![NeuroTek EyeScan 2000S Operating Instructions Download Page 2](http://html1.mh-extra.com/html/neurotek/eyescan-2000s/eyescan-2000s_operating-instructions_1676403002.webp)
EyeScan 2000S Operating Instructions
Getting Started:
The EyeScan 2000 comes with 5 main components, the light bar, the remote
control, a tripod, headphones, and the AC adapter. The light bar is designed to mount
directly to the tripod. First, connect the tripod to the light bar. If you mount the light bar
on the tripod with the handle positioned parallel to the light bar, you will be able
to adjust the horizontal/vertical axis. If the handle is positioned out the back, you
will not be able to adjust the angle. Next, connect the headphones to the light-bar as
shown. Finally, connect the AC adapter to the light bar and plug the AC adapter to a wall
outlet power source.
Turning on the Power: The on/off switch is located on the back of the light-bar.
When you are ready to start an EMDR session, turn the power switch to the on
position. The lights will make one complete scan and then stop in the center of the light
bar. After finishing your session, turn the power switch off.
The Remote Control: The remote control sensors are located on each end of the light-
bar in the display windows. Reduced sensitivity to the remote control may be
realized if remote control is pointed directly in front of, or in back of the light-bar.
All button functions on the Remote Control are illustrated in the diagram to the right. The
green indicator on the remote control will flash when any button is pushed. If the light fails
to flash, replace the 2 AA batteries in the remote.
To begin scanning press the “Start” button. To stop scanning press the “Stop”
button. The lights will always stop in the center of the light-bar. All modes and settings
may be changed whether scanning or stopped.
The Numeric Display: The EyeScan 2000 has two numeric displays, one conveniently
located on each end of the light-bar. Each 3-digit display will indicate 5 different informa-
tion modes: counter, visual mode, audio, volume and speed. To select the between the
different display modes, press the "Mode /\" or the "Mode \/" buttons repeatedly until
the desired display mode is reached. See display mode diagrams to the right.
Count Display Mode: This is the default display mode when the EyeScan 2000 is first
turned on. To select the count display mode, push the "Mode /\" or the "Mode \/"
buttons until the 3 dots at the bottom of the display window are off. When count
display mode is selected, the completed number of repetitions for the current set are
displayed. The counter will count up to 999 before starting over. When the EyeScan is
stopped between sets, the counter will continue to display the most recent count. When
the next set is started, the counter will reset to zero. The EyeScan always keeps track
of the current count even if the Count display mode is not selected on the display.
Pressing the "/\" or "\/" buttons in count mode will adjust the speed.
Headphones
Tripod
Connects
Here
Visual Display Mode: To select the "visual display mode", press
the press the "Mode /\" or the "Mode \/" buttons repeatedly until
all three red dots are on and the left digit displays a "1". When
"visual display mode" is selected, the right digit will display a "S"
for scan mode or "E" for ends only mode. Press the "/\" or "\/"
buttons to switch between "Scan" or "Ends only" modes.
Tone on/off:To select the "tone mode", press the "Mode /\" or
the "Mode \/" buttons repeatedly until all three red dots are on and
the left digit displays a "2". Press the "/\" or "\/" buttons to turn tone
on or off. When tone is turned on a "O" is displayed in the right
most digit. When tone is turned off a "F" is displayed.
Volume Display Mode: To select the "volume display mode",
press the "Mode /\" or the "Mode \/" buttons repeatedly until all
three red dots are on and the left digit displays a "3". When
AC Adapter
Remote Control
Green Indicator
.
. .
. .
.
.
Start
Stop
Mode /\
Mode \/
/\
\/
NeuroTek Corp
............
Display in
count mode
(dots are off)
Display shows
audio off mode
(dots are on)
Display modes
"volume display mode" is selected, a volume number between 1 & 15 is
displayed. Press the "/\" or "\/" buttons to increase or decrease the volume.
Speed Display Mode: To select the "speed display mode", press the "Mode /
\" or the "Mode \/" buttons repeatedly until all three red dots are on and the left
digit displays a "4". When "speed display mode" is selected, a speed reference number
between 1 & 40 is displayed. Press the "/\" or "\/" buttons to increase or decrease the speed
of alternations.
Battery: The EyeScan 2000 will operate from the integrated 9 volt battery or by
plugging into a wall outlet. The battery door is located on the back side of the light-bar.
When the AC adapter is plugged into the light-bar, the battery is internally disconnected.
Display shows
speed at 25
(dots are on)
1=Scan Mode
2=Tone
3=Volume
4=Speed
Display shows
scan selected
(dots are on)
Display shows
volume at 15
(dots are on)