V.Ordinary troubles and remedies.
Phenomenon/
Problem Cause
Insp.Content
Remedy
Remark
Red light not functioning
No Electricity
Fuse Broken
Check fuse
Replace fuse
Loose plug and socket
Check for loose
contact
Replace or service socket
With Electricity
Loose red bulb
Check for loose
contact
Tighten the bulb
Broken red bulb
Remove red bulb
Replace red bulb
Green light not functioning
Compressor working
well
Loose green bulb
Check for loose
contact
Tighten the bulb
Broken green bulb
Remove green
bulb
Replace the bulb
Loose thermostat
Check thermostat
Tighten the thermostat
Compressor not working
Loose thermostat
Check for loose
contact
Tighten the thermostat
Thermostat damage
Check for short
circuit
Replace thermostat
Non-stop running of machine
Does not refrigerate well
Thick frost on surface
Check thickness
<=5mm
Defrost time
Door open frequently
Avoid open
Too much food stored
Lessen the quantity.
Refrigerate well
R134a/R600a
Leaked
Set temp.<ambient
temp
Check temp level
“5-6”
Adjust level to “2-4”
Thermostat not
working
Replace
thermostat
Too noisy
Refrigerator installed on an uneven ground
Check universal
wheels
Put on a level and even
ground
Loose screws at condenser or compressor
Check for loose
screws.
Tighten the loose screws
Compressor not working but
red and green light working.
Loose of starting relay or heat preventing socket
Check damaged
contact
Tighten the connection
Compressor damaged
Repair/Service
Compressor
Voltage less than 187V
Check the voltage
level
Use a power regulator