background image

O P E R A T O R ’ S   H A N D B O O K

An internal error has occurred.

Switch off the machine. After a delay of
5 seconds switch on again, this should
reset the machine.

If the problem recurs, call a Technical
Service Representative.

The machine has been trying to heat the
water for 20 minutes without success.

This suggests that the over-temperature
reset button has tripped, or the element
has failed.

Press the RED over-temperature reset
button situated on the top right hand side
panel, inside the main front door.

PRESS THE RESET BUTTON.

If the problem recurs after a further 20
minutes,  SWITCH OFF THE
MACHINE,
 and call a Technical
Service Representative.

The lower plate of the brew mechanism
has been lowered or removed.

Switch off the machine.

Open the door, replace and close the
lower clamp plate.

Take care when handling the lower
plate as it has sharp cutting edges!

Switch on the machine.

or

or

Display Messages (cont.)

14

Summary of Contents for Gevalia

Page 1: ...B r e w e r B r e w e r O P E R A T O R S H A N D B O O K...

Page 2: ...handbook contains instructions for the GEVALIA Brewer Please read the handbook before using the machine Keep this fold out page open while reading the Operator s Handbook O P E R A T O R S H A N D B O...

Page 3: ...8 for detail Capsule Bin Over Temperature Reset Button Filling Funnel Capsule Entry Flap Spill Sensor Behind Capsule Bin Display Capsule Entry Slot Cup Fill Position Door Power Cord Water Inlet Fitti...

Page 4: ...or connection to the brewer 3 If installed with a saddle valve the port should have a minimum of 1 8 port hole for up to 25 run and 5 16 port hole for over 25 run 4 Connect water line to plumbing fitt...

Page 5: ...O P E R A T O R S H A N D B O O K Do Not Print This Page Do Not Print This Page...

Page 6: ...r Technical Details Inside Front Cover Important Safeguards 3 Setting Up 4 How to Get a Drink 6 Daily Maintenance 7 Weekly Maintenance 8 Adjusting Drinks Volume 10 Drinks Counter 10 What To Do If Thin...

Page 7: ...O P E R A T O R S H A N D B O O K 2 Part No 792440 1...

Page 8: ...tal surface at a convenient height in a position where it is not likely to be knocked off 4 The Power Cord should never trail from the machine and should always be kept away from hot surfaces and shar...

Page 9: ...display or Release Program button and press Reset button to scroll through options which alternate between Plumbed and Manual until the display reads Press and release Program button to return to norm...

Page 10: ...and Manual until the display reads i e filled by hand into the fill funnel Press and release the Program button to return to normal operation When display shows Pour water into funnel as shown until...

Page 11: ...omatically Add milk and sugar as required 3 Insert capsule pointed end first fully into the slot above the cup station The capsule will be automatically drawn into the machine and will commencebrewing...

Page 12: ...check underneath the brew mechanism to ensure a capsule is not still trapped Remove the offending capsule close the front door switch on the machine and it will reset automatically NOTE This automatic...

Page 13: ...mmed capsule you will now see whether a capsule is jammed inside Carefully remove any jammed capsules with your fingers do not use sharp instruments or tools in the mechanism To unhook the clamp plate...

Page 14: ...leaning simply push in the two plastic lugs fig iii A and the clamp plate should unclip To re assemble push in the two plastic lugs and snap the clamp plate back into position fig v To replace the cla...

Page 15: ...ton to increase the drinks level On reaching maximum the levels will automatically decrease in stages back to minimum Select the desired level then press the program button to return to operating mode...

Page 16: ...ion Most of these problems can be solved by clearing the cause of the fault and pressing the reset button or unplugging the machine from the electrical outlet and then back in again after five seconds...

Page 17: ...NOTE This automatic warning feature will not work on machines mounted on the optional base cabinet The bin inside the cabinet must be checked daily by the key operator Open the door remove the capsule...

Page 18: ...l a Technical Service Representative There is a capsule in the entry flap of the brew mechanism or the capsule entry flap is stuck open Remove the capsule from the entry flap or if the capsule entry f...

Page 19: ...as tripped or the element has failed Press the RED over temperature reset button situated on the top right hand side panel inside the main front door PRESS THE RESET BUTTON If the problem recurs after...

Page 20: ...sule while brewing the brewing cycle was stopped and the capsule was ejected into the bin The customer may have received either a short measure or possibly no drink at all Switch off the machine and a...

Page 21: ...sages see Contents page please contact the Newco customer serice department at Telephone 800 325 7867 Fax 636 925 0029 Outside normal business hours a telephone answering service is available If you w...

Page 22: ...O P E R A T O R S H A N D B O O K...

Page 23: ...O P E R A T O R S H A N D B O O K...

Reviews: