5. Data Report

The device will immediately send a version report report and soil moisture, soil conductivity and report data of soil temperature and voltage values;

The device sends data in the default configuration before any configuration is done.

Maximum time: Max Interval

Note: The device send data cycle has been programmed to be correct. There is no minimum time supported.
R718PB15A defaults Max Interval = 60min.

The R718PB15A device does not support the ReportChange function. That is, the configuration is invalid. The sent report data string is always sent
according to the ReportMaxTime cycle.

Note: The real data sending cycle will be programmed before shipment.

R718PB15A Report data type: soil moisture, soil conductivity and soil temperature.

Data report configuration and sending period are as following:

Configure device parameters MaxTime = 1min

Downlink: 01580000003C0000000000
The device returns:

8158000000000000000000 (Configuration succeeded)
8158010000000000000000 (Configuration failed)

Read device configuration parameters

Down: 0258000000000000000000
The device returns:

82580000003C0000000000 (device current configuration parameters)

Description

Device

Cmd

ID

DeviceTy

pe

NetvoxPayLoadData

ConfigReportRe

q

R718PB15

AA

0x01

0x58

Reserved (2bytes Unit:s)

MaxTime(2bytes Unit:s)

Reserved

ConfigReportRs

p

0x81

Status(0x00_success)

Reserved (8Bytes,Fixed 0x00)

ReadConfigRepo

rtReq

0x02

Reserved (9Bytes,Fixed 0x00)

ReadConfigRepo

rtRsp

0x82

MinTime(2bytes Unit:s)

MaxTime(2bytes Unit:s)

Reserved