NEW WIDETECH ausclimate WDH-070EBP User Manual Download Page 3

READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE

(refer to the rating plate located at rear of the appliance for the type of refrigerant gas used).

Additional warnings for appliances with R290 refrigerant gas

WARNING

•  R290 refrigerant gas complies with European environmental directives.
•  This appliance contains approx. 0.182 kg of R290 refrigerant gas. The maximum charge 
   amount is 0.3 kg.
•  The minimum rated airflow is 220 m³/h.
•  Use only ingredients recommended by the manufacturer for defrosting or cleaning.
•  Do not use the appliance in a room with continuously operating sources of ignition (eg. open 
   flames, an operating gas appliance or an operating electrical heater).
•  A surface area greater than 9 m² is necessary for the installation, use and storage of the 
   appliance.
•  Do not pierce or burn the appliance.
•  Do not perforate any of the components in the refrigerant circuit.
•  Refrigerant gas may be odourless.
•  Use care when storing the appliance.
•  Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an 
   explosion hazard if the refrigerant comes in contact with electric heaters, stoves or other 
   sources of ignition.
•  Only persons authorised by an accredited agency certifying their competence to handle 
   refrigerants in compliance with sector legislation should work on refrigerant circuits.
•  Maintenance and repairs requiring the assistance of other qualified persons must be carried 
   out under the supervision of specialists in the use of refrigerants.

3

Summary of Contents for ausclimate WDH-070EBP

Page 1: ...NG 2 3 CAUTIONS 4 5 DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION 6 OPERATING INSTRUCTIONS 7 CONTINUOUS DRAINAGE OPTIONS 8 MAINTENANCE EMERGENCY 9 R290 AUTHORISED REPAIRER INSTRUCTIONS 10 13 SPECIFIC...

Page 2: ...nimum of once every two weeks Do not place the appliance near any heating appliance The appliance should be transported upright Any internal water should be emptied before transporting Do not turn the...

Page 3: ...erating electrical heater A surface area greater than 9 m is necessary for the installation use and storage of the appliance Do not pierce or burn the appliance Do not perforate any of the components...

Page 4: ...wer plug If the power cord on this unit is damaged it must be replaced by the manufacturer it s service agent or qualified persons in order to avoid a hazard CAUTIONS CAUTIONS Do not place anything on...

Page 5: ...parts or start a fire Do not place the machine on uneven ground This may cause shaking noise and leakage of water It is dangerous to put anything into the machine Keep the machine away from any type o...

Page 6: ...after displaying the timer the display will change back to current room temperature On Off POWER FAN SPEED High Low TIMER To operate press TIMER select hours the unit will turn off after set hours Wh...

Page 7: ...ket Full light may illuminate if so pull out the water tank check the float lever is able to move freely then return the water tank to the correct position When the water tank is full the indication l...

Page 8: ...may choose this method to allow the water to bypass the water tank and flow directly from the dehumidifier via a drain hose or pump out drain hose The following steps are useful when there are good c...

Page 9: ...mpurities from the air which may hinder the dehumidifying function these should be regularly cleaned The filter is located behind the front grill and can be accessed after removal cleaner or wash it w...

Page 10: ...f fire or explosion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable...

Page 11: ...ipment in use Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall be at the correct rating Replace comp...

Page 12: ...s shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant...

Page 13: ...good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants In addition a set of calibrated weighing scales...

Page 14: ...posed of with household waste Please recycle where facilities exist Check your local authority of retailer for recycling advice SPECIFICATIONS 14 TUV approval Certificate No TUV 025166 EA WDH 070EBP 7...