background image

 
 
 

 
 
 
 
 

Head Office 

6  Wincomblee   Road 
Walker  Riverside 
Newcastle upon Tyne 
NE6  3PF 
 
Tel: +44 (0)191 295 0111 
Fax: +44 (0)191 295 0077 
Website: 

www.newarc.co.uk

 

e-mail:   

[email protected]

 

Aberdeen Office 

Unit 23  Kirkhill  Place 
Kirkhill  Industrial  Estate, Dyce 
Aberdeen 
AB21 0GU 

 
Tel: +44 (0)1224  771063 
Fax: +44 (0)1224  724536 

 

Guarantee 

New-Arc  Equipment  Ltd  warrants  that  its  goods  and  services  are  guaranteed  to  meet  the  specific 
performance  under  the  stated  conditions  of  use.  New-Arc  cannot  be  held  responsible  for  general 
wear  and  tear  or  for  failure  occurring  due  to  misuse  or  abuse  arising  out  of  circumstances  outside 
the stated conditions of use. The stated conditions of use are that considered normal industrial prac-
tice and are not exhaustive. Each machine is identified with a unique serial number and accompa-
nied with the guarantee. New-Arc reserve the right to  a) Repair. b) Replace. c)  Authorise the rea-
sonable  cost  of  repair  or  replacement  at  an  approved  New-Arc  service    agent.  d)  Credit  for  any 
purchased equipment  (less reasonable depreciation for actual use and condition) at its entire dis-
cretion. This in no way affects your rights as a consumer. The guarantee is enclosed with each ma-
chine.  
 

 
Waiver 

Whilst  every  endeavor  is  made  to  ensure  the  details  of  this  document  are  correct  at  the  date  of 
print. New-Arc accepts no liability for correctness in respect of any impending change in legislation 
or health and safety requirements. New-Arc also reserve the right to amend the detail of the docu-
ment content without any notification to the consumer. If reference is made to New-Arc while utilis-
ing the document for spare parts purchase or instruction please advise the revision of the document 
to ensure correctness of information.  

 

Summary of Contents for R2500

Page 1: ...ut prior notice R2500 Important Information The R2500 is a 250 constant current welding power source based on IGBT technology The Inverter drive circuitry operates above the audio frequency spectrum making the R2500 virtu ally silent in operation The high operational frequency also means that the R2500 is able to respond quickly to changing arc dynamics making for a very smooth stable arc The R250...

Page 2: ......

Page 3: ...____________________ 6 SECTION 4 OPERATION 4 1 Description of Controls__________________________________________________ 7 4 2 Operation_____________________________________________________________ 7 SECTION 5 FAULT FINDING AND MAINTENANCE 5 1 MMA Welding Problems________________________________________________ 8 5 2 Maintenance__________________________________________________________ 8 SECTION 6...

Page 4: ...thout it s protective cover Keep your clothing and body dry The safe handling of gas cylinders The R2500 uses argon when TIG welding using the TIG300 This is an inert gases and can displace oxygen in the at mosphere leading to asphyxiation Note If dropped the gas cylinder may explode Check the gas cylinder pressure regulator and gas hoses regularly for leaks and discard any suspect item Do not try...

Page 5: ...namics making for a very smooth stable arc The R2500 is capable of TIG welding with the addition of an external TIG control unit TIG300 2 2 Technical Specification SECTION 2 SPECIFICATION Technical data R2500 Input Voltage Range 380 480V 3 phase 50 60Hz Power Consumption 9KVA Input Current at Max Output 12 amps Mains Cable 4 x 2 5mm flexible cable Power Factor 0 95 Degree of Protection IP21 Insula...

Page 6: ...ator switch must be fitted Note See the technical specifications page for cor rect supply information Primary cable length Long cable lengths may reduce the performance of the machine the welding arc may become unstable espe cially at higher currents Ensure the mains cable is not coiled up when you are welding as this will reduce the input voltage to the machine Strip approximately 150mm of insula...

Page 7: ...odes within the current rating of the machine normally up to 5 0mm The R2500 should never be used with arc air gouging or cutting electrodes 4 2 2 MMA Welding with remote control Select welding polarity as in paragraph 4 2 1 Turn the mode switch to remote Plug the control cable supplied with the remote into the remote control socket Plug the remote control onto the other end of the control cable A...

Page 8: ...age Check the condition of the welding cable earth clamp and welding output connectors for damage and any sign of over heating Check the condition of the mains cable an plug Three monthly As per the weekly schedule plus Remove the side panels from the machine and remove the build up of dust and debris from inside the ma chine Either use compressed air at low pressure or an industrial type vacuum c...

Page 9: ...R2500 6 1 Parts Locations SECTION 6 PARTS BREAKDOWN ...

Page 10: ...0127A 8 Auxiliary transformer M00289 9 PM Dix socket M00037 10 Current shunt M00309 11 Capacitors C1 C2 M40108 12 3ph Bridge M60056 13 IGBT PCB M90530 14 IGBT M60073 15 Thermostat M00332 80 16 Cooling fan M00311 17 Diodes D1 D2 M60126 18 25mm Torroids M00089 19 Main transformer M90557 20 Main choke M90556 21 Remote socket assembly M90542 22 n a 23 Small control knob M00033 24 Large control knob M0...

Page 11: ......

Page 12: ...ith a unique serial number and accompa nied with the guarantee New Arc reserve the right to a Repair b Replace c Authorise the rea sonable cost of repair or replacement at an approved New Arc service agent d Credit for any purchased equipment less reasonable depreciation for actual use and condition at its entire dis cretion This in no way affects your rights as a consumer The guarantee is enclose...

Reviews: