5
data report configuration and sending period are as following:
Remarks: Min Interval depends on the real order.
5. Restore to Factory Setting
R718DB2 saves data including network key information, configuration information, etc. To restore
to factory setting, users need to execute below operations.
1.
Press and hold function key for 5 seconds till the green indicator flashes and then release; LED
flashes quickly 20 times.
2.
R718DB2 will be at off mode by default setting after restoring to factory setting. Press function
key to turn on R718DB2 and to join a new LoRa network.
Note: The device operation of turning off is the same as restoring to factory settings.
6. Sleeping Mode
The device is designed to enter sleeping mode for power-saving in some situations:
(A) While the device is in the network → the sleeping period is Min Interval. (During this
period, if the reportchange is larger than setting value, it will wake up and send a data report).
(B) When it is not in the network → the device will enter sleeping mode and wake up every 15
seconds to search a network to join in the first two minutes. After two minutes, it will wake up
every 15 minutes to request to join the network.
If it’s at (B) status, to prevent this unwanted power consumption, we recommend that users
remove the batteries to power off the device.
7. Low Voltage Alarming
The operating voltage threshold is 3.2V. If the voltage is lower than 3.2V, R718DB2 will send a
low-power report to the Lora network.
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Current
Change≥
Reportable Change
Current
Change
<
Reportable Change
Any
number
between 1~65535
Any
number
between 1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval