background image

EAZDesigner

12

Manuak EAZ-TFT

  Selection of the standard designs in the EAZDesigner

Opening an existing design

 

Select the design and click the open button.

 

The program automatically switches to the display area.

4.3.3  Display area

In the display area, you can determine all the settings of your position indicator except for the 
background.

1

 

Floor name

 

Two-digit letter and number combination

2

 

Floor text

 

Additional text for each individual floor 

3

 

Directional arrows and departure arrows (only full image)

 

Can be placed left, right, above or below the floor text. 

Summary of Contents for EAZ 256

Page 1: ...Position indicator MANUAL ...

Page 2: ...Software version 1 3 0 Doc No hb_EAZT TFT_2020 09_en Copyright NEW LIFT Steuerungsbau GmbH 2020 This manual is protected by copyright All rights including those of copying of reproduction of translation and of modification in whole or in part are reserved by the publisher No part of this description may be reproduced in any form or copied with an electronic replication system without written permi...

Page 3: ...omagnetic compatibility EMC 6 2 1 3 Handling electronic assemblies 6 3 EAZ TFT 7 3 1 Technical data 7 3 2 Terminal assignment and configuration 7 3 2 1 Connections 7 3 2 2 Jumpers 8 3 2 3 Configurations via the FST control system 9 3 3 Uploading the software update 10 4 EAZDesigner 11 4 1 Requirements 11 4 2 Installation 11 4 3 Work areas 11 4 3 1 Menu bar 11 4 3 2 Preview area 11 4 3 3 Display ar...

Page 4: ...bols used Symbol abbreviation Meaning EAZ position indicators Delivery condition Settings that are supplied as standard are marked with an asterisk Operational instructions Perform the tasks that follow this symbol in the specified order Warning notice This symbol is located in front of safety relevant information Information notice This symbol is located in front of relevant information 1 2 Notat...

Page 5: ...AZ 256 manual EAZ LCD and EAZ VFD manual Fire recall manual These and other current manuals can be found in the download area of our website at https www newlift de downloads 311 html 1 4 How to contact us If after referring to this manual you still require assistance our service line is there for you Phone 49 89 898 66 110 E mail service newlift de Mon Thurs 8 00 a m 12 00 p m and 1 00 p m 5 00 p...

Page 6: ...ance and commissioning of lift systems ZH 1 312 2 1 2 Electromagnetic compatibility EMC An accredited inspection authority has inspected the FST control system and its components in accordance with the standards thresholds and severity levels named in EN 12015 1995 and EN 12016 1995 The FST control system and its components are immune to electrostatic discharge EN 61000 4 2 1995 immune to electros...

Page 7: ... x 40 2 mm Bolts M4 x 8 mm Preview window aperture 117 2 x 88 4 mm Temperature range Storage transport operation 20 70 C 0 60 C Relative humidity Storage transport operation non condensing 5 95 15 85 JS X1 X2 X5 SD Card JK1 JK2 JK3 JT1 JT2 JHV JCF 140 126 146 10 7 EAZ TFT circuit board marking See appendix for more details 3 2 Terminal assignment and configuration 3 2 1 Connections LON bus The pos...

Page 8: ...lugged open FST E open open plugged FST F plugged open plugged FST G open plugged plugged FST H plugged plugged plugged Jumper JT1 Door side Installation position TI Door side A open Door side B plugged Jumper JT2 No function yet Jumper JVH Installation position Installation position VH Horizontal open Vertical currently not supported plugged Jumper JCF Installation site Installation site CF Landi...

Page 9: ...th E Exit menu and save settings with In addition to the jumper settings the following settings can be made via the FST menu Config EAZ Configuration LON EAZ Config Design selection NEW LIFT provides 16 standard factory designs 0000 dddd Languages German English Setting design and language Config EAZ Configuration LON EAZ Config Select the individual digits with and set the respective digit with a...

