NX-507E / NX-508E AUXILIARY MODULES
5
III.
NX-507E TERMINAL DESCRIPTION
DATA
Connect to the control panel
DATA
terminal. This terminal is the data-signaling terminal to all the
devices on the buss.
COM
Connect to the control panel
COMMON
terminal. This terminal supplies the common side of the
power to the NX-507E board.
POS
Connect to control panel
AUX POWER +
terminal. This terminal supplies power to the NX-507E
board.
TAM
This is an option tamper terminal. To use this feature, connect the normally closed tamper switch
between this terminal and
COM
. If this feature is not used, a jumper must be connected between
this terminal and common.
COM
Connect to the tamper terminal through a normally closed contact.
This terminal can supply up to 100 mA fused separate from the power in the control panel.
AUX
Any power drain from this terminal should be included in total current draw from the
NetworX control panel or NX-320E Power Supply as applicable
.
This allows an isolation
of the power between the main control and remote devices. If a short is created past the
AUX
terminal, those devices will cease to function, but the other devices, including the NX-
507E, will continue to operate. The NX-507E will report this problem to the control for
display on the keypad as an expander power trouble.
7NC
Normally closed dry contact rated 1 Amp at 30 Volts.
7COM
Common dry contact rated 1 Amp at 30 VDC.
REL
A
Y 7
7NO
Normally open dry contact rated 1 Amp at 30 Volts.
RELAYS 1-6
Same as Relay 7 shown above.
OUTPUT 8
Open collector output that switches to GND when activated - capable of up to 100 mA. NOTE: If
device is connected to output, it must see the transition from 13V to GND. Part # 8915 can be used
to connect to Output 8.