA0 Disable EAN 13 If the scanner fails to identify EAN 13 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable EAN 13 barcode ...

Page 106: ...ew one In the example below the part surrounded by blue dotted line is an EAN 13 barcode while the part circled by red dotted line is a two digit add on code E13AD20 Disable 2 Digit Add On Code E13AD21 Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code when presented with an EAN 13 plus 2 digit add on barcode It can also decode EAN 13 barc...

Page 107: ...93 2 digit add on codes Enable 2 Digit Add On Code The scanner decodes a mix of EAN 13 barcodes with and without 2 digit add on codes ...

Page 108: ... 5 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code when presented with an EAN 13 plus 5 digit add on barcode It can also decode EAN 13 barcodes without 5 digit add on codes Enable 5 Digit Add On Code The scanner decodes a mix of EAN 13 barcodes with and without 5 digit add on codes Add On Code Required When EAN 13 Add On Code Required is selecte...

Page 109: ...igit on EAN 13 barcodes that begin with 290 The following settings can be programmed Require Add On Code All EAN 13 barcodes that begin with 290 must have a 2 digit or 5 digit add on code The EAN 13 barcode with the add on code is then transmitted If the required add on code is not found the EAN 13 barcode is discarded Do Not Require Add On Code If you have selected Require Add On Code and you wan...

Page 110: ... The EAN 13 barcode with the add on code is then transmitted If the required add on code is not found the EAN 13 barcode is discarded Do Not Require Add On Code If you have selected Require Add On Code and you want to disable this feature scan Do Not Require Add On Code EAN 13 barcodes are handled depending on your selection for the Add On Code Required feature E133780 Do Not Require Add On Code E...

Page 111: ...uire Add On Code EAN 13 Beginning with 434 439 Add On Code Required This setting programs the scanner to require an add on code 2 digit or 5 digit on EAN 13 barcodes that begin with a 434 or 439 The following settings can be programmed Require Add On Code All EAN 13 barcodes that begin with a 434 or 439 must have a 2 digit or 5 digit add on code The EAN 13 barcode with the add on code is then tran...

Page 112: ...n your selection for the Add On Code Required feature E139770 Do Not Require Add On Code E139771 Require Add On Code EAN 13 Beginning with 978 Add On Code Required This setting programs the scanner to require an add on code 2 digit or 5 digit on EAN 13 barcodes that begin with 978 The following settings can be programmed Require Add On Code All EAN 13 barcodes that begin with 978 must have a 2 dig...

Page 113: ...5 digit add on code The EAN 13 barcode with the add on code is then transmitted If the required add on code is not found the EAN 13 barcode is discarded Do Not Require Add On Code If you have selected Require Add On Code and you want to disable this feature scan Do Not Require Add On Code EAN 13 barcodes are handled depending on your selection for the Add On Code Required feature E139790 Do Not Re...

Page 114: ...100 Enable Disable UPC E UPEENA1 Enable UPC E UPEENA0 Disable UPC E UPEEN01 Enable UPC E0 UPEEN00 Disable UPC E0 UPEEN11 Enable UPC E1 UPEEN10 Disable UPC E1 ...

Page 115: ...Character 2 Digit Add On Code A UPC E barcode can be augmented with a two digit add on code to form a new one In the example below the part surrounded by blue dotted line is a UPC E barcode while the part circled by red dotted line is a two digit add on code UPEAD20 Disable 2 Digit Add On Code UPEAD21 Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner decodes UPC E and ignores the ...

Page 116: ...In the example below the part surrounded by blue dotted line is a UPC E barcode while the part circled by red dotted line is a five digit add on code UPEAD50 Disable 5 Digit Add On Code UPEAD51 Enable 5 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC E and ignores the add on code when presented with a UPC E plus 5 digit add on barcode It can also decode UPC E barcodes without...

Page 117: ...C E barcodes that contain add on codes UPEREQ1 UPC E Add On Code Required UPEREQ0 UPC E Add On Code Not Required Add On Code Separator When this feature is on there is a space between the data from the barcode and the data from the add on code When turned off there is no space UPESEP0 Off UPESEP1 On ...

Page 118: ...or USA or transmit no preamble UPEPRE1 System Character UPEPRE0 No Preamble UPEPRE2 System Character Country Code Convert UPC E to UPC A Convert UPC E to UPC A Convert UPC E zero suppressed decoded data to UPC A format before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Character Do Not Convert UPC E to UPC A UPC E d...

Page 119: ...PC A UPAENA1 Enable UPC A UPAENA0 Disable UPC A If the scanner fails to identify UPC A barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable UPC A barcode Transmit Check Character UPC A is 13 digits in length with the last one as its check character used to verify the integrity of the data ...

Page 120: ...a two digit add on code to form a new one In the example below the part surrounded by blue dotted line is a UPC A barcode while the part circled by red dotted line is a two digit add on code UPAAD20 Disable 2 Digit Add On Code UPAAD21 Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner decodes UPC A and ignores the add on code when ...

Page 121: ...d with a UPC A plus 2 digit add on barcode It can also decode UPC A barcodes without 2 digit add on codes Enable 2 Digit Add On Code The scanner decodes a mix of UPC A barcodes with and without 2 digit add on codes ...

Page 122: ...able 5 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC A and ignores the add on code when presented with a UPC A plus 5 digit add on barcode It can also decode UPC A barcodes without 5 digit add on codes Enable 5 Digit Add On Code The scanner decodes a mix of UPC A barcodes with and without 5 digit add on codes Add On Code Required When UPC A Add On Code Required is selected ...

Page 123: ...off there is no space UPASEP0 Off UPASEP1 On Transmit Preamble Character Preamble characters Country Code and System Character can be transmitted as part of a UPC A barcode Select one of the following options for transmitting UPC A preamble to the host device transmit system character only transmit system character and country code 0 for USA or transmit no preamble UPAPRE0 No Preamble ...

Page 124: ...110 UPAPRE1 System Character UPAPRE2 System Character Country Code ...

Page 125: ...terleaved 2 of 5 Enable Disable Interleaved 2 of 5 I25ENA1 Enable Interleaved 2 of 5 I25ENA0 Disable Interleaved 2 of 5 If the scanner fails to identify Interleaved 2 of 5 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Interleaved 2 of 5 barcode ...

Page 126: ...barcodes with either the minimum or maximum length If minimum length is same as maximum length only Interleaved 2 of 5 barcodes with that length are to be decoded Set the scanner to decode Interleaved 2 of 5 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from ...

Page 127: ...r algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted Since Interleaved 2 of 5 must always have an even number of digits a zero may need to be added as the first digit when the check character is added The check character is automatically generated when making Interleaved 2 of 5 barcodes I25CHK0 Disable I25CHK1 Do Not Transmit Check Character A...

Page 128: ...le Febraban I25FBB1 Enable Febraban Do Not Expand I25FBB2 Enable Febraban Expand Febraban Barcode Transmit Delay Febraban Transmit Delay per Character FEBSEN0 Disable FEBSEN1 Enable Febraban Custom Transmit Delay per Character ...

Page 129: ...115 FEBSDT0 0ms FEBSDT5 5ms FEBSDT10 10ms FEBSDT15 15ms FEBSDT20 20ms FEBSDT25 25ms FEBSDT30 30ms ...

Page 130: ...116 FEBSDT35 35ms FEBSDT40 40ms FEBSDT45 45ms FEBSDT50 50ms FEBSDT55 55ms FEBSDT60 60ms FEBSDT65 65ms ...

Page 131: ...117 FEBSDT70 70ms FEBSDT75 75ms ...

Page 132: ...racter as the check character the ITF 14 configurations shall take precedence over the Interleaved 2 of 5 settings Restore Factory Defaults I14DEF Restore the Factory Defaults of ITF 14 Enable Disable ITF 14 I14ENA0 Disable ITF 14 I14ENA1 Enable ITF 14 But Do Not Transmit Check Character I14ENA2 Enable ITF 14 and Transmit Check Character An example of the ITF 14 priority principle when ITF 14 is e...

Page 133: ...119 scanner only decodes Interleaved 2 of 5 barcodes with a length of 14 characters and the last character as the check character ...

Page 134: ...arcodes with a length of 6 characters and the last character as the check character the ITF 6 configurations shall take precedence over the Interleaved 2 of 5 settings Restore Factory Defaults IT6DEF Restore the Factory Defaults of ITF 6 Enable Disable ITF 6 IT6ENA0 Disable ITF 6 IT6ENA1 Enable ITF 6 But Do Not Transmit Check Character IT6ENA2 Enable ITF 6 and Transmit Check Character ...

Page 135: ...of the ITF 6 priority principle when ITF 6 is enabled and Interleaved 2 of 5 is disabled the scanner only decodes Interleaved 2 of 5 barcodes with a length of 6 characters and the last character as the check character ...

Page 136: ...faults of Matrix 2 of 5 Enable Disable Matrix 2 of 5 M25ENA1 Enable Matrix 2 of 5 M25ENA0 Disable Matrix 2 of 5 If the scanner fails to identify Matrix 2 of 5 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Matrix 2 of 5 barcode ...

Page 137: ...rcodes with either the minimum or maximum length If minimum length is same as maximum length only Matrix 2 of 5 barcodes with that length are to be decoded Set the scanner to decode Matrix 2 of 5 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Can...

Page 138: ...ies with the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted Since Matrix 2 of 5 must always have an even number of digits a zero may need to be added as the first digit when the check character is added The check character is automatically generated when making Matrix 2 of 5 barcodes M25CHK0 Disable M25CHK1 Do Not Transmit ...

Page 139: ...125 characters including the check character cannot be read ...

Page 140: ... the Factory Defaults of Code 39 Enable Disable Code 39 C39ENA1 Enable Code 39 C39ENA0 Disable Code 39 If the scanner fails to identify Code 39 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Code 39 barcode ...

Page 141: ...des with either the minimum or maximum length If minimum length is same as maximum length only Code 39 barcodes with that length are to be decoded Set the scanner to decode Code 39 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 142: ...r Verification The scanner checks the integrity of all Code 39 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted C39CHK0 Disable C39CHK1 Do Not Transmit Check Character After Verification C39CHK2 Transmit Check Character After Verification If the Do Not Transmit Check Characte...

Page 143: ...129 including the check character cannot be read ...

Page 144: ...art stop characters by scanning the appropriate barcode below C39TSC0 Do Not Transmit Start Stop Character C39TSC1 Transmit Start Stop Character Enable Disable Code 39 Full ASCII The scanner can be configured to identify all ASCII characters by scanning the appropriate barcode below C39ASC0 Disable Code 39 Full ASCII C39ASC1 Enable Code 39 Full ASCII ...

Page 145: ...st be enabled and Code 39 check character verification must be disabled for this parameter to function C39E320 Disable Code 32 C39E321 Enable Code 32 Code 32 Prefix You may scan the appropriate barcode below to enable or disable adding the prefix character A to all Code 32 barcodes Code 32 must be enabled for this parameter to function C39S320 Disable Code 32 Prefix C39S321 Enable Code 32 Prefix ...

Page 146: ...to function C39T320 Do Not Transmit Code 32 Start Stop Character C39T321 Transmit Code 32 Start Stop Character Transmit Code 32 Check Character Code 32 must be enabled for this parameter to function C39C320 Do Not Transmit Code 32 Check Character C39C321 Transmit Code 32 Check Character ...

Page 147: ... the Factory Defaults of Codabar Enable Disable Codabar CBAENA1 Enable Codabar CBAENA0 Disable Codabar If the scanner fails to identify Codabar barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Codabar barcode ...

Page 148: ...des with either the minimum or maximum length If minimum length is same as maximum length only Codabar barcodes with that length are to be decoded Set the scanner to decode Codabar barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 149: ...r Verification The scanner checks the integrity of all Codabar barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted CBACHK0 Disable CBACHK1 Do Not Transmit Check Character After Verification CBACHK2 Transmit Check Character After Verification If the Do Not Transmit Check Characte...

Page 150: ...136 including the check character cannot be read ...

Page 151: ...ansmit the start stop characters by scanning the appropriate barcode below CBATSC0 Do Not Transmit Start Stop Character CBATSC1 Transmit Start Stop Character CBASCF0 ABCD ABCD as the Start Stop Character CBASCF1 ABCD TN E as the Start Stop Character CBASCF2 abcd abcd as the Start Stop Character ...

Page 152: ...138 CBASCF3 abcd tn e as the Start Stop Character ...

Page 153: ... the Factory Defaults of Code 93 Enable Disable Code 93 C93ENA1 Enable Code 93 C93ENA0 Disable Code 93 If the scanner fails to identify Code 93 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Code 93 barcode ...

Page 154: ...des with either the minimum or maximum length If minimum length is same as maximum length only Code 93 barcodes with that length are to be decoded Set the scanner to decode Code 93 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 155: ...acter After Verification The scanner checks the integrity of all Code 93 barcodes to verify that the data complies with the check character algorithm Barcodes passing the checks will be transmitted whereas those failing them will not be transmitted C93CHK0 Disable C93CHK1 Do Not Transmit Check Character After Verification C93CHK2 Transmit Check Character After Verification If the Do Not Transmit C...

Page 156: ...142 characters including the two check characters cannot be read ...

Page 157: ...faults of China Post 25 Enable Disable China Post 25 CHPENA1 Enable China Post 25 CHPENA0 Disable China Post 25 If the scanner fails to identify China Post 25 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable China Post 25 barcode ...

Page 158: ...rcodes with either the minimum or maximum length If minimum length is same as maximum length only China Post 25 barcodes with that length are to be decoded Set the scanner to decode China Post 25 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Can...

Page 159: ...r After Verification The scanner checks the integrity of all China Post 25 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted CHPCHK0 Disable CHPCHK1 Do Not Transmit Check Character After Verification CHPCHK2 Transmit Check Character After Verification If the Do Not Transmit Ch...

Page 160: ...146 characters including the check character cannot be read ...

Page 161: ...faults GS1DEF Restore the Factory Defaults of GS1 128 Enable Disable GS1 128 GS1ENA1 Enable GS1 128 GS1ENA0 Disable GS1 128 If the scanner fails to identify GS1 128 barcodes you may first try this solution by scanning the Enable GS1 128 barcode ...

Page 162: ...des with either the minimum or maximum length If minimum length is same as maximum length only GS1 128 barcodes with that length are to be decoded Set the scanner to decode GS1 128 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 163: ... AIMDEF Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 AIMENA1 Enable AIM128 AIMENA0 Disable AIM 128 If the scanner fails to identify AIM 128 barcodes you may first try this solution by scanning the Enable AIM 128 barcode ...

Page 164: ...des with either the minimum or maximum length If minimum length is same as maximum length only GS1 128 barcodes with that length are to be decoded Set the scanner to decode AIM 128 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 165: ...TDEF Restore the Factory Defaults of ISBT 128 Enable Disable ISBT 128 IBTENA1 Enable ISBT 128 IBTENA0 Disable ISBT 128 If the scanner fails to identify ISBT 128 barcodes you may first try this solution by scanning the Enable ISBT 128 barcode ...

Page 166: ...able GS1 Databar RSSENA1 Enable GS1 Databar RSSENA0 Disable GS1 Databar If the scanner fails to identify GS1 Databar barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable GS1 Databar barcode Transmit Application Identifier 01 RSSTAI1 Transmit Application Identifier 01 ...

Page 167: ...ults CPTDEF Restore the Factory Defaults of GS1 Composite Enable Disable GS1 Composite CPTENA1 Enable GS1 Composite CPTENA0 Disable GS1 Composite If the scanner fails to identify GS1 Composite barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable GS1 Composite barcode ...

Page 168: ...able UPC EAN Composite CPTUPC1 Enable UPC EAN Composite CPTUPC0 Disable UPC EAN Composite Code 11 Restore Factory Defaults C11DEF Restore the Factory Defaults of Code 11 Enable Disable Code 11 C11ENA1 Enable Code 11 ...

Page 169: ...155 C11ENA0 Disable Code 11 If the scanner fails to identify Code 11 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Code 11 barcode ...

Page 170: ...des with either the minimum or maximum length If minimum length is same as maximum length only Code 11 barcodes with that length are to be decoded Set the scanner to decode Code 11 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 171: ...lated values used to verify the integrity of the data If the Disable option is enabled the scanner transmits Code 11 barcodes as is C11CHK0 Disable C11CHK1 One Check Character MOD11 C11CHK2 Two Check Characters MOD11 MOD11 C11CHK3 Two Check Characters MOD11 MOD9 C11CHK4 One Check Character MOD11 Len 10 Two Check Characters MOD11 MOD11 Len 10 ...

Page 172: ...158 C11CHK5 One Check Character MOD11 Len 10 Two Check Characters MOD11 MOD9 Len 10 ...

Page 173: ...aracter option Code 11 barcodes with a length that is less than the configured minimum length after having the check character s excluded will not be decoded For example when the One Check Character MOD11 and Do Not Transmit Check Character options are enabled and the minimum length is set to 4 Code 11 barcodes with a total length of 4 characters including the check character cannot be read ...

Page 174: ...160 ISBN Restore Factory Defaults ISBDEF Restore the Factory Defaults of ISBN Enable Disable ISBN ISBENA1 Enable ISBN ISBENA0 Disable ISBN ...

Page 175: ...161 Set ISBN Format ISBT101 ISBN 10 ISBT100 ISBN 13 ...

Page 176: ...162 ISSN Restore Factory Defaults ISSDEF Restore the Factory Defaults of ISSN Enable Disable ISSN ISSENA1 Enable ISSN ISSENA0 Disable ISSN ...

Page 177: ... the Factory Defaults of Industrial 25 Enable Disable Industrial 25 L25ENA1 Enable Industrial 25 L25ENA0 Disable Industrial 25 If the scanner fails to identify Industrial 25 barcodes you may first try this solution by scanning the Enable Industrial 25 barcode ...

Page 178: ...rcodes with either the minimum or maximum length If minimum length is same as maximum length only Industrial 25 barcodes with that length are to be decoded Set the scanner to decode Industrial 25 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Can...

Page 179: ...r After Verification The scanner checks the integrity of all Industrial 25 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted L25CHK0 Disable L25CHK1 Do Not Transmit Check Character After Verification L25CHK2 Transmit Check Character After Verification If the Do Not Transmit Ch...

Page 180: ...166 characters including the check character cannot be read ...

Page 181: ...store the Factory Defaults of Standard 25 Enable Disable Standard 25 S25ENA1 Enable Standard 25 S25ENA0 Disable Standard 25 If the scanner fails to identify Standard 25 barcodes you may first try this solution by scanning the Enable Standard 25 barcode ...

Page 182: ...codes with either the minimum or maximum length If minimum length is same as maximum length only Standard 25 barcodes with that length are to be decoded Set the scanner to decode Standard 25 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel B...

Page 183: ...nner checks the integrity of all Standard 25 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted S25CHK0 Disable S25CHK1 Do Not Transmit Check Character After Verification S25CHK2 Transmit Check Character After Verification If the Do Not Transmit Check Character After Verificati...

Page 184: ...170 COOP 25 Restore Factory Defaults COPDEF Restore the Factory Defaults of COOP 25 Enable Disable COOP 25 COPENA1 Enable COOP 25 COPENA0 Disable COOP 25 ...

Page 185: ...des with either the minimum or maximum length If minimum length is same as maximum length only COOP 25 barcodes with that length are to be decoded Set the scanner to decode COOP 25 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 186: ...t the data complies with the check character algorithm Barcodes passing the check will be transmitted except the last digit whereas those failing it will not be transmitted Enable And Transmit Check Character The scanner checks the integrity of all COOP 25 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those faili...

Page 187: ...e Factory Defaults D14DEF Restore the Factory Defaults of Deutsche 14 Enable Disable Deutsche 14 D14ENA1 Enable Deutsche 14 But Do Not Transmit Check Digit D14ENA2 Enable Deutsche 14 and Transmit Check Digit D14ENA0 Disable ...

Page 188: ...e Factory Defaults D12DEF Restore the Factory Defaults of Deutsche 12 Enable Disable Deutsche 12 D12ENA1 Enable Deutsche 12 But Do Not Transmit Check Digit D12ENA2 Enable Deutsche 12 and Transmit Check Digit D12ENA0 Disable ...

Page 189: ... the Factory Defaults of Plessey Enable Disable Plessey PLYENA1 Enable Plessey PLYENA0 Disable Plessey If the scanner fails to identify Plessey barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Plessey barcode ...

Page 190: ...des with either the minimum or maximum length If minimum length is same as maximum length only Plessey barcodes with that length are to be decoded Set the scanner to decode Plessey barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 191: ...r After Verification The scanner checks the integrity of all Plessey barcodes to verify that the data complies with the check character algorithm Barcodes passing the checks will be transmitted whereas those failing them will not be transmitted PLYCHK0 Disable PLYCHK1 Do Not Transmit Check Character After Verification PLYCHK2 Transmit Check Character After Verification If the Do Not Transmit Check...

Page 192: ...178 including the check characters cannot be read ...

Page 193: ...store the Factory Defaults of MSI Plessey Enable Disable MSI Plessey MSIENA1 Enable MSI Plessey MSIENA0 Disable MSI Plessey If the scanner fails to identify MSI Plessey barcodes you may first try this solution by scanning the Enable MSI Plessey barcode ...

Page 194: ...codes with either the minimum or maximum length If minimum length is same as maximum length only MSI Plessey barcodes with that length are to be decoded Set the scanner to decode MSI Plessey barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel B...

Page 195: ...st one or two characters which are calculated values used to verify the integrity of the data If the Disable option is enabled the scanner transmits MSI Plessey barcodes as is MSICHK0 Disable MSICHK1 One Check Character MOD10 MSICHK2 Two Check Characters MOD10 MOD10 MSICHK3 Two Check Characters MOD10 MOD11 ...

Page 196: ...aracter option MSI Plessey barcodes with a length that is less than the configured minimum length after having the check character s excluded will not be decoded For example when the One Check Character MOD10 and Do Not Transmit Check Character options are enabled and the minimum length is set to 4 MSI Plessey barcodes with a total length of 4 characters including the check character cannot be rea...

Page 197: ... C49DEF Restore the Factory Defaults of Code 49 Enable Disable Code 49 C49ENA1 Enable Code 49 C49ENA0 Disable Code 49 If the scanner fails to identify Code 49 barcodes you may first try this solution by scanning the Enable Code 49 barcode ...

Page 198: ...des with either the minimum or maximum length If minimum length is same as maximum length only Code 49 barcodes with that length are to be decoded Set the scanner to decode Code 49 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 199: ...KDEF Restore the Factory Defaults of Code 16K Enable Disable Code 16K 16KENA1 Enable Code 16K 16KENA0 Disable Code 16K If the scanner fails to identify Code 16K barcodes you may first try this solution by scanning the Enable Code 16K barcode ...

Page 200: ...des with either the minimum or maximum length If minimum length is same as maximum length only Code 16K barcodes with that length are to be decoded Set the scanner to decode Code 16K barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes ...

Page 201: ...PDEF Restore the Factory Defaults of Telepen Enable Disable Telepen TLPENA1 Enable Code Telepen TLPENA0 Disable Telepen If the scanner fails to identify Code 16K barcodes you may first try this solution by scanning the Enable Telepen barcode ...

Page 202: ...es with either the minimum or maximum length If minimum length is same as maximum length only Telepen barcodes with that length are to be decoded Set the scanner to decode Code 16K barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes se...

Page 203: ...ters which are calculated values used to verify the integrity of the data If the Disable option is enabled the scanner transmits Telepen barcodes as is TLPCHK0 Disable TLPCHK1 Enable But Do Not Transmit Check Character TLPCHK2 Enable And Transmit Check Character Output TLPASC0 Full ASCII Output TLPASC1 Numeric Only Output ...

Page 204: ...190 TLPASC2 Full ASCII and Numeric Only Output ...

Page 205: ...191 PDF417 Restore Factory Defaults PDFDEF Restore the Factory Defaults of PDF417 Enable Disable PDF417 PDFENA1 Enable PDF417 PDFENA0 Disable PDF417 I ...

Page 206: ... only want to read PDF417 barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode PDF417 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan th...

Page 207: ...r specifications and be placed closely together There are 3 options for reading PDF417 twin codes Single PDF417 Only Read either PDF417 code Twin PDF417 Only Read both PDF417 codes Both Single Twin Read both PDF417 codes If successful transmit as twin PDF417 only Otherwise try single PDF417 only PDFDOU0 Single PDF417 Only PDFDOU1 Twin PDF417 Only PDFDOU2 Both Single Twin ...

Page 208: ...k bars on a bright background Inverse barcode Bright bars on a dark background PDFINV0 Decode Regular PDF417 Barcodes Only PDFINV1 Decode Inverse PDF417 Barcodes Only PDFINV2 Decode Both Character Encoding PDFENC0 Default Character Encoding ...

Page 209: ...195 PDFENC1 UTF 8 ...

Page 210: ...196 PDF417 ECI Output PDFECI0 Disable PDF417 ECI Output PDFECI1 Enable PDF417 ECI Output ...

Page 211: ...re the Factory Defaults of Micro PDF417 Enable Disable Micro PDF417 MPDENA1 Enable Micro PDF417 MPDENA0 Disable Micro PDF417 If the scanner fails to identify Micro PDF417 barcodes you may first try this solution by scanning the Enable Micro PDF417 barcode ...

Page 212: ...only want to read Micro PDF417 barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Micro PDF417 barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendi...

Page 213: ... QRCDEF Restore the Factory Defaults of QR Code Enable Disable QR Code QRCENA1 Enable QR Code QRCENA0 Disable QR Code If the scanner fails to identify QR Code barcodes you may first try this solution by scanning the Enable QR Code barcode ...

Page 214: ... only want to read QR Code barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode QR Code barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan ...

Page 215: ... placed closely together There are 3 options for reading QR twin codes Single QR Only Read either QR code Twin QR Only Read both QR codes Transmission sequence left upper QR code followed by right lower QR code Both Single Twin Read both QR codes If successful transmit as twin QR only Otherwise try single QR only QRCDOU0 Single QR Only QRCDOU1 Twin QR Only QRCDOU2 Both Single Twin ...

Page 216: ...ark bars on a bright background Inverse barcode Bright bars on a dark background QRCINV0 Decode Regular QR Barcodes Only QRCINV1 Decode Inverse QR Barcodes Only QRCINV2 Decode Both Character Encoding QRCENC0 Default Character Encoding ...

Page 217: ...203 QRCENC1 UTF 8 ...

Page 218: ...204 QR ECI Output QRCECI0 Disable QR ECI Output QRCECI1 Enable QR ECI Output ...

Page 219: ... MQRDEF Restore the Factory Defaults of Micro QR Enable Disable Micro QR MQRENA1 Enable Micro QR MQRENA0 Disable Micro QR If the scanner fails to identify Micro QR barcodes you may first try this solution by scanning the Enable Micro QR barcode ...

Page 220: ...y want to read Micro QR barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Micro QR Code barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Sc...

Page 221: ...store the Factory Defaults of Aztec Code Enable Disable Aztec Code AZTENA1 Enable Aztec Code AZTENA0 Disable Aztec Code If the scanner fails to identify Aztec Code barcodes you may first try this solution by scanning the Enable Aztec Code barcode ...

Page 222: ...ou only want to read Aztec barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Aztec barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan th...

Page 223: ...209 Read Multi barcodes on an Image There are three options Mode 1 Read one barcode only Mode 2 Read fixed number of barcodes only AZTMOD1 Mode 1 AZTMOD2 Mode 2 ...

Page 224: ...210 Set the Number of Barcodes AZTMUL1 1 AZTMUL2 2 AZTMUL3 3 AZTMUL4 4 AZTMUL5 5 AZTMUL6 6 ...

Page 225: ...211 AZTMUL7 7 AZTMUL8 8 ...

Page 226: ...212 Character Encoding AZTENC0 Default Character Encoding AZTENC1 UTF 8 Aztec ECI Output AZTECI0 Disable Aztec ECI Output AZTECI1 Enable Aztec ECI Output ...

Page 227: ...store the Factory Defaults of Data Matrix Enable Disable Data Matrix DMCENA1 Enable Data Matrix DMCENA0 Disable Data Matrix If the scanner fails to identify Data Matrix barcodes you may first try this solution by scanning the Enable Data Matrix barcode ...

Page 228: ... only want to read Data Matrix barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Data Matrix barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix...

Page 229: ...ions for reading Data Matrix twin codes Single Data Matrix Only Read either Data Matrix code Twin Data Matrix Only Read both Data Matrix codes Transmission sequence left upper Data Matrix code followed by right lower Data Matrix code Both Single Twin Read both Data Matrix codes If successful transmit as twin Data Matrix only Otherwise try single Data Matrix only DMCDOU0 Single Data Matrix Only DMC...

Page 230: ...des having different amounts of models in length and width 6 16 6 14 14 22 DMCREC1 Enable Rectangular Barcode DMCREC0 Disable Rectangular Barcode Data Matrix Inverse Regular barcode Dark bars on a bright background Inverse barcode Bright bars on a dark background DMCINV0 Decode Regular Data Matrix Barcodes Only DMCINV1 Decode Inverse Data Matrix Barcodes Only ...

Page 231: ...217 DMCINV2 Decode Both ...

Page 232: ...218 Character Encoding DMCENC0 Default Character Encoding DMCENC1 UTF 8 Data Matrix ECI Output DMCECI0 Disable Data Matrix ECI Output DMCECI1 Enable Data Matrix ECI Output ...

Page 233: ...CDEF Restore the Factory Defaults of Maxicode Enable Disable Maxicode MXCENA1 Enable Maxicode MXCENA0 Disable Maxicode If the scanner fails to identify Maxicode barcodes you may first try this solution by scanning the Enable Maxicode barcode ...

Page 234: ...only want to read Maxicode barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Maxicode barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan...

Page 235: ...actory Defaults GMCDEF Restore the Factory Defaults of GM Enable Disable GM GMCENA1 Enable GM GMCENA0 Disable GM If the scanner fails to identify GM barcodes you may first try this solution by scanning the Enable GM barcode ...

Page 236: ... only want to read GM barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode GM barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan the Set th...

Page 237: ...EDEF Restore the Factory Defaults of Code One Enable Disable Code One ONEENA1 Enable Code One ONEENA0 Disable Code One If the scanner fails to identify Code One barcodes you may first try this solution by scanning the Enable Code One barcode ...

Page 238: ... only want to read Code One barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Code One barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Sca...

Page 239: ...s of Chinese Sensible Code Enable Disable Chinese Sensible Code CSCENA1 Enable Chinese Sensible Code CSCENA0 Disable Chinese Sensible Code If the scanner fails to identify Chinese Sensible Code barcodes you may first try this solution by scanning the Enable Chinese Sensible Code barcode ...

Page 240: ... only want to read Chinese Sensible Code barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Chinese Sensible Code barcodes containing between 8 and 12 characters 1 Scan the Set the Minimum Length barcode 2 Scan the numeric barcode 8 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes...

Page 241: ... codes Single Chinese Sensible Code Only Read either Chinese Sensible code Twin Chinese Sensible Code Only Read both Chinese Sensible codes Transmission sequence left upper Chinese Sensible code followed by right lower Chinese Sensible code Both Single Twin Read both Chinese Sensible codes If successful transmit as twin Chinese Sensible Code only Otherwise try single Chinese Sensible Code only CSC...

Page 242: ...erse Regular barcode Dark bars on a bright background Inverse barcode Bright bars on a dark background CSCINV0 Decode Regular Chinese Sensible Barcodes Only CSCINV1 Decode Inverse Chinese Sensible Barcodes Only CSCINV2 Decode Both ...

Page 243: ...e USPS Postnet PNTENA1 Enable USPS Postnet PNTENA0 Disable USPS Postnet If the scanner fails to identify USPS Postnet barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable USPS Postnet barcode Transmit Check Character PNTCHK1 Do Not Transmit USPS Postnet Check Character ...

Page 244: ...Defaults ILGDEF Restore the Factory Defaults of USPS Intelligent Mail Enable Disable USPS Intelligent Mail ILGENA1 Enable USPS Intelligent Mail ILGENA0 Disable USPS Intelligent Mail If the scanner fails to identify USPS Intelligent Mail barcodes you may first try this solution by scanning ...

Page 245: ...231 the Enable USPS Intelligent Mail barcode ...

Page 246: ...Restore the Factory Defaults of Royal Mail Enable Disable Royal Mail ROYENA1 Enable Royal Mail ROYENA0 Disable Royal Mail If the scanner fails to identify Royal Mail barcodes you may first try this solution by scanning the Enable Royal Mail barcode ...

Page 247: ...store the Factory Defaults of USPS Planet Enable Disable USPS Planet PLAENA1 Enable USPS Planet PLAENA0 Disable USPS Planet If the scanner fails to identify USPS Planet barcodes you may first try this solution by scanning the Enable USPS Planet barcode ...

Page 248: ...r PLACHK1 Do Not Transmit USPS Planet Check Character PLACHK2 Transmit USPS Planet Check Character KIX Post Restore Factory Defaults KIXDEF Restore the Factory Defaults of KIX Post Enable Disable KIX Post KIXENA1 Enable KIX Post ...

Page 249: ...235 KIXENA0 Disable KIX Post If the scanner fails to identify KIX Post barcodes you may first try this solution by scanning the Enable KIX Post barcode ...

Page 250: ...ry Defaults of Australian Postal Enable Disable Australian Postal APLENA1 Enable Australian Postal APLENA0 Disable Australian Postal If the scanner fails to identify Australian Postal barcodes you may first try this solution by scanning the Enable Australian Postal barcode ...

Page 251: ...e Factory Defaults of Specific OCR B Enable Disable Specific OCR B SOBENA1 Enable Specific OCR B SOBENA0 Disable Specific OCR B If the scanner fails to identify Specific OCR B barcodes you may first try this solution by scanning the Enable Specific OCR B barcode ...

Page 252: ...re the Factory Defaults of Passport OCR Enable Disable Passport OCR PASENA1 Enable Passport OCR PASENA0 Disable Passport OCR If the scanner fails to identify Passport OCR barcodes you may first try this solution by scanning the Enable Passport OCR barcode ...

Page 253: ... the Default Data Format code below DFMDEF Default Data Format Add a Data Format Data format is used to edit barcode data When you create a data format you must select one of the four labels Format_0 Format_1 Format_2 and Format_3 for your data format specify the application scope of data format such as barcode type and data length and include formatter commands Multiple data formats may be create...

Page 254: ...Appendix and find the ID number of the symbology to which you want to apply the data format Scan three numeric barcodes for the symbology ID number If you wish to create a data format for all symbologies scan 999 Step 8 Set barcode data length Specify what length of data will be acceptable for this symbology Scan the four numeric barcodes that represent the data length 9999 is a universal number i...

Page 255: ...the barcodes 0010 Only a length of 10 characters applicable 7 Scan the alphanumeric barcodes F141 Send all characters followed by A HEX 41 8 Scan the Save barcode Save the data format To streamline the programming process you may as well generate a batch barcode by inputting the command e g DFMADD069990020010F141 used to create a data format See the Use Batch Barcode section in Chapter 10 to learn...

Page 256: ...which you want to apply the data format 3 characters 999 indicates all symbologies Data length The length of data that will be acceptable for this symbology 4 characters 9999 indicates all lengths For example 32 characters should be entered as 0032 Formatter commands The command string used to edit data For more information see the Formatter Command Type 6 section in this chapter Suffix ETX HEX 3B...

Page 257: ...ied accordingly and gets outputted without prefixes and suffixes even if prefix and suffix are enabled Any data that does not match your data format requirements generates an error beep if Non Match Error Beep is turned ON and the data in that barcode is not transmitted Enable Data Formatter Not Required Keep Prefix Suffix Scanned data that meets your data format requirements is modified according...

Page 258: ...MENA3 Enable Data Formatter Not Required Keep Prefix Suffix DFMENA4 Enable Data Formatter Not Required Drop Prefix Suffix Non Match Error Beep If Non Match Error Beep is turned ON the scanner generates an error beep when a barcode is encountered that does not match your required data format DFMTON0 Non Match Error Beep Off ...

Page 259: ...245 DFMTON1 Non Match Error Beep On ...

Page 260: ...ta Format Selection After enabling the Data Formatter you can select a data format you want to use by scanning the appropriate barcode below DFMUSE0 Format_0 DFMUSE1 Format_1 DFMUSE2 Format_2 DFMUSE3 Format_3 ...

Page 261: ...scanner to the data format you saved as Format_3 You can switch to Format_1 for a single trigger pull by scanning the Single Scan Format_1 barcode below The next barcode that is scanned uses Format_1 then reverts back to Format_3 Note This setting will be lostby removing power from the scanner or turning off rebooting the device DFMSIN0 Single Scan Format_0 DFMSIN1 Single Scan Format_1 DFMSIN2 Sin...

Page 262: ...e barcode Delete all data formats Scan the Clear All barcode DFMCAL Clear All DFMCLR Clear One Query Data Formats You may scan the appropriate barcode below to get the information of data format s created by you or preset by manufacturer For instance if you have added Format_0 as per the example in the Add a Data Format section in this chapter scanning the Query Current Data Formats barcode you wi...

Page 263: ...249 DFMQFA Query Preset Data Formats ...

Page 264: ...ting from current cursor position followed by an insert character F2 Send a number of characters Syntax F2nnxx nn The numeric value 00 99 for the number of characters xx The insert character s hex value Include in the output message a number of characters followed by an insert character Start from the current cursor position and continue for nn characters or through the last character in the input...

Page 265: ...mand string F3440D F3 is the Send all characters up to a particular character command 44 is the hex value for a D 0D is the hex value for a CR The data is output as 1234567890ABC CR E9 Send all but the last characters Syntax E9nn nn The numeric value 00 99 for the number of characters that will not be sent at the end of the message Include in the output message all but the last nn characters start...

Page 266: ...re F4 is the Insert a character multiple times command 09 is the hex value for a horizontal tab 02 is the number of time the tab character is sent The data is output as 1234567890AB tab tab B3 Insert symbology name Insert the name of the barcode s symbology in the output message without moving the cursor B4 Insert barcode length Insert the barcode s length in the output message without moving the ...

Page 267: ...e number of time the space character is sent B4 is the Insert barcode length command F4 is the Insert a character multiple times command 20 is the hex value for a space 01 is the number of time the space character is sent F1 is the Send all characters command 0D is the hex value for a CR The data is output as Code128 20 1234567890ABCDEFGHIJ CR Move Commands F5 Move the cursor forward a number of c...

Page 268: ...is the Send all characters command 0D is the hex value for a CR The data is output as 4567890ABCDEFGHIJ CR F6 Move the cursor backward a number of characters Syntax F6nn nn The numeric value 00 99 for the number of characters the cursor should be moved back Move the cursor back nn characters from current cursor position F7 Move the cursor to the beginning Syntax F7 Move the cursor to the first cha...

Page 269: ... the letter D in barcodes and send all the data that follows including the D Using the barcode above Command string F844F10D F8 is the Search forward for a character command 44 is the hex value for D F1 is the Send all characters command 0D is the hex value for a CR The data is output as DEFGHIJ CR F9 Search backward for a character Syntax F9xx xx The search character s hex value Search the input ...

Page 270: ...follows including FGH Using the barcode above Command string B00003464748F10D B0 is the Search forward for a string command 0003 is the string length 3 characters 46 is the hex value for F 47 is the hex value for G 48 is the hex value for H F1 is the Send all characters command 0D is the hex value for a CR The data is output as FGHIJ CR B1 Search backward for a string Syntax B1nnnnS nnnn The strin...

Page 271: ... that follows E6 searches forward for the first character that is not zero then sends all the data after followed by a carriage return Using the barcode above Command string E630F10D E6 is the Search forward for a non matching character command 30 is the hex value for 0 F1 is the Send all characters command 0D is the hex value for a CR The data is output as 123abc CR E7 Search backward for a non m...

Page 272: ... to remove the spaces before sending the data Using the barcode above Command string FB0120F10D FB is the Suppress characters command 01 is the number of the characters to be suppressed 20 is the hex value for a space F1 is the Send all characters command 0D is the hex value for a CR The data is output as 1234_5 678 CR E4 Replace characters Syntax E4nnxx1xx2yy1yy2 zz1zz2 nn The total count of the ...

Page 273: ... the zeros in the barcode above with carriage returns Command string E402300DF10D E4 is the Replace characters command 02 is the total count of characters to be replaced plus the replacement characters 0 is replaced by CR so total characters 2 30 is the hex value for 0 0D is the hex value for a CR the character that will replace the 0 F1 is the Send all characters command 0D is the hex value for a...

Page 274: ...string with SS2 string of length NN2 in the output message until every SS1 stringis replaced or the count of replacements made reaches nn times without moving the cursor BA Example Replace 23 s with ABC s in barcode data If the barcode has a string of characters that the host application does not want included you can use the BA command to replace the string with something else In this example you...

Page 275: ...moved you can use the BA command to replace the string with NUL In this example you will remove the first occurrence of 23 in the barcode above Command string BA0102323300F100 BA is the Replace a string with another command 01 is the count of replacements to be made 02 is the length of the string to be replaced 32 is the hex value for 2 character in the string to be replaced 33 is the hex value fo...

Page 276: ...he 5th and 6th character Send the first 5 characters in a barcode wait for 1s then send the rest of the barcode data Command string F20500EF0200E900 F2 is the Send a number of characters command 05 is the number of characters to send 00 is the hex value for a Null character EF is the Insert a delay command 0200 is the delay value 5msX200 1000ms 1s E9 is the Send all but the last characters command...

Page 277: ...not and should not have all information we need such as barcode type data acquisition time and delimiter in order to keep the barcodes short and flexible Preffix and suffix are how to fulfill the needs mentioned above They can be added removed and modified while the original barcode data remains intact Barcode processing procedure 1 Edit data with Data Formatter 2 Append prefix suffix 3 Pack data ...

Page 278: ...x suffix Enable All Prefixes Suffixes Allow to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission APSENA0 Disable All Prefixes Suffixes APSENA1 Enable All Prefixes Suffixes Prefix Sequence PRESEQ0 Code ID Custom AIM ID PRESEQ1 Custom Code ID AIM ID ...

Page 279: ...ix To set a custom prefix scan the Set Custom Prefix barcode then the numeric barcodes corresponding to the hexadecimal value of a desired prefix then the Save barcode Note A custom prefix cannot exceed 10 characters CPRSET Set Custom Prefix Set the custom prefix to CODE HEX 0x43 0x4F 0x44 0x45 1 Scan the Set Custom Prefix barcode 2 Scan the numeric barcodes 4 3 4 F 4 4 4 and 5 from the Digit Barc...

Page 280: ...ology identifier For the details see the AIM ID Table section in Appendix If AIM ID prefix is enabled the scanner will add the symbology identifier before the scanned data after decoding AIDENA0 Disable AIM ID Prefix AIDENA1 Enable AIM ID Prefix AIM ID is not user programmable ...

Page 281: ...wo English letters CIDENA0 Disable Code ID Prefix CIDENA1 Enable Code ID Prefix Restore All Default Code IDs For the information of default Code IDs see the Code ID Table section in Appendix CIDDEF Restore All Default Code IDs Modify Code ID See the examples below to learn how to modify a Code ID and restore the default Code IDs of all symbologies ...

Page 282: ...7 Code ID barcode 2 Scan the numeric barcodes 7 and 0 from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix Restore the default Code IDs of all symbologies 1 Scan the Restore All Default Code IDs barcode ...

Page 283: ...269 1D symbologies CID002 Modify Code 128 Code ID CID003 Modify GS1 128 Code ID CID004 Modify EAN 8 Code ID CID005 Modify EAN 13 Code ID CID006 Modify UPC E Code ID CID007 Modify UPC A Code ID ...

Page 284: ...270 CID008 Modify Interleaved 2 of 5 Code ID CID009 Modify ITF 14 Code ID CID010 Modify ITF 6 Code ID CID011 Modify Matrix 2 of 5 Code ID CID013 Modify Code 39 Code ID CID015 Modify Codabar Code ID ...

Page 285: ...271 CID017 Modify Code 93 Code ID CID019 Modify China Post 25 Code ID CID023 Modify ISSN Code ID ...

Page 286: ...272 CID024 Modify ISBN Code ID CID025 Modify Industrial 25 Code ID CID026 Modify Standard 25 Code ID CID027 Modify Plessey Code ID CID028 Modify Code 11 Code ID CID029 Modify MSI Plessy Code ID ...

Page 287: ...273 CID030 Modify GS1 Composite Code ID CID031 Modify GS1 Databar Code ID ...

Page 288: ...74 2D symbologies CID032 Modify PDF417 Code ID CID033 Modify QR Code ID CID034 Modify Aztec Code ID CID035 Modify Data Matrix Code ID CID036 Modify Maxicode Code ID CID039 Modify Chinese Sensible Code ID ...

Page 289: ...275 CID042 Modify Micro PDF417 Code ID CID043 Modify Micro QR Code ID ...

Page 290: ...gies CID096 Modify USPS Postnet Code ID CID097 Modify USPS Inteligent Mail Code ID CID098 Modify Royal Mail Code ID CID099 Modify USPS Planet Code ID CID100 Modify KIX Post Code ID CID101 Modify Australian Postal Code ID ...

Page 291: ...ffix Set Custom Suffix To set a custom suffix scan the Set Custom Suffix barcode then the numeric barcodes corresponding to the hexadecimal value of a desired suffix then the Save barcode Note A custom suffix cannot exceed 10 characters CSUSET Set Custom Suffix Set the custom suffix to CODE HEX 0x43 0x4F 0x44 0x45 1 Scan the Set Custom Suffix barcode 2 Scan the numeric barcodes 4 3 4 F 4 4 4 and 5...

Page 292: ...er it TSUENA0 Disable Terminating Character Suffix TSUENA1 Enable Terminating Character Suffix Set Terminating Character Suffix To set a terminating character suffix scan the Set Terminating Character Suffix barcode then the numeric barcodes corresponding to the hexadecimal value of a desired terminating character then the Save barcode Note A terminating character suffix cannot exceed 2 characters...

Page 293: ...aracter suffix to 0x0A 1 Scan the Set Terminating Character Suffix barcode 2 Scan the numeric barcodes 0 and A from the Digit Barcodes section in Appendix 3 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 4 Scan the Enable Terminating Character Suffix barcode ...

Page 294: ...n Note that there is no space between a command and its terminator semicolon 3 Use the barcode generator software to generate a 2D batch barcode Example Create a batch barcode for Illumination On Sense Mode Decode Session Timeout 2s 1 Input the commands ILLSCN1 SCNMOD2 ORTSET2000 2 Generate a batch barcode When setting up a scanner with the above configuration scan the Enable Batch Barcode barcode...

Page 295: ...ation refer to the Use of Programming Command section in Chapter 3 Create a Batch Barcode Batch barcodes can be produced in the format of PDF417 QR Code or Data Matrix Example Create a batch barcode for lllumination On Sense Mode Decode Session Timeout 2s 1 Input the following commands ILLSCN1 SCNMOD2 ORTSET2000 2 Generate a PDF417 batch barcode ...

Page 296: ...282 Use Batch Barcode To put a batch barcode into use scan the following barcodes Use the example above BATCHS Enable Batch Barcode Batch Barcode ...

Page 297: ...283 Appendix Digit Barcodes 0 9 DIGIT0 0 DIGIT1 1 DIGIT2 2 DIGIT3 3 DIGIT4 4 ...

Page 298: ...284 DIGIT5 5 DIGIT6 6 DIGIT7 7 DIGIT8 8 DIGIT9 9 ...

Page 299: ...285 A F DIGITA A DIGITB B DIGITC C DIGITD D DIGITE E DIGITF F ...

Page 300: ...d then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you scan Delete the Last Digit The last digit 3 will be removed Delete All Digits All digits 123 will be removed Cancel The maximum length configuration will be cancelled And the scanner is still in the setup mode DIGSAV Sa...

Page 301: ...ood Read Beeps 1 Good Read Beep Interval Time Short Good Read Vibration Off Good Read Vibration Duration 300ms Default Scan Mode Pre aiming Mode Decode Session Timeout 3 000ms 1 3 600 000ms 0 infinite Timeout between Decodes 500ms 1 10 000ms Reread Timeout Enabled 15 000ms 1 3 600 000ms Good Read Delay Disabled 500ms 1 3 600 000ms Image Decoding Timeout 350ms 1 3 000ms Sensitivity Level 1 Level 1 ...

Page 302: ... HID Keyboard Emulate Numeric Keypad 1 Disabled USB HID Keyboard Emulate Numeric Keypad 2 Disabled USB HID Keyboard Polling Rate 4ms USB HID Keyboard Symbologies Global Settings 1D Twin Code Single 1D Code Only Enhance Poor Quality 1D Barcode Decoding Off Code 128 Code 128 Enabled Maximum Length 48 Minimum Length 1 EAN 8 EAN 8 Enabled Check Character Transmit 2 Digit Add On Code Disabled 5 Digit A...

Page 303: ...Do Not Require Add On Code EAN 13 Beginning with 979 Add On Code Required Do Not Require Add On Code UPC E UPC E0 Enabled UPC E1 Disabled Check Character Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not required Add On Code Separator Off Transmit Preamble Character System Character Convert UPC E to UPC A Disabled UPC A UPC A Enabled Check Character Transmit 2 Digi...

Page 304: ...Disabled Code 32 Start Stop Character Do not transmit Code 32 Check Character Do not transmit Maximum Length 48 Minimum Length 1 Codabar Codabar Enabled Check Character Verification Disabled Start Stop Character Do not transmit ABCD ABCD as Start Stop Character Maximum Length 60 Minimum Length 2 Code 93 Code 93 Disabled Check Character Do not transmit Check Character Verification Enabled Maximum L...

Page 305: ... GS1 Composite EAN UCC Composite GS1 Composite Disabled UPC EAN Composite Disabled Code 11 Code 11 Disabled Check Character Transmit Check Character Verification One Check Character MOD11 Maximum Length 48 Minimum Length 4 ISBN ISBN Disabled ISBN Format ISBN 10 ISSN ISSN Disabled Industrial 25 Industrial 25 Disabled Check Character Verification Disabled Maximum Length 48 Minimum Length 6 Standard ...

Page 306: ...m Length 48 Minimum Length 4 MSI Plessey MSI Plessey Disabled Check Character Transmit Check Character Verification One Check Character MOD10 Maximum Length 48 Minimum Length 4 Code 49 Code 49 Disabled Maximum Length 80 Minimum Length 1 Code 16K Code 16K Disabled Maximum Length 80 Minimum Length 1 Telepen Telepen Disabled Maximum Length 80 Minimum Length 1 Check Character Verification Full ASCII O...

Page 307: ... QR ECI Output Enabled Maximum Length 7089 Minimum Length 1 Micro QR Micro QR Enabled Maximum Length 35 Minimum Length 1 Aztec Aztec Disabled Read Multi barcodes on an Image Mode 1 Number of Barcodes on an Image 1 Character Encoding Default Character Encoding Aztec ECI Output Enabled Maximum Length 3832 Minimum Length 1 Data Matrix Data Matrix Enabled Read Single DM Only Enabled Rectangular Barcod...

Page 308: ...ngth 1 GM Code GM Disabled Maximum Length 2751 Minimum Length 1 Code One Code One Disabled Maximum Length 3550 Minimum Length 1 USPS Postnet USPS Postnet Disabled Check Character Transmit USPS Intelligent Mail USPS Intelligent Mail Disabled Royal Mail Royal Mail Disabled USPS Planet USPS Planet Disabled Check Character Transmit KIX Post KIX Post Disabled Australian Postal Australian Postal Disable...

Page 309: ...efix Suffix Prefix Sequence Code ID Custom AIM ID Custom Prefix Disabled Max 10 characters AIM ID Prefix Disabled Code ID Prefix Disabled One or two English letters Custom Suffix Disabled Max 10 characters Data Packing Disable Data Packing Terminating Character Suffix Enabled CR 0x0D Max 2 characters ...

Page 310: ...n E3 UPC A E0 UPC A with Addon E3 Interleaved 2 of 5 Febraban Im 0 1 3 ITF 14 Im 1 3 ITF 6 Im 1 3 Matrix 2 of 5 X0 Code 39 Code 32 Am 0 1 3 4 5 7 Codabar Fm 0 2 4 Code 93 G0 China Post 25 X0 ISSN X0 ISBN X0 Industrial 25 S0 Standard 25 R0 COOP 25 X0 AIM 128 C2 ISBT 128 C4 Plessey P0 Code 11 Hm 0 1 3 MSI Plessey Mm 0 1 GS1 Composite em 0 3 GS1 Databar RSS e0 Code 49 T0 Code 16K K0 ...

Page 311: ...Q1 Code One X0 USPS Postnet X0 USPS Inteligent Mail X0 Royal Mail X0 USPS Planet X0 KIX Post X0 Australian Postal X0 Specific OCR B o2 Passport OCR o2 Note m represents the AIM modifier character Refer to ISO IEC 15424 2008 Information technology Automatic identification and data capture techniques Data Carrier Identifiers including Symbology Identifiers for AIM modifier character details ...

Page 312: ...2 of 5 Febraban e ITF 14 e ITF 6 e Matrix 2 of 5 v Code 39 Code 32 b Codabar a Code 93 i China Post 25 X ISSN g ISBN B Industrial 25 I Standard 25 f COOP 25 X AIM 128 X ISBT 128 X Telepen X Deutsche 14 X Deutsche 12 X Plessey n Code 11 H MSI Plessey m GS1 Composite y GS1 Databar RSS R Code 49 X Code 16K X PDF417 r ...

Page 313: ...Data Matrix u MaxiCode x Chinese Sensible Code h GM Code x Micro PDF417 R Micro QR X Code One X USPS Postnet P USPS Inteligent Mail M Royal Mail x USPS Planet L KIX Post K Australian Postal A Specific OCR B S Passport OCR O ...

Page 314: ...300 ...

Page 315: ...4 009 ITF 6 010 Matrix 2 of 5 011 Code 39 Code 32 013 Codabar 015 Code 93 017 China Post 25 019 AIM 128 020 ISBT 128 021 COOP 25 022 ISSN 023 ISBN 024 Industrial 25 025 Standard 25 026 Plessey 027 Code11 028 MSI Plessey 029 GS1 Composite 030 GS1 Databar RSS 031 PDF417 032 QR Code 033 Aztec 034 Data Matrix 035 Maxicode 036 Chinese Sensible Code 039 GM Code 040 ...

Page 316: ...2 Micro QR 043 Code One 048 Specific OCR B 064 Passport OCR 066 USPS Postnet 096 USPS Inteligent Mail 097 Royal Mail 098 USPS Planet 099 KIX Post 100 Australian Postal 101 Deutsche 14 128 Deutsche 12 129 Telepen 130 Code 49 132 Code 16K 133 ...

Page 317: ...0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgment 16 22 SYN Synchronous Idle 17 23 ETB End of Trans Block 18 24 CAN Cancel 19 25 EM End of Medium 1a 26 SUB Substitute 1b...

Page 318: ...ollar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Left Opening Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign ...

Page 319: ...65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket ...

Page 320: ...00 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete ...

Page 321: ...307 ...

Page 322: ...remont Blvd Fremont CA 94538 USA Tel 510 490 3888 Fax 510 490 3887 Email info newlandna com Web www newlandamerica com Newland Latin America Tel 1 239 598 0068 Fax 1 239 280 1238 Email info newlandla com Web www newlandamerica com Newland Taiwan Inc 7F 6 No 268 Liancheng Rd Jhonghe Dist 235 New Taipei City Taiwan Tel 886 2 7731 5388 Fax 886 2 7731 5389 Email info newland id com tw Web www newland ...