4
Data Report
The device will send a version package report immediately after powering on the device.
The device has no operation until any configuration is done.
The device sends a down-link command configuration with LOLAWAN for the data that needs to be sent
through the R232 and sends the data received by the R232 to the gateway.
The device sends a down-link command with LoRaWan to send the data periodically.
When the RS232 interface of the R718PDA receives the serial port data sent from the RS232 device connected
to it, it will actively report the received data to the gateway in the format of 87+ReceiveData.
The data report can be decoded by the Netvox LoraWAN Application Command document and
http://www.netvox.com.cn:8888/page/index
Data Report Cycle Configuration Example:
Configure device cycle Period = 30s
Downlink: 03001E
Device returns:
8300 (configuration successful)
8301 (configuration failed)
(1) Read device parameters
Downlink: 04
Device returns:
84001E (current device parameters)
Data Report Configuration Example:
Description
Device
CmdID
NetvoxPayLoadData
SetPollSensorPer
iodReq
R718PD
A
0x03
Period(2Byte
,
Unit
:
1s)
SetPollSensorPer
iodRsp
0x83
Status(0x00_success)
GetPollSensorPe
riodReq
0x04
GetPollSensorPe
riodRsp
0x84
Period(2Byte
,
Unit
:
1s)
Description
Device
CmdID
NetvoxPayLoadData
SetPollSensorR
awCmdReq
R718PDA
0x05
SensorRawCmd
SetPollSensorR
awCmdRsp
0x85
Status(0x00_success)
GetPollSensor
RawCmdReq
0x06