Page 10: ...esigns Bit 7 Sprachauswahl 0 Deutsch 1 Englisch Bit pattern for settings of the EAZ TFT in the FST menu 3 3 Uploading the software update Unzip the Update_Vxxx zip file and copy the directory update to the existing SD card There must be at least one EAZ design on the SD card Reinsert the SD card into the EAZ TFT and restart the EAZ TFT The update will run after the boot screen It takes about 1 5 m...

Page 11: ...version of NET should automatically begin to download 4 3 Work areas 4 3 1 Menu bar New Opens new project Open Opens the project folder of the EAZDesigner This is how to open existing projects Save as Opens the window to save the current project Save Saves the current project Create display output Opens the window to select the SD card as the storage medium for a finished project Format SD card Fo...

Page 12: ...ly switches to the display area 4 3 3 Display area In the display area you can determine all the settings of your position indicator except for the background 1 Floor name Two digit letter and number combination 2 Floor text Additional text for each individual floor 3 Directional arrows and departure arrows only full image Can be placed left right above or below the floor text ...

Page 13: ... etc individual floor texts can be added to the floors lobby parking garage ladies department etc The floor text appears below the floor name It is associated with the floor and must therefore be entered for each floor Activate the Floor text checkbox ª The list of setting options now also shows the item Floor text Background image All common image files JPG TIFF PNG can be used as a background If...

Page 14: ...e the values left top right to finely adjust the positioning of the floor name Fixed digit width Because digits have different tracking depending on the font this can lead to an uneven number continuation when running through the floors A fixed width can be set for all digits in order to avoid this Activate the fixed digit width checkbox Fonts A number of fonts are available in the drop down menu ...

Page 15: ...or in the floor text field line breaks are added with If desired change the font style size colour and border To check the settings either click on the respective floor text or on the Auto animation floor text button in the demo window below the display Forced floor name You can replace or supplement the default floor names output by the FST using a forced floor name that you have defined Activate...

Page 16: ...e desired arrow to set its position form and colour settings Position Select an arrow position from the drop down menu left top bottom right Fillings borders Use the Filling method drop down menu to determine whether the arrow is to be displayed proportionally or to fit the area Make the fine adjustments to the borders in the numeric fields Colour settings The characters can also be customised by ...

Page 17: ...position length bar Informational texts Add the desired informational text directly after the event text and separate them with a Example Emergency stop Please remain calm Activate the Flashing text function so that the text and information are displayed alternately To check the settings either click on the respective event or on the Auto Animation events button in the demo window below the displa...

Page 18: ...Set the desired size using the Size bar and position the graphic using the Position bar Shadow effect To give the display elements a 3 dimensional appearance you can add shadowing Here you can change the shadow width softness angle colour and random noise All settings can also be reset using the set Shadow standards button Setting options for shadow effect Relief effect The so called relief effect...

Page 19: ... choose whether you would like to display extended floor texts and determine whether you are using a plain background or a photo other image file Open the arrow layout field and make sure that the editable down arrow checkbox is deactivated an activated checkbox is only necessary if you want different up and down arrows If this is the case please only activate the checkbox after completing the edi...

Page 20: ...26 0mm 88 4mm 44 2mm 44 2mm 146 0mm 126 0mm 117 2mm 58 6mm 58 6mm 4x 5 0mm 4x Kunststoff Abstandsbolzen mit beidseitigem M4 Innengewinde und 23 0mm Länge 2 0 mm 23 0mm 42 0mm 0 1 Alle Toleranzen 0 2mm sofern nicht anders angegeben ...

Page 21: ...NOTES ...

Page 22: ...54427 Kell am See NEW LIFT Neue Elektronische Wege Steuerungsbau GmbH Lochhamer Schlag 8 DE 82166 Gräfelfing 49 0 89 898 66 0 49 0 89 898 66 300 www newlift de info newlift de 49 0 6589 919 540 49 0 6589 919 540 300 www newlift de info newlift sc de ...

Reviews: