1.3.6.1 Enter setting ;first pressing “
” then press “
” for 3 secs,the temperature display area display “00”
and blinking display ,input the password (default password “Fb”),then press “
”or “
”to add or
subtract ,press “
”or “
” to confirm ,if the password is wrong then exit current status ; if the password is
correct then enter parameter modification status ,temperature display area display parameters number and
blinking display ,setting temperature area display parameter content ;
1.3.6.2 Setting operation :after entering setting parameters, the parameter number blinking display ,press
“
”or “
”switch line to display each setting parameters number ,then press “
”the parameters
content blinking display ,press “
”or “
” to modify current content ,after finishing press “
” to save
current modification then back to parameters number display status .
1.3.6.3 Exit setting; press “
”to exit parameters setting status or if there is not any pressing keys operation
will automatically exit parameters setting status.
1.3.7 Fault display; when unit fault occurs, the fault blinking display at setting temperature area, recycling
display fault code and temperature, after fault clear the controller recover normal display.
1.3.8 Clock setting:
1.3.8.1 Clock display: in unit shutdown status, long press any keys except “
”, the temperature display area
display current time for one second.
1.3.8.2 Enter clock setting; long press “
” for 3 secs.minutes part of clock area blinking display, means
entering clock setting status
1.3.8.3 Clock setting operation : enter clock setting status ,minutes part blinking display ,press “
”or
“
”to modify minute value .Then press “
”,hours part blinking display ,press “
”or “
”to modify
hour value ,press “
” to save current setting then exit or if there is not any pressing keys operation will
automatically save current setting then exit.
1.3.9.1 There are 2 group timing units, 1
~
2 group ,each timing unit group can set as “timing startup ”timing
shutdown ”.Default setting is “invalid”, means timing startup and timing timing shutdown is same.
1.3.9.2 Enter timing setting :short press “
”,symbol “1 ”
、
“ON ”at left bottom screen blinking display ,minutes
display area blinking means enter “1 unit timing startup ”setting status ,the
minute position blinking
display ,press “
”or “
”to modify minute value ,then press “
” to confirm then enter hour setting ,the