52
Specifications
■
Explosion-proof Specifications
Model
XP-33xxII
Type of protection
Models which use non-rechargeable alkaline AA batteries:
ATEX: II 1G Ex ia da IIC T4 Ga (Other than XP-3380II)
II 1G Ex ia IIC T4 Ga
(XP-3380II)
IECEx: Ex ia da IIC T4 Ga
(Other than XP-3380II)
Ex ia IIC T4 Ga
(XP-3380II)
UL:
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx da ia llC Ga (Other than XP-3380II)
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx ia llC Ga (XP-3380II)
The device has a temperature code of T4 when used with
primary cells or T3 when used with secondary cells.
Models which use rechargeable nickel metal hydride AA batteries:
ATEX:
II 1G Ex ia da IIC T3 Ga (Other than XP-3380II)
II 1G Ex ia IIC T3 Ga
(XP-3380II)
IECEx: Ex ia da IIC T3 Ga
(Other than XP-3380II)
Ex ia IIC T3 Ga
(XP-3380II)
UL:
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx da ia llC Ga (Other than XP-3380II)
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx ia llC Ga (XP-3380II)
The device has a temperature code of T4 when used with
primary cells or T3 when used with secondary cells.
Type of protection for CS, CT, and CH sensors
ATEX: II 1G Ex da IIC Ga
IECEx: Ex da IIC Ga
(Max. input power: 1.3 W)
Ingress protection
IP30
Rating
Power
source
3.0 VDC
Toshiba LR6
x 4pcs
Panasonic LR6X
x 4pcs
Duracell MN1500
x 4pcs
Energizer E91
x 4pcs, or
Varta 4106
x 4pcs
2.6 VDC
New Cosmos HR-3UTG x 4pcs
Ambient
temperature -20
C
to +50
C