background image

 

 

5. Data Report 

 
The device will immediately send a version packet report along with an uplink packet including soil moisture, soil temperature and soil electrical 
conductivity values. 
 
The device sends data in the default configuration before any configuration is done. 
 
MaxTime : Max Interval = 15 min (default) 
MinTime : None 
 
Note:   

(1)

 

The device report interval will be programmed based on the default firmware which may vary. 

(2)

 

Mintime and ReportChange are not supported by R718PB14 (Invalid configuration) 

(3)

 

Report cycle will be based on Report Max Time period when sending data packet. 

(4)

 

Data packet:

 

soil moisture, soil temperature and soil electrical conductivity 

(5)

 

It would take about 3  seconds  for the soil  sensor to sample and process the collected value if you were to manually trigger the  device by 
pressing the button, please be patient. 

 

Data report configuration and sending period are as following:

 

 

 

 

(1)

 

Configure

 device parameters MaxTime = 1min 

 

       Downlink: 01580000003C0000000000 
       The device returns: 
              8158000000000000000000 (Configuration succeeded) 
              8158010000000000000000 (Configuration failed) 
 
(2)

 

Read

 device configuration parameters 

 

       Downlink: 0258000000000000000000 
       The device returns: 
              82580000003C0000000000 (device current configuration parameters) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description 

Device 

CmdID 

Device 

Type 

NetvoxPayLoadData 

ConfigReport

Req 

R718PB14 

 

0x01 

0x58 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

Reserved   

(5Bytes,Fixed 0x00) 

ConfigReport

Rsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes,Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

Reserved   

(5Bytes,Fixed 0x00) 

Reviews: