TROUBLESHOOTING

NDC-SG Series: Troubleshooting

Fault

Causes

Solution

No power/ 

unit not 

running

The main power switch is turned OFF

Turn main power switch to ON position

No power in the outlet socket

Verify if breaker tripped, verify outlet socket

Poor contact between plug and socket

Verify and repair plug or socket

Power cord unplugged

Plug in power cord

High 

temperature 

iniside 

cabinet

Thermostat set too high

Set thermostat to lower temperature

Cabinet is in defrost cycle

Wait for defrost cycle to finish

Door not properly closed

Close door properly, verify for gasket damages.

Dirty condensing coil

Verify and clean condenser

Condensing fans not working

Verify condenser fan is plugged properly and not damaged

Equipment is near an heat source

Move equipment from heat source to allow proper air flow.

Evaporator coil is iced over

Unplug and empty unit. Leave door open to allow 

evaporator coil to defrost.

Too much goods inside unit

Remove some goods to allow proper air flow.

Improper air circulation

Ensure proper air circulation surrounding the unit

Inside 

cabinet 

water leak

Unit not properly leveled

Verify and level unit left to right and front to back

Drain not properly attached

Verify and properly attach drain hose

Drain frozen

Unplug and empty unit. Leave door open to allow drain hose 

to defrost.

Outside 

cabinet 

water leak

Condensation due to humidity level to high

Clean surface, if possible, find way to reduce humidity level 

surrounding the unit

Condensation water tray overflowing

Locate and empty condensation water tray

Water leaking outside condensation water 

tray

Locate and ensure drain hose is going inside the 

condensation water tray

Noisy unit

Cabinet is not placed on stable surface

Ensure cabinet is located on leveled and stable surface

Loose parts and screws

Locate and tighten loose parts and screws

Compressor 

not working

Temperature setting on controller is too high Lower temperature setting on controller
Too low voltage

Verify power outlet has the proper voltage to operate unit

Controller wiring not properly connected

Verify wiring at back of controller

Before requesting any service on your unit, please check the following points. Please note that this guide 
serves only as a reference for solutions to common problems. Please ask qualified personnel to service. 

11

Summary of Contents for NDC-014-SG

Page 1: ......

Page 2: ...s techniques pg 18 Installation pg 7 Installation pg 19 Operation pg 8 Utilisation pg 20 Control Board Instructions pg 9 R glage du thermostat pg 21 Maintenance pg 10 Entretien pg 22 Troubleshooting p...

Page 3: ...led The unit must be level after it is positioned in its permanent location This ensures proper door alignment on all cabinet adequate condensate water drainage and proper overall refrigeration system...

Page 4: ...mable refrigerant used Do not use mechanical devices to defrost refrigerator Do not puncture refrigerant tubing 9 DANGER Risk of fire or explosion Flammable refrigerant used To be repaired only by tra...

Page 5: ......

Page 6: ...g Dimensions in W x D x H 34 x 24 x 32 44 x 24 x 32 Packaging Dimensions cm W x D x H 86 5 x 61 x 81 112 x 61 x 81 Net Weight 507 lbs 230 kg 558 lbs 230 kg Gross Weight 520 lbs 236 kg 571 lbs 236 kg S...

Page 7: ...sure that there is enough space between the back side of the refrigerator and the wall and that nothing is placed on top of the refrigerator Allow a minimum gap of 100mm at the rear and 50mm at the si...

Page 8: ...nfecting please turn off the power wrap the electrical elements with plastic films and do not wash the internal cabinet directly with water 6 The operation and clean up of the refrigeration compressor...

Page 9: ...or 2 seconds until a flashing number appears in display then release SET 2 The flashing number is the present temperature set point Press UP or DOWN arrows to the desired temperature set point For fur...

Page 10: ...to bottom not side to side After cleaning straighten any bent condenser fins with a fin comb Cleaning the fan blades and motor If necessary clean the fan blades and motor with a soft cloth If it is n...

Page 11: ...unding the unit Inside cabinet water leak Unit not properly leveled Verify and level unit left to right and front to back Drain not properly attached Verify and properly attach drain hose Drain frozen...

Page 12: ...late 48 Front s steel piece for base 16 Left plate for base 49 Air inlet plate 17 Front plate for base 50 Aluminium profile for air inlet plate 18 Rocker switch 51 Mirror nail 19 Wicking Pad 52 Right...

Page 13: ...nts K1 Cooling Switch K2 Lighting Switch UK Temperature controller T 12V Power Adapter LED LED Lamp T1 Toroidal Transformer F1 Evaporation Fan F2 Condensor Fan motor DY Compressor FH Electrical Heatin...

Page 14: ...NO CONSEQUENTIAL DAMAGES NEW AIR is not responsible for economic loss profit loss or special indirect or consequential damages including without limitation losses or damages arising from food or prod...

Page 15: ...ster your unit with New Air Refrigeration simply proivde the following information by email to service distex ca or via the New Air website www newairrefrigeration ca WARRANTY REGISTRATION CARD OWNER...

Page 16: ...voir t positionn e dans son emplacement permanent Cela garantit un alignement correct des portes sur toutes les armoires une vacuation ad quate de l eau de condensation et un bon fonctionnement global...

Page 17: ...pareils m caniques pour d givrer le r frig rateur Ne percez pas la tubulure de r frig rant 9 DANGER Risque d incendie ou d explosion R frig rant inflammable utilis r parer uniquement par un personnel...

Page 18: ......

Page 19: ...es in W x D x H 34 x 24 x 32 44 x 24 x 32 Dimensions int rieures cm W x D x H 86 5 x 61 x 81 112 x 61 x 81 Poids net 507 lbs 230 kg 558 lbs 230 kg Poids total 520 lbs 236 kg 571 lbs 236 kg Roues pivot...

Page 20: ...e le r frig rateur est plac sur une surface niveau Connexion lectrique Si le cordon lectrique n est pas assez long n utilisez pas de rallonge Faites installer une prise plus pr s du r frig rateur par...

Page 21: ...u ce qu un num ro clignotant apparaisse l cran puis rel chez SET 2 Le chiffre clignotant est le point de consigne de temp rature actuel Appuyez sur les fl ches UP ou DOWN jusqu au point de consigne de...

Page 22: ...et le nettoyage du groupe compresseur frigorifique doivent tre respect s r guli rement Lorsqu il y a trop de poussi re dans le condenseur les effets de ventilation et de r frig ration seront influenc...

Page 23: ...lac Vider et d brancher l unit Laisser les portes ouvertes afin de permettre au serpentin de d glacer Trop de marchandises l int rieur de l unit Retirer la marchandise afin d allouer une bonne circula...

Page 24: ...e avant en acier inoxydable pour la base 16 Plaque gauche pour base 49 Plaque d entr e d air 17 Plaque avant pour base 50 Profil en aluminium pour plaque d entr e d air 18 Interrupteur bascule 51 Clou...

Page 25: ...l Components K1 Interrupteur de refroidissement K2 Interrupteur UK Contr le de temp rature T Adaptateur 12V LED Lumi re au DEL T1 Transformateur toro dal F1 Ventilateur d vaporation F2 Moteur du venti...

Page 26: ...ou des dommages sp ciaux indirects ou corr latifs y compris sans limitation les pertes ou dommages r sultant de la d t rioration des aliments ou des produits qu ils soient ou non dus une panne de r f...

Page 27: ...t avec R frig ration New Air veuillez fournir les informations suivantes soit par courriel au service distex ca ou via le site web de www newairrefrigeration ca CARTE D ENREGISTREMENT DE GARANTIE NOM...

Page 28: ...R frig ration New Air NOTES NEW AIR REFRIGERATION 585 AVE MELOCHE DORVAL QC H9P 2T1 WWW NEWAIRREFRIGERATION CA 1 800 567 3620...

Reviews: