NEULOG FLOW LOGGER SENSOR GUIDE

 

 

 

NeuLog flow logger sensor 
NUL-224 

 
The  NeuLog  flow  sensor  can  be  used  for  any  science  experiment  which  involves  a 
liquid flow rate such as in the fields of Environmental Science, Ecology, Earth Science, 
Biology, Chemistry, Physics, etc. 
 
The sensor comes pre-calibrated so you can start experimentation right out of the box 
using this guide.  
 
Among hundreds of possible experimental subjects that can be studied with the NUL-
224  sensor  are:  stream  velocity  and  health,  turbidity,  density  verses  flow  rate,  fluid 
pressure and flow relationships, and many more. 
 
The flow sensor's measurement unit is: 

 

Meters per second (m/s): The SI unit of liquid flow rate. 

 

Connecting to the flow sensor: 

 
The  flow  sensor  takes  measurements  of  liquids  flowing  through  the  flow  probe 
attachment.  There are a few options for connecting the probe attachment to a water 
source: 

 

directly to a faucet using the threaded inlet and outlet pipes 

 

connecting the inlet and outlet pipes to the sample being tested through the 
rubber hosing  

 

connecting the probe to a ruler and submerging it directly into water (a river 
for instance) to take flow measurements. 
 

Please note that our flow logger sensor is meant to be used for liquids and not air. 

 
 
 
 
 
 
 
 

Quick start procedure: 

 

PC or Mac Computer 
 

Materials needed: 
 

 

NUL-224 Flow Sensor 

 

USB-200 USB Module 

 

USB to mini USB cable (included with the USB-200 module) 

 
Your flow sensor needs to be connected to a USB-200 module. The USB-200 module 
then  connects  to  a  computer  via  a  USB  to  mini-USB  cable.    Please  note  that  you 
cannot plug the flow sensor directly into the computer. 
 
The  browser  based  application  can  be  downloaded  for  free  at 

www.NeuLog.com

  as 

well as a full application user guide. 
Choose "Downloads" on the main menu and then choose "Software and Application". 
 

Procedure: 

 
1. 

Install the NeuLog application. 

2. 

Connect the USB-200 module to the PC or Mac. 

3. 

Connect  the  flow  sensor  to  the  USB-200  module  (they  directly  plug  together).  
Please note that no calibration is required for this sensor. 

4. 

Open the NeuLog application by clicking on the shortcut on the screen. 

5. 

Once a flow sensor module box appears on the left side of the screen the probe 
has been automatically identified and you can begin experimentation. 

6. 

If  the  flow  sensor  is  not  automatically  identified  then  click  the  “Search  for 
sensors” icon to find the sensor. 

7. 

Click on the “On-line experiment” icon; this will open a graph below. 

8. 

Cli

ck  on  the  “Module  setup”  button  located  in  the  flow  sensor  module  box  to 

change the sensor's settings if need be. 

9. 

Click  on the  "Experiment setup"  icon  to  change the  experiment  settings  if  need 
be (experiment duration for example). 

10.  The flow sensor will give a live reading in the module box to the left of the screen 

while plugged in. 

11. 

To run an experiment and collect data click the “Run experiment” icon. 

12. 

To end data collection early, click the “Stop experiment” icon. 

 

 
 
 
 