Manual PN 119985 Rev 02-06 Firmware Rev 4
10
20:1 Wiring Diagram
4 1
5 2
6 3
3 1
4 2
6 1
7 2
8 3
9 4
10 5
2 1
2 1
2
1
DP-A
DP-B
CN5
CN3
CN2
CN1
+
-
BK
WH
WH
GY
GY
BK
BN
BK\
WH
BK\
WH
BN
RD
BK
RD
BL
RD
BK
RD
YL
ON
BK
BN
BK
BK
RD
RD
BK\
WH
BK\
WH
RO
PROBE
STANDARD
PROBE
PROBE
SIGNAL IN
BN
YL
ON
THERMISTOR
ASSEMBLY
TANK
HEATER
ELEMENT
HI-LIMIT
THER-
MOSTAT
HEATER
RELAY
TANK ASSEMBLY
COMPONENT
PANEL ASSEMBLY
SWITCH/DISPLAY BOARD
VL/BK
VL/WH
BK
WH
WH
VL/WH
VL/BK
TERMINAL
BLOCK.
OPTIONAL
FOR 120 V
POWER
CORD
HEATER
RELAY
TANK
HEATER
ELEMENT
VL\BK
BK
WH
POWER
CORD
BK
WH
GN
OPTIONAL 240V WIRING
L1
L2
N
VL/BK
VL/WH
VL/BK
VL/BK
BK
RD
RD
FILL
VALVE
TRANSFORMER
PROG
SWITCH
PROG
SWITCH
MAIN
CONTROL
BOARD
100729-2
100731-2
RIB
B
ON CAB
L
E
RIBBON CABLE
WARRANTY
Newco coffee brewers are warranted against defects in workmanship or materials, under normal use, for 90
days from the date of purchase. Brewer parts are warranted against defect for 12 months from date of purchase.
Liability in all events is limited to the purchase price paid and liability under the aforesaid warranty is limited to
replacing or repairing any part or parts which are defective in material or workmanship, and returned to our factory,
shipping cost prepaid. No warranty expressed or implied, other than the aforesaid is made or authorized by Newco
Enterprises, Inc.
Prompt disposition will be made if item proves to be defective, within warranty. Before returning any item,
write or call Newco, or the dealer from whom the product was purchased, giving model number, serial number, and
date of purchase, and describe nature of the defect. If damage was incurred during transit to you, file claim with the
carrier.