background image

 

 

Report configuration example: 

 

1.

 

Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, Temperaturechange = 10

 

       Downlink: 0114003C003C0100640000 

       Device returns: 

              8114000000000000000000 (configuration successful) 

              8114010000000000000000 (configuration failed) 

 

2.

 

Read device parameters 

       Downlink: 0214000000000000000000 

       Device returns: 

              8214003C003C0100640000 (current device configuration parameters) 

 

 

 

 

 

 

 

 

 

 

 

 

Description 

Device 

CmdID 

Device

Type 

NetvoxPayLoadData 

ConfigReport 

Req 

R718B2 

0x01 

0x14 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

BatteryChange 

(1byte Unit:0.1v) 

TemperatureChange   

(2byte Unit:

0.1℃

Reserved 

(2Bytes,Fixed 0x00) 

ConfigReport 

Rsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes,Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

BatteryChange 

(1byte Unit:0.1v) 

TemperatureChange 

(2byte Unit:

0.1℃

Reserved 

(2Bytes,Fixed 0x00) 

Summary of Contents for R718B2

Page 1: ...etvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ...e 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 9 7 1 To determine whether a battery requires activation 9 7 2 How to activate the battery 9 8 Important Maintenance Instruction 10 ...

Page 3: ...mmunication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti interference ability and so ...

Page 4: ...oRaWANTM Class A Frequency hopping spread spectrum Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is determined by the sensor reporting frequency and other va...

Page 5: ...e to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting mode Turn on the device to search the previous network The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network when the device is on Suggest to check the device verification information...

Page 6: ...n uplink packet including temperature1 temperature2 and battery voltage The device sends data in the default configuration before any configuration is done Default setting MaxTime Max Interval 15 min 900s MinTime Min Interval 15 min 900s BatteryChange 0x01 0 1V TemperatureChange 0x0064 10 C Note The device report interval will be programmed based on the default firmware which may vary The interval...

Page 7: ...00640000 current device configuration parameters Description Device CmdID Device Type NetvoxPayLoadData ConfigReport Req R718B2 0x01 0x14 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v TemperatureChange 2byte Unit 0 1 Reserved 2Bytes Fixed 0x00 ConfigReport Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadCo...

Page 8: ...ter than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculat...

Page 9: ...e secure use screws purchased to secure the unit to a wall or other surface see Figure 2 below Note Do not install the device in a metal shielded box or in an environment with other electrical equipment around it to avoid affecting the wireless transmission of the device R718B2 is suitable below scenarios Oven Industrial control equipment Semiconductor industry 2 When R718B2 is compared with the l...

Page 10: ...r if the storage temperature is too high This lithium chloride layer prevents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from reliable vendors and the b...

Page 11: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...