KH 120 |
13
Acoustical controls
Bass:
0,
-
2 .5,
-
5,
-
7 .5 dB
Low-mid: 0,
-
1 .5,
-
3,
-
4 .5 dB
Treble:
+1, 0,
-
1,
-
2 dB
Protection circuitry
Limiter: low, high
Infrasonic filter frequency; slope
30 Hz; 6 dB/oct .
Analog input
Input type
XLR, electronically balanced
Impedance
depending on the position of the output level control
(“OUTPUT LEVEL”):
114 dB SPL
20 k
W
108 dB SPL
10 k
W
100 dB SPL
20 k
W
94 dB SPL
10 k
W
Input gain control (sensitivity)
0 dB to
-
15 dB
Output level control
94, 100, 108, 114 dB SPL
CMRR
>56 dB, 20 Hz to 15 kHz
Maximum input level
24 dBu
Product properties
Power consumption (idle)
20 W
Power consumption (full output AC)
200 W
Dimensions (H x W x D)
277 x 182 x 220 mm (10
7
/
8
" x 7
1
/
8
" x 8
5
/
8
")
Internal net volume/external volume
6 .5 l/9 .7 l
Weight
6 .4 kg (14 .1 lbs)
Drivers – woofer, tweeter
magnetically shielded – 130 mm (5 .25"), 25 mm (1")
Mounting points
2 x M8 on rear panel with depth 15 mm (
5
/
8
")
Cabinet surface finish, Color
painted aluminium, Anthracite (RAL 7021)
Operating conditions
Ambient temperature
+10 °C to +40 °C (+50 °F to +104 °F)
Relative humidity
max . 90 % (non-condensing)
Power supply
100 to 240 V~, 50/60 Hz
Transport/storage conditions
Ambient temperature
–25 °C to +70 °C (–13 °F to +158 °F)
Relative humidity
max . 90 %
In compliance with
Europe
EMC EN 55103-1/-2,
Electromagnetic Environment: Class E4
Safety EN 60065
USA
47 CFR 15 subpart B
Canada
ICES-003
Acoustical measurements, block diagram and pin assignment
Additional technical data such as acoustical measurements, a block diagram of the KH 120 and the pin assignment
of the XLR socket can be found at the end of this operating manual .