2-18
4.
Grasping the handle of the power supply with one hand, pull the power supply part way out of
the slot. Supporting the module bottom with the other, pull the power supply slowly out of the
slot along the guide rails.
Put away the removed power supply in an antistatic bag or the power supply package bag for
future use.
5.
If you are not to install a new power supply in the slot, install a filler panel in the slot to prevent
dust and ensure good ventilation.
Installing and removing a PSR360-56A, PSR560-56D,
PSR720-56A, or PSR1110-56A
The installation and removal procedures are the same for the PSR360-56A, PSR560-56D,
PSR720-56A, and PSR1110-56A power supplies. The following procedure installs and removes a
PSR720-56A power supply.
Installing a power supply
1.
Wear an ESD wrist strap. Make sure the strap makes good skin contact and is reliably
grounded.
2.
Remove the filler panel, if any, from the target power supply slot.
Hold the round hole on the filler panel and pull the filler panel out of the slot gently along the
guide rails.
Figure2-25 Removing the filler panel from the target power supply slot
3.
Unpack the power supply. Make sure the power supply model is as required.
Keep the packaging box and packaging bag for the power supply secure for future use.
4.
Correctly orient the power supply. Make sure the lettering on the power supply is upward.
5.
Align the power supply with the power supply slot. Grasping the handle of the power supply with
one hand and supporting its bottom with the other, slide the power supply slowly into the slot
along the guide rails until the latch of the power supply clicks into the slot.