background image

 

ETH1000MC

 

Rev. 6

 

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 - Fax: +47 33 48 99 98 

8 Status 

indicators 

8.1 Front Panel LEDs 

The status of the module can be easily monitored visually by 
the LED’s at the front of the module 

LED 

Description  Green light 

Yellow light 

Red light 

No light 

STAT Module 

status 

Module self-test is 
OK and power is 
present. 

 

 

Module initialising 
(takes approx. 2 sec). 

 

The laser is turned off.

 

Module is faulty (fuse 
blown, laser failure, 
laser APC out of lock, 
etc). The card needs 
factory repairment. 

Module has no 
power. 

LOS Loss 

of 

optical 
signal 

Optical input signal 
present. Note: This is 
an optical 
measurement, a green 
light does not imply 
that there exists a 
valid Ethernet signal 
on the optical input. 

 

 

No optical input 
signal. 

 

Check fibre 
connection. 

 

Check card in 
opposite end. 

 

LINK 

Ethernet link  Ethernet link to 

opposite end 
established at 
1000Mbit 

Ethernet link to 
opposite end 
established at 
10 or 100Mbit 

 

Ethernet link to 
opposite end 
not established. 

ACT Ethernet 

activity 

Flashes when 
Ethernet packets are 
sent over the fibre 
link. When the 
Ethernet activity is 
high, this will be on 
continuously. 

 

 

The fibre link is 
idle, no packets 
are sent on the 
link. 

E-mail: [email protected] - Web: http://www.network-electronics.com/ 
Technical specifications are subject to be changed without notice. 

8

 

Summary of Contents for Flashlink ETH1000MC

Page 1: ...network electronics com Gigabit Ethernet Media Converter Rev 6 Flashlink User Manual ETH1000MC...

Page 2: ...2 1 Revision history The latest version is always available in pdf format on our web site http www network electronics com Revision Date Description 6 2007 10 26 New front page and removed old logo 5...

Page 3: ...tory 2 2 Index 3 3 Versions 4 4 Overview 4 5 Specifications 5 6 Laser options 6 7 Connector module 7 8 Status indicators 8 8 1 Front Panel LEDs 8 8 3 Dip switches 9 9 Laser safety precautions 10 10 De...

Page 4: ...has one electrical Ethernet port and one fibre transceiver port receiver fibre connector and transmit fibre connector The speed on the electrical connector is dependent of the DIP switch setting Spee...

Page 5: ...ngle mode 9 125um compatible Return loss 40dB with single mode fibre Detector damage threshold 1dBm Max input power 6 dBm Connector SC UPC Optical output Transmission circuit fibre Single Mode Light s...

Page 6: ...Bm ETH1000MC C1310 0dBm 1310 6 nm DFB 0 dBm Better than 25 dBm ETH1000MC C1330 0dBm 1330 6 nm DFB 0 dBm Better than 25 dBm ETH1000MC C1350 0dBm 1350 6 nm DFB 0 dBm Better than 25 dBm ETH1000MC C1370 0...

Page 7: ...mounted at the rear of the sub rack 7 1 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is...

Page 8: ...of optical signal Optical input signal present Note This is an optical measurement a green light does not imply that there exists a valid Ethernet signal on the optical input No optical input signal...

Page 9: ...When DIP switch 1 2 and 3 are all on or all off highest speed possible will be used when link connection Switch 1 disables 10Mbit connection when DIP is closest to board edge Switch 2 enables disables...

Page 10: ...NECTING DISCONNECTING FIBRE PIGTAILS ENDS NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER FIBRE NEVER USE MICROSCOPES MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBRE END USE LASER SAFETY GOGGL...

Page 11: ...by complies with the Electromagnetic Compatibility Directive 89 336 EEC 11 General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performance speci...

Page 12: ...www network electronics com Technical specifications are subject to be changed without notice 12 12 Product Warranty The warranty terms and conditions for the product s covered by this manual follow t...

Page 13: ...alculated is not finalised at the time of writing See http www aeanet org GovernmentAffairs qfLeOpAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of the draft guidance For our own products N...

Page 14: ...for 50 years 16 Recycling information Network Electronics provides assistance to customers and recyclers through our web site http www network electronics com Please contact Network Electronics Custo...

Reviews: