Plumber’s Installation Instructions
CAUTION: Disconnect
Power to machine before proceeding with plumbing installation
.
1)
Attach water line to water filter, rear of machine.
2)
Flush water line before installing machine. Machine should be connected to COLD WATER LINE ONLY.
3)
Water pressure should be at least 40 lbs. For less than a 25 ft run, use 1/4" copper tubing and connect to
1/2" or larger water line. For longer runs, use 3/8" copper tubing & connect to 1/2" or larger water line and
provide an adapter fitting for connection to the brewer.
A dedicated water line is necessary for this
machine. Minimum flow rate is 1GPM.
4)
If installed with saddle valve, the valve should have a minimum of 1/8" porthole for up to 25 ft run, and
5/16" porthole for over 25 ft runs.
5)
Manufacturer recommends connecting to copper tubing.
Electrical Hook-Up
WARNING
The Machine must be disconnected from the power source until specified in Installation
Instructions.
Determine the available on-site electrical requirements
Refer to Data Plate on the Machine, and local/national electrical codes to determine circuit
requirements.
CAUTION – Improper electrical installation will damage electronic components
.
Installation Instructions
WARNING: - Read and follow installation instructions before plugging or wiring in machine to electrical
circuit. Warranty will be void if machine is connected to any voltage other than that specified on the
nameplate serial tag.
1)
Machine must be on a flat and level surface. Plug or wire in machine to appropriate voltage as noted
on the machine serial tag. Serial tag is located on inside of machine.
2)
With water line connected, turn machine power ON (power switch located lower left rear of
machine). Install Drip tray and drip tray grate under brew area (slide tray between guide rails until
seated).
3)
Tank will automatically fill, and machine will start heating. If tank does not fill in 8 minutes, a tank
fill error will occur. (Note: To reset error power machine on/off with power switch).
4)
Allow 5 to 10 minutes for water in tank to heat to brewing temperature. (Additional water may drip
into drip tray on initial expansion of water in the tank). This will not occur thereafter.
5)
Heater will turn on when tank is at probe level. When tank noise is no longer heard, machine is
ready to operate
6)
In higher altitude locations (5000 feet above sea level) the thermostat may have to be
adjusted lower to prevent boiling: