4
Fig 2. Z806 Wiring Diagram
Input power port:
Refer to Fig. 1, mark 1 and 2 are input power ports which can support input power range from AC
100V-240V
50/60HZ
Output power port:
Main PCB Board carries 2 relays that the control terminal and the controlled terminal is electrically
isolated.
Reference numeral 3,4,5,6 four terminals are output port interface of relays. Numeral 3,4 port to
connect one relay output switches at both ends. Two terminals are turned on and off by controlling
the relay inside the machine. And they are galvanically isolated from other parts of the lines on the
board (ie, here are dry contact outputs).
Numeral 5,6 port interfaces to connect one relay output switches at both ends. Two terminals are
turned on and off by controlling the relay inside the machine. And they are galvanically isolated
from other parts of the lines on the board (ie, here are dry contact outputs).
4.1 Join into ZigBee network
In order to communicate in ZigBee network, join Z806 into the network as below steps:
①
Power on Z806, it will search network automatically.
②
If there are coordinator or router sharing same channel in the network and allowing other
devices to join. Z806 will join the network automatically.
③
After joining into ZigBee network successfully, the network indicator will stay on. Otherwise,
the network will stay off.