A. INSPECTING AND PREPARING THE WATER HEATER

 

NY7SL thru NY70SL - Remove the cardboard box, which comes packaged with the heater.  

    It should contain the following:  TPI thermostat, T&P valve and a “Tee”, foamed lid and screws.
 

NY9SL - Remove the cardboard boxes, which come packaged with the heater.  One box should

    contain the following:  TPI thermostat, T&P valve and a “Tee”, foamed lid and screws.  The other box  

    should contain the heat exchanger. 

 

B. LOCATION

 

Do not place the water heater where there is a risk of property damage in the event of a leak.

 

Place the water heater on a solid foundation in a clean, dry location nearest the boiler.

 

The water heater should be protected from freezing and water lines should be insulated to reduce  

    energy and water waste.

 

Leave sufficient headroom to service the heat exchanger and electrical controls.

 

Do not install in an area where flammable liquids or combustible vapors are present.

 

CAUTION:  The water heater’s outer jacket is plastic and can melt.

 

Do not install in close proximity to wood burning stove or other high temperature apparatus.

NOTE:

   If Water Heater is Placed On Blocks To Raise It From The Floor,

      Be 

Sure

 to Support The 

Entire

 Bottom With At Least ¾ “ Plywood On The Top Of The Blocks. 

C. PROTECTION FROM WATER DAMAGE

 

 

CAUTION:  All water heaters have a risk of leakage at some unpredictable time.

 

IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE A CATCH PAN OR OTHER ADEQUATE  

    MEANS, SO THAT THE RESULTANT FLOW OF WATER WILL NOT DAMAGE FURNISHINGS OR  

    PROPERTY.  (See Figure 1)

 

 

D. RELIEF VALVE

 

WARNING: A POTENTIAL HAZARD TO LIFE AND PROPERTY MAY EXIST IN ANY WATER  

    HEATER IF AN APPROVED TEMPERATURE-AND-PRESSURE RELIEF VALVE IS NOT  

    PROPERLY INSTALLED.

 

For protection against excessive pressures and temperatures in this water heater, install tempera- 

    ture-and-pressure protective equipment by local codes, but not less than a combination temperature- 

    and-pressure relief valve certified by a nationally recognized testing laboratory that maintains 

 

    periodic inspection of production of listed equipment of materials, as meeting the requirements for  

    Relief Valves and Automatic Gas Shutoff for Hot Water Supply Systems, ANSI Z.-97.  This  

INSTALLATION GUIDELINES

3/4” x 28” x 28” Plywood

Solid Blocks Under Plywood

Summary of Contents for Link NY119SL

Page 1: ...the water heater call your heating contractor When seeking informa tion on the water heater provide Model Number and Serial Number as shown on Rating Label Model Number NY _ _ _ SL Serial Number Inst...

Page 2: ...eralized instructions and procedures cannot anticipate all situations For this reason only qualified installers should perform the installation A qualified installer is a person who has licensed train...

Page 3: ...ghtening Sequence Figure 3 13 Circulator Burner Control Wiring Diagrams 14 Zone Valve Wiring Diagrams 15 Switching Relay Wiring Diagrams 16 How to Obtain Service Assistance 18 Warranty 19 Model and Se...

Page 4: ...o wood burning stove or other high temperature apparatus NOTE If Water Heater is Placed On Blocks To Raise It From The Floor Be Sure to Support The Entire Bottom With At Least Plywood On The Top Of Th...

Page 5: ...in cover plate with holes in flange and plastic o ring housing q WARNING Plastic o ring housing must be properly installed See Figure 3 Failure to do this will void the warranty Insert and secure the...

Page 6: ...I Diagram 2 q Inserting the Temperature Sensor Slide temperature sensor all the way into the immersion well until it contacts the end See TPI Diagram 2 q The sensor will measure temperature adequately...

Page 7: ...vice heater q Not in close proximity to wood burning stove q Where leak will not damage property C PROTECTION FROM WATER DAMAGE q Be sure to make provisions to protect area from water damage if a leak...

Page 8: ...ickly such as children disabled or elderly persons The input of heat into the tank is controlled by an immersion thermostat These automatic controls are set at the factory to maintain a water temperat...

Page 9: ...erature has fallen to the set differential degrees below the temperature set point 5 Reattach cover 6 Reconnect electrical supply 7 Check faucet temperature to verify desired temperature is achieved I...

Page 10: ...10 TPI CONTROL DIAGRAM 1 Indicating Light Temperature Adjust Differential Adjust TPI CONTROL DIAGRAM 2 Screw A...

Page 11: ...OL DIAGRAM 3 Outgoing 24V wires to relay or zone valve Incoming 24V power connection Outgoing 110V wires to circulator Chase Nipple Conduit Incoming 24V power connections NOTE Use proper conduit and c...

Page 12: ...12 FIGURE 1 Installation Using Zone Valves Installation Diagram Using Zone Valves FIGURE 2 Installation Using Circulator Installation Diagram Using Separate Circulator...

Page 13: ...oil Plate Plastic O Ring Housing Tank Flange L Nut Small outside O ring Large inside O ring Proper Tightening Sequence for Top Mount Coil CAUTION Does not require excessive force to seal properly 3 2...

Page 14: ...Switched Hot T T Switching Relay Transformer Thermostat Burner TV W T Z C1 C2 L1 L2 B1 B2 120 Volt Boiler Circulator Temperature Differential Pump TT 24v LED flashing green calling for heat solid gree...

Page 15: ...erature Differential Pump TT 24v LED flashing green calling for heat solid green at temperature red error 20 15 10 5 160 150 140 130 120 110 Probe Temperature Differential Pump TT 24v LED flashing gre...

Page 16: ...rculator 3 Temperature Differential Pump TT 24v LED flashing green calling for heat solid green at temperature red error 20 15 10 5 160 150 140 130 120 110 Probe ZONE 1 ZONE 2 ZONE 3 FUSE 1 AMP ZONE 1...

Page 17: ...ZONE 2 ZONE 3 ZONE 4 ZONE 4 PRIORITY ON OFF ZONE 1 ZONE 2 ZONE 3 ZONE 4 POWER 120 VOLT CIRCULATORS X X END SWITCH ZC ZR INPUT SR 504 ZONE 1 ZONE 2 ZONE 3 ZONE 4 POWER 120 VOLT RELAY 120 VAC INPUT TT O...

Page 18: ...either action has solved your problem contact New Yorker Boiler Co Inc as follows to obtain the num ber of a qualified service person in your area SALES SUPPORT New Yorker Boiler Co Inc P O BOX 10 HAT...

Page 19: ...nt unit will have a warranty of replacement and labor allowance only for the remaining time under the original warranty The Company reserves the right to require the return of the defective unit at th...

Page 20: ...ING EXPRESS LIMITED WARRANTIES ARE THE ONLY WARRANTIES OF ANY KIND EITHER EXPRESS OR IMPLIED THERE ARE NO EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE PERFORMANCE...

Page 21: ...lowing information should be noted At time of installation and retained for Future reference Model No Serial No Date Installed Dealer s Name Address City State Zip New Yorker Boiler Co Inc P O Box 10...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES NOTES NOTES...

Page 24: ...24...

Reviews: