nlscan.com
Page 70
Symbols
Tools
Code Programming ON
Code Programming OFF
Select Message Length
It is used to program the valid reading length of Interleaved 2 of 5. The
scanner will send an error beep, if the decoded data length does not match the
valid length.
Interleaved 2 of 5 Message Length is de
fi
ned by
“
Min. Message Length
”
and
“
Max. Message Length
”
Interleaved 2 of 5
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is less
than Min Message Length, it means the scanner will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the scanner will only sup-
port barcodes of the length.
To set Min Message Length of Interleaved 2 of 5 as 8 bytes, and Max Message length as 12
bytes, read these programming codes:
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code Appendix (Pxxx)
4.
“
Save Programming
”
, see Digit Code Appendix (Pxxx)
5.
“
Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“
Code Programming OFF
”
Min Message Length
【
Pro CMD
:
99911206
】
Max Message Length
【
Pro CMD
:
99911207
】