R72632A   

 

 

 

Wireless Soil Nitrogen / Phosphorus / Potassium Sensor 

 

 

 

 

 

 

Wireless Soil NPK Sensor 

 
 

 

R72632A 

User Manual 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

Copyright©Netvox Technology Co., Ltd. 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in 

strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX 

Technology. The specifications are subject to change without prior notice. 

Summary of Contents for R72632A

Page 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties i...

Page 2: ...ontent 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 6 Installation 7 7 Important Maintenance In...

Page 3: ...ely waterproof which greatly facilitates the customer s systematic evaluation of soil conditions LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and low...

Page 4: ...can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayen...

Page 5: ...ice verification information on the gateway or consult your platform server provider Function Key Press and hold for 5 seconds Restore to factory setting Turn off The green indicator flashes 20 times...

Page 6: ...he data transmission cycle of the device is subject to the burning configuration and there is no minimum time The value of ReportMaxTime should be greater than or equal to 60 seconds 3 In order to mak...

Page 7: ...2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes Example o...

Page 8: ...ltiple times to obtain the average value within a small range of a measurement point 2 Buried measurement method Dig a pit with a diameter of 20cm vertically insert the sensor steel needle horizontall...

Page 9: ...r assembly will be affected 7 Important Maintenance Instruction The device is a product with superior design and craftsmanship and should be used with care The following suggestions will help you use...