4. CONSTRUCTION
3 4 5 1 2
8
7 6
9 10
1- Body
2- Lens Focusing Ring
3- Eyepiece
4- Switch Button for the Scope
5- IR Illuminator Switch
6- IR
Illuminator
7- Battery House Cover
8- Lens
Cover
9- Carrying Strap
10- Low battery indicator
8
5. OPERATION INSTRUCTIONS
WARNING!
NEVER OPERATE YOUR NIGHT VISION DEVICE IN
DAYLIGHT AREAS WITHOUT THE LENS COVER ON!
NEVER DIRECT THE LENS IN THE DIRECTION OF
BRIGHT LIGHT!
5.1 Pre-starting procedures.
1. Unpack the device. In
order to replace the battery unscrew
battery house cover (7) and replace the battery observing the polarity
indicated; close cover (7). First, make sure the lens cap (8) is closed:
Check the functioning of the device by switching it on (click switch
4) and looking through eye-piece (3). If power supply and the battery
is O.K., you will see greenish-lit screen. If the screen is not lit, check
the battery. Replace the battery if necessary. If everything works,
now is a great time to fill the warranty card. You can find the unit’s
serial number on the button.
5.2. Testing of operation
Turn on the device-using switch (4). Lens cap (8) must be on. Direct
the device on an object placed within 40-50 m from the viewer.
Turning the eye-piece (3) try to achieve the sharpest image on the
screen of the image tube. For close focusing rotate the front lens (2)
5.3.Operation at night
AT MOON LIGHT:
Unscrew the lens cover (8). Turn on the
device-using switch (4). Turning the eyepiece focusing lever (3)
adjust to achieve the most clear image on the screen. Then
obtain the
most
clear-cut image of the object focusing with ring,(2)
.
Repeat the
steps of focusing if necessary.
Note: The ON button is equipped with automatic shut off circuitry.
After a while, it will shut itself off, to prevent battery drain.
9