80
Symbology
AIM ID
Remark
Code 39
]A0
Transmit barcodes as is; Full ASCII disabled; no check digit
verification
]A1
One check digit, MOD 43; transmit check digit
]A3
One check digit, MOD 43; do not transmit check digit
]A4
Full ASCII enabled; no check digit verification
]A5
Full ASCII enabled; MOD43; transmit check digit
]A7
Full ASCII enabled; MOD43; do not transmit check digit
Codabar
]F0
Standard Codabar
]F1
ABC Codabar
]F2
Transmit check digit after verification
]F4
Do not transmit check digit after verification
Code 93
]G0
Not specified
Code 11
]H0
One check digit, MOD11; transmit check digit
]H1
Two check digits, MOD11/MOD11; transmit check digit
]H3
Do not transmit check digit after verification
]H8
Two check digits, MOD11/MOD9; transmit check digit
]H9
No check digit verification
Plessey
]P0
Not specified
MSI-Plessey
]M0
One check digit, MOD10; transmit check digit
]M1
One check digit, MOD10; do not transmit check digit
]M7
Two check digits, MOD10 /MOD11; do not transmit check digit
]M8
Two check digits, MOD10 /MOD11; transmit check digit
]M9
No check digit verification
RSS-14
RSS-Limited
RSS-Expand
]e0
Standard
]e1
User-defined
]e2
User-defined
]e3
User-defined
PDF417
]L0
Comply with 1994 PDF417 specifications
Data Matrix
]d0
ECC 000 - 140
]d1
ECC 200
]d2
ECC 200; FNC1 is the 1st or 5th character after the start character