4
5. Data Report
The device will immediately send a version packet report along with an uplink packet including soil moisture, soil temperature and soil electrical
conductivity values.
The device sends data in the default configuration before any configuration is done.
MaxTime : Max Interval = 15 min (default)
MinTime : None
Note:
(1)
The device report interval will be programmed based on the default firmware which may vary.
(2)
Mintime and ReportChange are not supported by R718PB14 (Invalid configuration)
(3)
Report cycle will be based on Report Max Time period when sending data packet.
(4)
Data packet:
soil moisture, soil temperature and soil electrical conductivity
(5)
It would take about 3 seconds for the soil sensor to sample and process the collected value if you were to manually trigger the device by
pressing the button, please be patient.
Data report configuration and sending period are as following:
(1)
Configure
device parameters MaxTime = 1min
Downlink: 01580000003C0000000000
The device returns:
8158000000000000000000 (Configuration succeeded)
8158010000000000000000 (Configuration failed)
(2)
Read
device configuration parameters
Downlink: 0258000000000000000000
The device returns:
82580000003C0000000000 (device current configuration parameters)
Description
Device
CmdID
Device
Type
NetvoxPayLoadData
ConfigReport
Req
R718PB14
0x01
0x58
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
ConfigReport
Rsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)