OSD CONTROL 

(Optional) 

OSD superimposes a menu system on the user’s video screen with a list of all connected CPUs. OSD allows CPUs to be named 
(with up to 12-character names).   OSD then allows selection of CPUs by that name.  Connected CPUs can be listed by name or 
by port number. OSD Search Mode enables the user to type in the first few characters of the CPU's name and the OSD will locate 
it.  Help screens assist with all OSD functions.  

Security Option 

 
The security option of the OSD Control enables an administrator to control access to the CPU ports for each user.   Up to 24 users 
can be created.   These users have controlled access to any CPU.   Only the administrator can activate or deactivate the security 
features.  Security can be activated from the Maintenance Mode menu (page 16) with a successful administrator login for 
verification purposes.  Furthermore, the administrator can set a maximum idle time value after which the current user will be 
logged out and the login screen displayed.  This time out does not function while the OSD is active.  The current security status, 
idle time out, and scan dwell time are all saved and will be restored whenever power to the switch is cycled OFF, then ON. 

Enabling the Security Feature 

 

To enable the security feature the administrator must first enter Command Mode from the keyboard using the sequence <Ctrl> + 
<`> (accent key).  The OSD menu will automatically appear on the monitor in addition to illuminating the Command Mode indicator 
LED on the KVM switch.   This provides a visual way to control the KEEMUX using the keyboard, monitor, and mouse.    

 
 
 

The administrator

 , when setting the KEEMUX up for the first time, may want to proceed directly to the ADMINISTRATION 

Mode by typing <CTRL> + <M> , then <A>,  and then <Y>. 

  

 
  The factory settings are: 
 

 

default user name = ADMINISTRATOR 

 

default password  = ADMINISTRATOR 

 
FYI:  The user name for administrator cannot be changed from "ADMINISTRATOR"  

 
Once logged-in, follow the instructions on pages 11 and 12  for setting up users and changing the administrator password.  Once 
the password is setup, if it is lost or forgotten, the administrator will have to contact NTI for assistance on clearing the password 
and set it up again.    Within the ADMINISTRATION Mode the administrator can setup each of the users and the limitations of their 
use of the individual CPUs on the system.      

 

When a standard user powers up the system a security screen may appear as setup by the administrator. 

   The user will 

need to login to the system by following the instructions below for the USER LOGIN.    If the user does not know the appropriate 
user name and password (setup by the administrator), contact the system administrator for this information.    Once logged-in a 
user can follow the Command Functions described on page 15 to control the system of CPUs within the limitations as set by the 
administrator.   
 

User Login Mode 

 

User Login Mode requires a user to login with a user name and password from the list created by the administrator.   Access to 
the functions of the KEEEMUX will not be allowed until a user has logged in.  

 

Function:  

 

 

   Keystroke: 

 

Adds a character to the 
user name/password 

 

Removes previous character 
from the user name/password 
 
 
 
 

A-Z

0-9

(Type any alphabetical or numeric character)

Backspace

Summary of Contents for KEEMUX P12

Page 1: ...te 7 2 2007 KEEMUX Px PS 2 KVM Switch Installation and Operation Manual KEEMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www networktech...

Page 2: ...al system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive Aurora Oh...

Page 3: ...ministrator Password 11 User Name List 12 System Access List 12 User Access Functions 13 OSD Command Mode 13 Scan Mode 14 Broadcast Mode 14 Normal Mode 14 Edit Mode 15 Search Mode 16 Maintenance Mode...

Page 4: ...ator password change 11 Figure 10 Command Mode menu 13 Figure 11 Press Ctrl for more functions 14 Figure 12 Edit Mode screen 15 Figure 13 Search Mode screen 16 Figure 14 Maintenance Mode screen 16 Fig...

Page 5: ...nected CPUs add A to the part number i e KEEMUX Px A Dual Video option supports CPUs with two video outputs Add DV to the part number i e KEEMUX Px DV See our catalog visit our website at http www net...

Page 6: ...ale connectors for connection of device cable s from CPU s 10 PS 2 DEVICES 6 pin miniDIN female connectors for connection of user device s keyboard mouse 11 DAISY In Out for attaching interface cables...

Page 7: ...er the system back up If it is necessary to replace one PS 2 keyboard with another one the keyboard can be hot swapped without powering down Refer to Fig 1 for instructions on proper keyboard dip swit...

Page 8: ...n miniDIN Male Connector VEXT xx MM Rear View of PS 2 CPU 15HD Male Video Connector 15HD Female Video Connector 6 pin miniDIN Female Connectors Port assignments KEEMUX P4 5VDC 2A V I D E O 4 V I D E O...

