IMPORTANT INFORMATION 

Read prior to activation. 

You have purchased a sophisticated electronic device.  
To operate it properly, please read this manual 
carefully. 

Ignoring the operation procedures described in this 

manual will void your warranty. 

 

 

NEVER 

disassemble the unit. This device contains a 

source of high voltage, which may be hazardous to 
your health. 

 

NEVER 

open the objective lens of an active unit in 

bright light, including daylight. In the daytime the 
objective lens must be covered by cap. A tiny hole in 
the cap provides enough light for daytime testing. 

 

NEVER 

aim an active unit at intense light sources, 

such as lights, headlamps, campfires, the Moon, etc. 

 

NEVER 

reverse the polarity of a battery. 

 

NEVER 

connect the unit to any external power 

supplies.

 

 

ALWAYS 

remove battery when not in use for a long 

period. 

 

ALWAYS 

keep the objective lenses covered when not 

in use

 

ALWAYS 

store the device in a warm dry place.

 

Summary of Contents for NV66-G2

Page 1: ...Operation Manual NIGHT VISION BINOCULARS GOGGLES NV66 G2 105 Sparks Ave Toronto ON M2H 2S5 Canada...

Page 2: ......

Page 3: ...NEVER open the objective lens of an active unit in bright light including daylight In the daytime the objective lens must be covered by cap A tiny hole in the cap provides enough light for daytime tes...

Page 4: ...sional lens cleaning supplies Use only a soft clean cloth to clean the exterior of the device Keep the device away from sources of heat such as heating appliances sunlight or central heating Switch of...

Page 5: ...ast characteristic 8 3 4 Field of view cleanness 8 4 UNIT DESIGN 9 5 OPERATION INSTRUCTIONS 10 5 1 Installing battery 10 5 2 Switching the unit on 10 5 3 Switching the unit off 11 5 4 Operating at nig...

Page 6: ...green light through eyepieces 18 6 2 Image is unclear 18 6 3 Image flashes 18 6 4 Condensation accumulates on the parts 18 6 5 Visibility decreased or disappeared 19 7 WARRANTY 20 8 CUSTOMER SUPPORT 2...

Page 7: ...with a generation 2 intensifier tube which amplifies low light such as moonlight starlight or man made light Add on lens can be attached to the unit to increase magnification Unit can be mounted on a...

Page 8: ...Flip flop mechanism provides for unobstructed vision when the unit is mounted on headgear or helmet Waterproof design 1 meter deep immersion for 30 minutes Soft rubber eyecup makes viewing comfortabl...

Page 9: ...G2 unit with 1x lens and headgear 1 Lens cap 1 Neck strap 1 Soft case 1 Manual 1 Warranty card 1 AA battery 2 2 2 Optional accessories 3x 4x 5x 8x lenses Hard case Lens cleaning kit Helmet mount Exac...

Page 10: ...130 F2 3 216 4 F2 0 Interpupillary distance 57 73 mm Focus range 1x 0 25 m Dioptric correction 5 Battery type 2 standard AA batteries Battery life Over 80 hours without IR over 30 hours with IR Low ba...

Page 11: ...diameter 18 mm Photocathode type S 25 Photocathode sensitivity Integral 450 A lm Spectral at 850 nm 26 mA W Light amplification 20 000 fl fc Image magnification 1x Signal to noise ratio min 18 Curren...

Page 12: ...es mm Contrast transfer coefficient 2 5 0 83 7 5 0 56 15 0 0 30 3 4 Field of view cleanness Allowed spot diameter m I ZONE 0 5 6 mm II ZONE 5 6 14 7 mm III ZONE 14 7 17 5 mm Over 250 0 0 0 150 to 250...

Page 13: ...Off IR switch 6 Objective lens cover 2 Mounting socket 7 Objective lens 3 Eyepiece adjustment ring 8 Tightening screw 4 Eyepieces 9 Lever 5 Battery compartment cover 9 8 Fig 2 Headgear 1 2 7 6 5 3 4 F...

Page 14: ...compartment cover 5 Fig 1 and install 2 fresh AA batteries Observe the correct polarity indicated on the housing Screw in the battery compartment cover back 5 2 Switching the unit on In daylight put...

Page 15: ...red dot indicates that the IR illuminator is on In the daytime with lens cap on it is normal to observe a fuzzy image Switching on the unit device in the daytime is intended for testing purposes only...

Page 16: ...ble to anybody with a night vision device You can raise the unit up for unobstructed vision without taking the headgear off by using the flip flop feature Fig 2 To do so press the lever 9 and raise th...

Page 17: ...headgear adjust all the straps to the head size When wearing the unit the eye relief the distance between your eyes and the eyepieces should be 15 22 mm In order to achieve this loosen the locking sc...

Page 18: ...ockwise Once the lens has been removed store it in a safe clean space 4 Screw in clockwise new lens The threads are very fine to prevent humidity penetration and can be damaged easily Do not apply for...

Page 19: ...15 Fig 4 NV66 G2 with 4x lens Fig 5 NV66 G2 with 8x lens...

Page 20: ...an optional helmet mount This mount can be customized to fit a variety of existing helmet models The mount is attached to a helmet with straps 1 Locking screw 3 Flip Flop adjusting screws 2 Flip Flop...

Page 21: ...izontal and 15 20 degrees above horizontal Although the relative angles between these positions cannot be changed the starting point can be adjusted by screws 3 Fig 7 If you loosen them you can rotate...

Page 22: ...the image is still unfocused adjust the eyepieces see chapter 5 for details 6 3 Image flashes Image may flash during the first two minutes after activation It may continue flashing if exposed to brigh...

Page 23: ...s or headlights may cause visibility to degrade or even completely disappear Move the device away from the light source immediately The image will be restored within two minutes Adverse atmospheric co...

Page 24: ...e model the product or part thereof which on inspection by Newcon is found to be defective in materials or workmanship What This Warranty Does Not Cover NEWCON is not responsible for warranty service...

Page 25: ...ern Standard Time Under no circumstances should the equipment be sent to Newcon without authorisation from our technical support department Newcon accepts no responsibility for unauthorized returns To...

Page 26: ..._______________________________ Minimum Measured Resolution lp mm 45 Photocathode sensitivity integral A lm 450 Light amplification 20000 Date of production ___________________________________________...

Page 27: ...________________________ The unit complies with all technical specifications and has passed the inspection Date of production ______________________________________________ Quality Inspector s signatu...

Page 28: ...NEWCON OPTIK Printed in Canada R1 5 11...

Reviews: