MOT-BOX
Rev.
0
3
Connections
3.1
Service connections
The figure below shows the power connections, Ethernet connections and the
expanded beam hermaphroditic fiber connector of the frame.
Figure 3: Connector module for the power supply.
AC
: Connect with a mains cord with an IEC 320 connector to the MOT-BOX.
DC
: Connect with a 4-pin XLR (female) from the external DC power supply to
the
Neutrik NC4MD-L-1
4-pin XLR (male) receptacle of the MOT-BOX.
The following pin-out is applicable:
Pin #1
Negative part of 48VDC supply
Input
Pin #2
Not in use
Pin #3
Not in use
Pin #4
Positive part of 48VDC supply
Input
A green LED will light on the front when the power supply (AC or DC) is in
operation.
Ethernet
: Connect with an RJ-45 plug to the
Neutrik NE8FDV-YK
receptacle of
the MOT-BOX.
Fiber
: Connect your fiber cable with a
Stratos HXMA 4-channel plug
to the
Stratos HXMA 4-channel
expanded beam hermaphroditic fiber receptable of
the MOT-BOX. You may connect the other end of the fiber cable to the
dedicated 1RU frame, MB-FR-1RU. See Chapter 3.3 for more information.
7