Newco NHW-5 Operating Instructions Manual Download Page 6

 

 

PN 121586  8-29-2013 

 

 

 

 

Plumber’s Installation Instructions 

 

CAUTION: Disconnect

 

Power to machine before proceeding with plumbing installation

 

1) 

Attach water line to water filter, rear of machine. 

2) 

Flush water line before installing machine. Machine should be connected to COLD WATER LINE ONLY. 

3) 

Water pressure should be at least 40 lbs. For less than a 25 ft run, use 1/4" copper tubing and connect to 

1/2" or larger water line. For longer runs, use 3/8" copper tubing & connect to 1/2" or larger water line and 

provide an adapter fitting for connection to the brewer. 

 A dedicated water line is necessary for this 

machine. Minimum flow rate is 1GPM. 

4) 

If installed with saddle valve, the valve should have a minimum of 1/8" porthole for up to 25 ft run, and 

5/16" porthole for over 25 ft runs. 

5) 

Manufacturer recommends connecting to copper tubing. 

 
 

Electrical Hook-Up  

 

WARNING

  

The Machine must be disconnected from the power source until specified in Installation 
Instructions. 
Determine the available on-site electrical requirements 

Refer to Data Plate on the Machine, and local/national electrical codes to determine circuit 

requirements. 

CAUTION – Improper electrical installation will damage electronic components

.  

 

Installation Instructions 

 

WARNING: - Read and follow installation instructions before plugging or wiring in machine to electrical 

circuit. Warranty will be void if machine is connected to any voltage other than that specified on the 
nameplate serial tag. 

 
1)

 

Machine must be on a flat and level surface. Plug or wire in machine to appropriate voltage as noted 
on the machine serial tag.  Serial tag is located on inside of machine. 

2) 

With water line connected, turn machine power ON (power switch located lower left rear of 
machine). Install Drip tray and drip tray grate under brew area (slide tray between guide rails until 
seated).   

3) 

Tank will automatically fill, and machine will start heating.  If tank does not fill in 8 minutes, a tank 
fill error will occur.  (Note: To reset error power machine on/off with power switch). 

4) 

 Allow 5 to 10 minutes for water in tank to heat to brewing temperature. (Additional water may drip 
into drip tray on initial expansion of water in the tank). This will not occur thereafter. 

5) 

Heater will turn on when tank is at probe level.  When tank noise is no longer heard, machine is 
ready to operate 

6)

 

In higher altitude locations (5000 feet above sea level) the thermostat may have to be 
adjusted lower to prevent boiling: 

 

Summary of Contents for NHW-5

Page 1: ...PN 121586 8 29 2013 1 NHW 5 HOT WATER MACHINE Operating Instruction Manual Model NHW 5 1 800 325 7867 3650 NEW TOWN BLVD ST CHARLES MO 63301 WWW NEWCOCOFFEE COM...

Page 2: ...s Specifications 5 Plumber s Installation Instructions 6 Electrical Hook Up 6 Installation Instructions 6 Operating Instructions 7 Temperature Adjustment 7 Machine Troubleshooting 8 Machine Parts Loca...

Page 3: ...as they are for your protection WARNING DO NOT OVERLOAD CIRCUIT ALWAYS ELECTRICALLY GROUND THE CHASSIS OR ADAPTOR PLUG DO NOT DEFORM PLUG OR CORD FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES KEEP COMBU...

Page 4: ...ranty is limited to replacing or repairing any part or parts which are defective in material or workmanship and returned to our factory shipping cost prepaid No warranty expressed or implied other tha...

Page 5: ...121586 8 29 2013 5 Machine Dimensions Specifications 120 VAC 1600W HEATER 15A USA POWER SUPPLY 120 VAC 1400W HEATER 15A CANADIAN POWER SUPPLY 1 2 GALLON TANK 8 12 OZ CUP SIZE TEMPERATURE RANGE 180 20...

Page 6: ...rements CAUTION Improper electrical installation will damage electronic components Installation Instructions WARNING Read and follow installation instructions before plugging or wiring in machine to e...

Page 7: ...cup or bowl under dispense nozzle Pull down Red Handle on Dispense Nozzle to dispense hot water and release nozzle when finished CAUTION WATER IS EXTREMELY HOT Machine will automatically refill and re...

Page 8: ...ot hot a Temperature setting too low b Heater overload tripped c Defective heater element d Defective thermistor a Adjust temperature setting b Reset hi limit thermostat c Replace heater element d Rep...

Page 9: ...PN 121586 8 29 2013 9 Machine Parts Locator 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18...

Page 10: ...ASY LCD1 HOT 7 121304 DRIP TRAY LCD 1 8 121305 GRID DRIP TRAY LCD 1 9 121576 TNK ASY COMPCT HOT W 1600 10 120898 TANK BODY W INSUL LCD 1 11 111593 THERM MAN VERTAB 221F 25A 12 120928 10 ELE MAIN 1600W...

Page 11: ...PN 121586 8 29 2013 11 Wiring Diagram...

Reviews: