background image

 

 

5. Data Report       

  Data report configuration and sending period are as following: 

 

 

 

 

 

 

 

 

 

 

 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change

≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0. 

Report 

per Min Interval 

Report 

per Max Interval 

The device will immediately send a version package report and a report data with temperature and voltage values. 

The device sends data in the default configuration before any configuration is done. 

Default setting: 

Maximum time: Max Interval = 900 seconds 

Minimum time: Min Interval = 900 seconds   

(by default, the current voltage value is detected per Min Interval) 

   Battery Change: 0x01 (0.1V) 

         Temperature Change: 0x00064 (10°C) 

 

Note:   

(1)

 

The real data sending cycle will be programmed before shipment.   

(2)

 

The interval between two reports must be the minimum time 

 

Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver 

http://loraresolver.netvoxcloud.com:8888/page/index

 to resolve uplink data. 

 

Summary of Contents for R718CK2

Page 1: ... Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Important Maintenance Instruction 9 ...

Page 3: ...eries It has good physical and chemical properties good thermoelectric potential stability and high oxidation resistance at high temperatures and is suitable for oxidizing and inert atmospheres LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method gre...

Page 4: ...bject 2 way thermocouple detection Compatible with LoRaWANTM Class A Frequency hopping spread spectrum Configuration parameters can be configured via a third party software platform Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption longer battery life support Battery life is determined by sensor reporting frequency and other variables please refer t...

Page 5: ...for 5 seconds success The green indicator remains off fail Had joined the network Not at factory setting mode Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network when the device is on Suggest to check the device verification information on the gateway or consult your platform serv...

Page 6: ...ature and voltage values The device sends data in the default configuration before any configuration is done Default setting Maximum time Max Interval 900 seconds Minimum time Min Interval 900 seconds by default the current voltage value is detected per Min Interval Battery Change 0x01 0 1V Temperature Change 0x00064 10 C Note 1 The real data sending cycle will be programmed before shipment 2 The ...

Page 7: ... Signed2Bytes unit 0 1 C Reserved 3Bytes fixed 0x00 Example 1 of Uplink 0116012400FD0109000000 1st byte 01 Version 2nd byte 16 DeviceType 0x16 R718CK2 3rd byte 01 ReportType 4th byte 24 Battery 24Hex 36 Dec 36x0 1v 3 6v 5th 6th byte 00FD Temperature1 00FD Hex 253 Dec 253x0 1 C 25 3 C 7th 8th byte 0109 Temperature2 0109 Hex 265 Dec 265x0 1 C 26 5 C 9th 11th byte 000000 Reserved Example 2 of Uplink ...

Page 8: ...ort Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v TemperatureChange 2byte Unit 0 1 Reserved 2Bytes Fixed 0x00 1 Configure R718CK2 report parameters MinTime 1min MaxTime 1min BatteryChange 0 1v TemperatureChange 1 C 10 0 1 C Downlink 0116...

Page 9: ...p and performs data sampling according to MinTime Interval When it is sleeping it does not collect data Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data REPORTS 3 6V Wakes up and collects data REPORT 3 6V Wakes up and collects data REPORTS 3 6V Wakes up and collects data 3 5V 3...

Page 10: ...evice gets wet please dry it completely Do not use or store the device in dusty or dirty environment It might damage its detachable parts and electronic components Do not store the device under excessive heat condition High temperature can shorten the life of electronic devices destroy batteries and deform or melt some plastic parts Do not store the device in places that are too cold Otherwise whe...

Reviews: