background image

NTI UNIMUX SERIES USB KVM SWITCH 

 

12

 

 
 

RS232 CONTROL 

(Optional) 

RS232 enables the UNIMUX to be remotely controlled via RS232.   To control the UNIMUX via RS232 the user has three options: 
 

  write a program that runs on a PC using the Command Protocol (page 14) 

  use the NTI Switch Control Program (page 15) provided on the CD 

  use the SerTest program (page 15) provided on the CD 

 

RS232 Connections and Configuration 

 

Remote Connection 

The RS232 Interface (optional) is designed to meet the RS232C standard and can be controlled from any CPU or other controller 
with an RS232 communications port. The pin-out for the RJ45 connector on the unit is as follows: 

 

RS232 (RJ45) CONNECTOR   

PIN 

SIGNAL 

FUNCTION 

1 - 

No 

connection 

2 - 

No 

connection 

RX+ 

Receive data (TXD at host) 

4 GND  Ground 

5 - 

No 

connection 

TX+ 

Transmit data (RXD at host) 

7 - 

No 

connection 

8 - 

No 

connection 

 

A 5 foot patch cable and two adapters, RJ45-to-DB9 and RJ45-to-DB25, have been provided for connection to most CPUs (see 
page 7).   

Baud Rate 

 
The baud rate can be changed by powering down the unit, changing the 8 position RS232 dip switch on the front of the UNIMUX, 
and then powering back up. This table shows how to set the baud rate. (Fig. 10 shows switches in their factory default position.) 
 
 

DIP 

SWITCH 

BAUD RATE 

   3   

   2     

OFF OFF 

2400 

OFF ON  9600 

(default) 

ON OFF 

19200 

ON ON 

38400 

                                                                                                                 Figure 10- RS232 dip-switches 

 

 

Unit Address and Loop Back 

To allow multiple units to be controlled from a single CPU serial port, the RS232 control interface is designed to allow "daisy 
chaining" up to 15 units. By setting the appropriate RS232 dip switches, each unit can be given a unique address (1-15). Then the 
unit will only respond to commands on the bus if its address is embedded in the command.  Use the following table to set the unit 
address.  
 

 

RS232

1

8

ON

Summary of Contents for NTI High Density DVI USB KVM Switch UNIMUX-DVI-x

Page 1: ...04 2008 UNIMUX DVI x USB DVI KVM Switch Installation and Operation Manual UNIMUXTM Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www network...

Page 2: ...c 1275 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in...

Page 3: ...sta 15 SerTest RS232 Interface Test Program 15 Main Options 15 KEYBOARD FEATURES 17 Keyboard To Computer Translation 17 Translation Capabilities 17 Translation Tables 17 International Sun Keyboards 18...

Page 4: ...User Input Devices Supported USB keyboard with Windows layout USB keyboard with SUN layout USB keyboard with MAC layout USB Mouse up to 3 buttons USB IntelliMouse scrollwheel USB Hub Mouse Trak track...

Page 5: ...Technologies Inc by calling 800 742 8324 800 RGB TECH in the US and Canada or 330 562 7070 worldwide DEFINITIONS USB Composite Device A USB device that contains multiple endpoints each representing i...

Page 6: ...switch address when RS232 is used 7 MONITOR HDMI Type A female connector for connection of the user DVI video monitor 8 5VDC power input connector for attachment of the AC adapter 9 RS232 optional RJ...

Page 7: ...holes in the sides of the NTI switch Tighten the screws securely Figure 1 Secure rackmount ears to switch 2 Install 4 captive nuts not supplied to the rack in locations that line up with the holes in...

Page 8: ...ymbol on the front of the UNIMUX 4 Connect the male USB type A connector on the mouse cable to the remaining USB type A female connector labeled with the USB symbol on the front of the UNIMUX Figure 4...

Page 9: ...U 2 and VIDEO 2 connectors etc Figure 5 Connect each CPU 7 Connect the AC adapter to the UNIMUX See Fig 6 below Figure 6 Connect the AC adapter Rear View of UNIMUX DVI 8 CPU 1 CPU 2 CPU 3 CPU 4 CPU 5...

Page 10: ...connect the adapter to the RS232 port on the control terminal Follow the instruction under RS232 Control on page 12 for configuration and use of the RS232 control feature Figure 7 Connect RS232 contro...

Page 11: ...A female ports See Features and Functions on page 3 item 4 A USB hub single or multi port can be used provided only USB input devices are plugged into it Only a USB Windows or SUN keyboard or USB mou...

Page 12: ...ctly the CPU to which the user is connected through the UNIMUX Keyboard Control Keyboard control of the UNIMUX can be achieved using Command Mode below The keyboard can be used to control all function...

Page 13: ...t use the Backspace key Normal Mode When all of the UNIMUX mode LEDs are OFF the user is in Normal Mode controlling the CPU to which the user is connected through the UNIMUX No Sun Sleep Mode Note It...

Page 14: ...elgian 15 Japan Katakana 28 Swiss German 03 Canadian Bilingual 16 Korean 29 Switzerland 04 Canadian French 17 Latin American 30 Taiwan 05 Czech Republic 18 Netherlands Dutch 31 Turkish 06 Danish 19 No...

Page 15: ...nsmit data RXD at host 7 No connection 8 No connection A 5 foot patch cable and two adapters RJ45 to DB9 and RJ45 to DB25 have been provided for connection to most CPUs see page 7 Baud Rate The baud r...

Page 16: ...erial adapter provided with the RS232 option and the CPU as shown in Fig 11 Figure 11 RS232 connection with Matrix Y 1 cable Figure 12 Pinout of Matrix Y 1 cable Unit 1 Source 2 3 3 3 5 5 5 2 2 7 8 1...

Page 17: ...CR IP CR Read Connection For Output User Port to Input CPU Port RS SW CR Internal Reset RU SW CR IP OP CR Read Unit Size SS SW 00 CR Disable Autostatus feature see below SS SW 01 CR Enable Autostatus...

Page 18: ...Test Program This software allows a user to test the functions of an NTI server switch matrix switch or Multi user Multi platform Single user switch RS232 interface The SerTest program is automaticall...

Page 19: ...ns into switch memory bank command for all switches h Restore All Units I O Connections from Units Memory not applicable to this model restore the connections from switch memory bank command for all s...

Page 20: ...nality Full functionality except Application Key Apple Pro Keyboard Extra keys emulation Extra Keys not supported Eject Mute Volume Volume Full functionality Sun Mouse Full functionality Full function...

Page 21: ...et the UNIMUX to indicate the international keyboard identification number to the CPU by following the instruction on page 11 Enter Enter Ctrl Shift Shift Caps Lock Tab Esc Ctrl Alt Backspace Num Lock...

Page 22: ...chaining 12 definitions 2 devices supported 1 features 3 front panel control 9 Installation 5 international keyboard layouts 18 Keyboard control 9 keyboard features 17 keyboard translation 17 limitat...

Reviews: