7
(1)
Configure R313K device parameter MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
Downlink
:
019E003C003C0100000000
Device return
:
819E000000000000000000 (configuration success)
819E010000000000000000 (configuration failure)
(2)
Read R313K device parameter
Downlink
:
029E000000000000000000
Device return
:
829E003C003C0100000000 (device current parameter)
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime) Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BtteryVoltageChange
value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping(MinTime) sleeping sleeping sleeping
0H
15
th
M 30
th
M 45
th
M
1H
2H
Wake up and collects data
REPORTS 2.8V
Wakes up and collects data
REPORTS 2.8V
Wakes up and collects data
REPORTS 2.8V
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V