5. Data Report
The device will send a version package report immediately after power-on. Then, it will send a report
data with the concentration of carbon monoxide
after it is powered on for 20s
.
The device sends data according to the default configuration before any other configuring.
Default setting:
MaxTime: Max Interval = 3min = 180s
MinTime: The MinTime configuration is not available.
*But the software has restriction, MinTime must be configured a number greater than 0.
Note:
1.
The cycle of the device sending the data report is according to the default.
2.
R718PA1 reports the concentration of carbon monoxide.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)