Spate cleaner TANKO-SF
6 Commissioning
Translation of the original Operating / Installation Instructions 2016/09 Rev.1 31/63
There is a risk of death or severe physical injuries.
DO NOT start cleaning operation while there are persons in the container.
1. Securely close all of the openings on the container (e.g. inspection openings).
2. Switch off moving parts in the container and secure against being inadvertently switched back on or
set in motion.
3. Check to see if there is a safe distance around the container and the surrounding components.
4. Switch on the device (see
section 6.3 Switch-on
5. Check the interfaces on the device for leaks.
6.
NOTE
Danger of collisions with moving parts!
Observe the following steps if components in the container are required to rotate during the
cleaning process:
Start up the surrounding components (e.g. agitators) step by step.
Carefully check that the cleaning head and surrounding components (e.g. agitators) do NOT
collide while moving simultaneously.
7. Make sure that there are no unusual vibrations.
8. Check the device to make sure that it runs quietly and smoothly.
9. Switch off the device (see
section 7.2 Switch-off
6.3
Switch-on Procedure
In accordance with the type of device activation and how it is integrated (e.g. manual or automatic) on
the cleaning plant, the switch-on procedure must be integrated and the following instructions must be
observed when switching on.
WARNING
Risk from sudden, unforeseeable or unauthorized activation of the device (e.g. triggering
of a start command as a result of incorrect operation of a start-up control device)!
There is a risk of death or severe physical injuries.
When commissioning the device, it is imperative to perform the following working steps in
the specified order.
Switch-on procedure
1.
Securely close all of the openings on the container (e.g. inspection openings).
2.
Switch on the supply of cleaning agent (e.g. slowly open the shut-off valve or ball cock).
3.
Check that the supply of cleaning agent is NOT interrupted and the media pressure on
the device is established.
4.
Take suitable measures to secure the supply of cleaning agent to prevent it from
switching off suddenly, unexpectedly or without authorization.