Command Configuration:
MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, TemperatureChange = 1℃
Downlink
:
01BC003C003C0100640000 003C(H
ex)
= 60(D
ec)
,0064(H
ex)
= 100(D
ec)
Response
:
81BC000000000000000000
(
Configuration success
)
81BC010000000000000000
(
Configuration failure
)
(
2
)
Read Configuration:
Downlink
:
02BC000000000000000000
Response
:
82BC003C003C0100640000
(
Current configuration
)
Example for MinTime/MaxTime logic:
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time Max Time
S
leeping (Min Time)
S
leeping (Min Time
)
1H 2H 3H
Description Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R711A
0x01
0xBC
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit:0.1v)
Temperature
Change
(2byte
Unit:0.01℃)
Reserved
(2Bytes, Fixed
0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved (9Bytes, Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit:
0.1v)
Temperature
Change
(2byte Unit:
0.01℃)
Reserved
(2Bytes, Fixed
0x00)
Wake up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V