![netvox RB02I User Manual Download Page 7](http://html1.mh-extra.com/html/netvox/rb02i/rb02i_user-manual_1675191007.webp)
6
5.
Data Report
Data report configuration and sending period are as follows:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report along with an uplink packet including alarm status and battery voltage
when it joins the network.
The device sends data with default configurations before any new configuration is done.
Default setting:
MaxTime:Max Interval = 60 min=3600s
MinTime:Min Interval = 60 min =3600s
BatteryChange: 0x01 (0.1V)
Emergency alarm:
When emergency button is pressed that report “1”
When emergency button is not pressed that report “0”
Please refer to Netvox
LoRaWAN Application Command document
and
Netvox LoRa Command Resolver
http://www.netvox.com.cn:8888/page/index