NewAir NAC12KWH01 Owner'S Manual Download Page 6

 

newair.com

 

ASSEMBLY INSTRUCTIONS 

1.     Unscrew the slide at the top.

                               

 

 

 

 
 

2.     Remove the slider at the top.                  

 

 

 

 

 

3.    Remove the exhaust hose. 

 

 

 

 
4.    Attach the exhaust hose to 
       the vent. 

 

 

 

5.    To store the exhaust hose, reverse the steps. Remember to put the screw 
back in place. 

Summary of Contents for NAC12KWH01

Page 1: ...Manual v1 0 Portable Air Conditioner OWNER S MANUAL Read and save these instructions SKU NAC12KWH01...

Page 2: ...nstructions 9 Cleaning Maintenance 15 Troubleshooting 16 Limited Manufacturer s Warranty 18 SPECIFICATIONS MODEL NO NAC12KWH01 VOLTAGE 115V FREQUENCY 60Hz POWER CONSUMPTION 1120W 10 5A AIR VOLUME 220...

Page 3: ...Registering your product information online is safe secure and takes less than 2 minutes to complete Alternatively we recommend you attach a copy of your sales receipt below and record the following...

Page 4: ...outlet Closely supervise any children or pets when the unit is in use This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack...

Page 5: ...rtment 4 Carrying handle 12 Air filter air inlet 5 Water funnel 13 Air filter air inlet 6 Horizontal louver 14 Exhaust outlet 7 Vertical louver 15 Air filter air inlet 8 Caster 16 Drainage knob port A...

Page 6: ...NSTRUCTIONS 1 Unscrew the slide at the top 2 Remove the slider at the top 3 Remove the exhaust hose 4 Attach the exhaust hose to the vent 5 To store the exhaust hose reverse the steps Remember to put...

Page 7: ...expelled humid air to build up causing the unit to overheat and shut down The hose may extend from 12 to 59 but for maximum efficiency use the shortest length possible WARNING The length of the exhau...

Page 8: ...window and adjust the length as needed 2 Attach exhaust hose to the kit and slide window so that it is held securely Using the adaptor Wall or Window Adaptor 1 Cut a 6 diameter hole in the wall or wi...

Page 9: ...pressor indicator 8 Timer indicator C Timer button 3 Auto mode indicator 9 Sleep indicator D Temp Down button 4 Cool mode indicator 10 High fan indicator E Temp Up button 5 Fan mode indicator 11 Med f...

Page 10: ...tton to start the unit The preset temp is 75 F If the room temp is higher than this the unit will work in cooling mode If the room temp is lower it will work in fan mode At this time the indicator lig...

Page 11: ...light will turn on accordingly Setting the Timer Press the TIMER button to set the hours of operation 1 24 hours the TIMER sign will light When the set time has been reached the machine will turn off...

Page 12: ...or turn off automatically The Water Full indicator light will turn on and an alarm will sound as well When the tank is full drain the water as shown in the section about drainage You may also use the...

Page 13: ...dicator light will light up and the unit will stop working If the Water Full indicator is on please drain water from the port on the back side of the unit until the light turns off The unit will work...

Page 14: ...ing to empty the tank every so often proceed as follows Remove the drain knob and rubber plug and retain for future use Connect the drain tube supplied to the water outlet as shown and locate the othe...

Page 15: ...all could damage the frame Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter tha...

Page 16: ...ure The unit does not produce adequate cooling The unit is in direct sunlight Close any curtains or move the unit to a more shaded area Too many windows or doors are open Close doors and windows There...

Page 17: ...17 Problem Possible Causes Solution The compressor does not work The compressor has overheated and shut off Wait for temperature to drop and then turn the unit on again...

Page 18: ...supply such as low voltage defective household wiring or inadequate fuses Accident alteration misuse or abuse of the appliance such as using non approved accessories inadequate air circulation in the...

Reviews: