background image

P/N 111525 Rev 

081003

 

 

N E W C O    E N T E R P R I S E S 

INSTALLATION and OPERATION MANUAL for VIP 

II

 BREWERS 

 

 

BREWER SPECIFICATIONS 

 

Model 

 

Width 

 

Length 

 

Height 

US 

120V Amps 

CANADA 

 120V Amps 

 

 

 

 

 

 

VIP-LD 8-5/8” 16-5/8” 17-1/2” 

13 

11.7 

VIP-TD 8-5/8” 16-5/8” 23-3/4” 

13 

11.7 

 
NOTE: Automatic models without faucet is also available. 

Model VIP-LD 

Summary of Contents for VIP-LD

Page 1: ...LATION and OPERATION MANUAL for VIP II BREWERS BREWER SPECIFICATIONS Model Width Length Height US 120V Amps CANADA 120V Amps VIP LD 8 5 8 16 5 8 17 1 2 13 11 7 VIP TD 8 5 8 16 5 8 23 3 4 13 11 7 NOTE Automatic models without faucet is also available Model VIP LD ...

Page 2: ...rew cycle will begin Otherwise the brewer will go into the autoarm mode In the autoarm mode the heating light will be lit and the corresponding switch light will begin to flash indicating that the unit is in the brew mode but is not up to temperature When the tank reaches the preset temperature the brew cycle will begin Note To accelerate the set up time the Tank Temp adjustment dial may be rotate...

Page 3: ... and hold the appropriate brew switch for 3 seconds until brewing begins Do not remove dispenser Brew cycle may be canceled by depressing the cancel switch The heating and brew switch light should no longer be flashing 7 Hot water will be delivered through the sprayhead This distributes the hot water evenly over the coffee bed within the brew basket The coffee brew will drain from the brew basket ...

Page 4: ... are positioned above the fill valve Refer to wiring diagram on page 6 The autoarm feature may be bypassed for individual brew cycles by holding in the brew start switch for about 3 seconds Release switch when brew cycle starts Visa Brew Continues to flash the brewing light after the fill portion of the brew cycle has stopped alerting the user that the brewed hot coffee has not finished draining f...

Page 5: ... Disable Auto Arm Autobrew Heating half brew lights on steady Temperature Probe Thermistor is open Replace Thermistor Autobrew Heating full brew lights on steady Temperature Probe Thermistor shorted Replace Thermistor IN CASES WHERE THERE IS A HEATER OR FILL PROBE ERROR THE BREWER CAN BE RESET BY HOLDING DOWN THE CANCEL BUTTON FOR APPROXIMATELY 5 SECONDS ERROR WILL CLEAR REPLACEMENT PARTS LIST Par...

Page 6: ...material or workmanship and returned to our factory shipping cost prepaid No warranty expressed or implied other than the aforesaid is made or authorized by Newco Enterprises Inc Prompt disposition will be made if item proves to be defective within warranty Before returning any item write or call Newco or the dealer from whom the product was purchased giving model number serial number and date of ...