Page 9: ...16 port switches can be used as slave units c Up to 8 slave units may be connected to form a maximum system size of 152 ports 1 x 32 port master 8 x 16 port slaves d Slave units must be added to the m...

Page 10: ...slave 2 to master s VIDEO 2 and CPU 2 KEYBOARD and MOUSE etc See Fig 6 below Figure 6 Cable connections for cascading About Table 2 These switch settings are used by the slave s to establish its iden...

Page 11: ...tch on the front panel of the KEEMUX will connect the selected CPU to the keyboard monitor and mouse Holding down any front panel touch switch for more than 2 seconds will cause the KEEMUX to cycle th...

Page 12: ...g the KEEMUX as detailed below When the COMMAND LED is illuminated all 3 status lights on the keyboard will illuminate to indicate that Command Mode is enabled and the following functions are availabl...

Page 13: ...illuminate and remain ON while in Scan Mode The port with the CPU powered ON remains active while in use When the switch becomes idle for the configured time out period default time out period is 5 s...

Page 14: ...s provides a visual way to control the KEEMUX using the keyboard monitor and mouse The administrator when setting the KEEMUX up for the first time may want to proceed directly to the ADMINISTRATION Mo...

Page 15: ...istration Mode and return to previous mode Administrator Password To change the administrator password press C from the Administration Mode menu The administrator is able to change the administrator p...

Page 16: ...sword Exit the User Name List and return to previous mode System Access List The System Access List displays a list of numbers representing the ports so the administrator can change access rights to t...

Page 17: ...ol the KEEMUX using the keyboard monitor and mouse The list below describes the command functions available from the keyboard within the OSD mode of control after entering into Command Mode and while...

Page 18: ...e switch becomes idle for the configured time out period default time out period is 5 seconds the switch will connect to the next powered ON CPU port See Command Mode section above for configuring the...

Page 19: ...ystroke Move cursor one position to the right Move cursor one position to the left Previous port Next port Selects the first port on the switch Selects the last port on the switch Figure 12 Edit Mode...

Page 20: ...position to the left in search name Select previous port Select next port Figure 13 Search Mode screen Add a character to the search string and select the best matching CPU name Exit Search Mode retu...

Page 21: ...st of commands with a short explanation of their function These lists are organized in pages for each mode i e COMMAND EDIT SEARCH and HELP To enter Help Mode press F1 from Command Mode The following...

Page 22: ...s bypassed and TXD and RXD are the only active signals A straight through DB 9 serial cable not null modem see specifications on page 26 will work for most CPUs To daisy chain multiple units a Matrix...

Page 23: ...N OFF ON 5 OFF ON ON OFF 6 OFF ON ON ON 7 ON OFF OFF OFF 8 ON OFF OFF ON 9 ON OFF ON OFF 10 ON OFF ON ON 11 ON ON OFF OFF 12 ON ON OFF ON 13 ON ON ON OFF 14 ON ON ON ON 15 Note In order to connect mul...

Page 24: ...r up configuration FORMAT RS AA CR RS reset unit command followed by at least one space AA unit address if 00 all units on the bus will be reset and no response will be returned RESPONSE CR if command...

Page 25: ...NTI server switch matrix switch or Multi user Multi platform Single user switch RS232 interface The SerTest program is automatically loaded when installing the MATRIX SWITCHER S CONTROL PROGRAM as des...

Page 26: ...s Memory not applicable to this model restore the connections from switch memory bank command for all switches i Change All Units Baud Rate 9600 COM1 change RS 232 Baud rate of all switches the curren...

Page 27: ...cate Follow the instructions under CONFIGURING THE JUMPER BLOCK on page 24 to disable the desired mode s If the unit is in a plastic case the digital board is located on the bottom of the case requiri...

Page 28: ...pply a jumper across the appropriate pins to disable the desired mode s according to the chart below Pin Designation Mode KCMD Command Mode BRDC Broadcast Mode SCAN Scan Mode Note Putting a jumper acr...

Page 29: ...UX switch and two user monitors to be connected to view both sets of video signals Both monitors must be of the type VGA multi scan Figure 22 Connections for video cables on the KEEMUX P4 DV Rear View...

Page 30: ...se driver was loaded PROBLEM No Keyboard Activity after running shutdown program on IBM PowerServer 220 SOLUTION 1 Select a different port from the front panel buttons 2 Turn power OFF to PowerServer...

Reviews: