2264ALB Limiter / Compressor

Issue 1

Front Panel Controls

LIM THR, REC, LIM I/O (Limiter Section)

This is a 3-function group of controls comprising the following functions:

LIM

it 

THR

eshold 

The inner grey knob, variable from +4dBm to +15dBm, controls the 

threshold at which the limiting effect takes place.

Limit 

REC

overy

The outer metal knob, a switched attenuator with notched settings from 

50ms to 800 ms, controls the recovery time of the Limiter.  There are 
also two 

Auto

 settings, 

A1

 and 

A2

.

LIM

it 

I

n/

O

ut

Push the inner grey knob to place the Limiter in/out of circuit.  The 

LIM 

I/O

 LED lights when the Limiter is in circuit.

COMP THR, REC, COMP I/O (Compressor Section)

This is a 3-function group of controls comprising the following functions:

COMP

ressor 

THR

eshold 

The inner grey knob, variable from -20dBm to +10dBm, controls the 

threshold at which the compression effect takes place.

Compressor 

REC

overy

The outer metal knob, a switched attenuator with notched settings from 

100ms to 1500 ms, controls the recovery time of the Compressor.  There 
are also two 

Auto

 settings, 

A1

 and 

A2

.

COMP

ressor 

I

n/

O

ut

Push the inner grey knob to place the Compressor in/out of circuit.  The 

COMP I/O

 LED lights when the Compressor is in circuit.

COMP GAIN,  RATIO, LINK (Compressor Section)

This is a 3-function group of controls comprising the following functions:

COMP

ressor 

GAIN

 

The inner grey knob, variable from 0dB to +20dB, controls the make-up 

gain applied to compensate for level lost due to the compression 
process.

Compression 

RATIO

 

The outer metal knob, a switched attenuator, runs from 1.5:1 to 6:1 in 
notched increments, controlling the ratio of the Compressor section.

Control Voltage 

LINK

 

Push the inner grey knob to select whether the control voltage is derived 
internally or externally via Pin 6 of the Lunchbox

TM

 rack buss to allow 

linking with other 2264A LB units.  The LINK LED lights when external 
control is selected.

- 5 -

Summary of Contents for 2264ALB

Page 1: ...2264ALB Limiter Compressor User Manual 527 402 Issue 1...

Page 2: ...info crm fault_report html 2009 2012 AMS Neve Ltd own the copyright of all information and drawings contained in this manual which are not to be copied or reproduced by any means or disclosed in part...

Page 3: ...ASS Switch 9 LINK 9 Insert Mode 10 DIP switch Settings 10 Configuration Examples 11 Unit Specifications 12 Recall sheets 13 In the unlikely event that this unit should malfunction or develop a fault t...

Page 4: ...are more precise than those of a 2254 R Also it has a switchable Slow Attack feature for applications such as Bus Compression The 2264A LB Limiter Compressor has been designed for use in sound broadca...

Page 5: ...on effect takes place Compressor RECovery The outer metal knob a switched attenuator with notched settings from 100ms to 1500 ms controls the recovery time of the Compressor There are also two Auto se...

Page 6: ...h is in the SA Slow Attack position the attack time of the Compressor section is slowed for applications such as bus compression Whe the switch is not in the SA position the attack time is reverted to...

Page 7: ...ing a transmitter Fast attack times should be used with care when recording The point at which the limiting threshold occurs can be varied between 4 dBm and 15 dBm A range of recovery times for the li...

Page 8: ...e range of effects Low ratios operated from a low threshold will preserve the impression of dynamic range while enabling the operator to achieve a significantly better signal to noise ratio when recor...

Page 9: ...terminated This effect arises because the unit constitutes a buffer amplifier having a high input and low output impedance The limiter compressor may be used as a linear amplifier providing both the L...

Page 10: ...to the 1073LB User Manual for details on configuring the 1073LB for insert mode 2264A LB configured for Standalone Mode Factory default settings Standalone Mode Factory Default Left switch block Switc...

Page 11: ...64A LB wired as Insert Signal flow 1073LB 2264A LB 1073LB 2 way insert cable Neve p n NN5749 or 3 way insert cable Neve p n NN5790 with Loopback Plug fitted to S2 socket 1073LB with 1073LB EQ then 226...

Page 12: ...05 b COMPRESS switched IN ratio 6 1 recovery 800ms output level 9dBm 0 2 c LIMIT switched IN recovery 800ms input level 20dBm threshold 4dBm 0 4 Parameters Limit Threshold Variable from 4dBm to 15dBm...

Page 13: ...2264ALB Limiter Compressor Issue 1 Recall sheets 13...

Reviews: