6
Example of Report configuration
FPort
:
0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 bytes
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, Temperaturechange = 0.1°C
Downlink: 0195003C003C0100010000
Devices return:
8195000000000000000000 (configuration is successful)
8195010000000000000000 (configuration is failed)
(2) Read device parameters
Downlink: 0295000000000000000000
Devices return:
8295003C003C0100010000 (current device configuration parameters)
Description
Device
CmdID
Device
Type
NetvoxPayLoadData
ConfigReportReq
R718B
0x01
0x95
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Temperature
change
(2byte Unit:0.1°C)
Reserved
(2Bytes,Fixed 0x00)
ConfigReportRsp
0x81
Status(0x00_success)
Reserved (8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved (9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Temperature
change (2byte
Unit:0.1°C )
Reserved
(2Bytes,Fixed 0x00)