6. Installation   

 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Tear off the 3M adhesive on the back of the motion detection 

counter, and stick the body to the surface of the smooth object 

(or motor) (please do not stick to the rough  surface to prevent 

the device from falling off after a long time) 

 

Notes: 

 

Wipe the surface of the object clean before installation to 

avoid dust on the surface of the object and affect the paste 

effect of the device. 

 

Do not install the body in a metal shield box or in an 

environment surrounded by other electrical equipment to 

avoid affecting the wireless transmission of the equipment. 

 

  

 

2. When the device detects the sudden movement or 
vibration of the item (or the motor), the device status 
changes; wait for a period of time (Deactive Time-default 
5 seconds, can be modified) after entering the static state, 
it is counted to be vibration once, the count is increased by 
1. In the mean time, it will send the number of 
simultaneous vibrations. 
 
Notes: 
(1) After the device vibrates and before it enters the 
stationary state, if it continues to vibrate, it is postponed 
for 5 seconds until the device enters the stationary state 
before counting to 1. 
(2) After the device is powered off, the count data is 
cleared. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The motion detection counter (R311FB) is suitable for the 
following scenarios: 

 

Industrial equipment 

 

Industrial instrument 

 

Medical instruments   

Where it is necessary to detect the number of motor runs 

 

 

Summary of Contents for R311FB

Page 1: ...Model R311FB Wireless Activity Event Counter Wireless Activity Event Counter User Manual...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 3 5 Data Report 4 6 Installation 7 7 Relative Devices 8 8 Important Maintenance Instruction 8...

Page 3: ...on methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter readi...

Page 4: ...d insert the battery the device will memorize previous on off state by default 2 On off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other energy...

Page 5: ...311FB vibration alarm The device detects sudden movement or vibration and the quiescent state changes The device waits for a certain period of time DeactiveTime to enter the quiescent state and counts...

Page 6: ...ctive ThresholdRsp 0x86 Threshold 2Bytes Deactivetime 1Byte Unit 1s Reserved 6Bytes Fixed 0x00 1 Configure device parameters MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 0150003C003C010000000...

Page 7: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Page 8: ...detects the sudden movement or vibration of the item or the motor the device status changes wait for a period of time Deactive Time default 5 seconds can be modified after entering the static state i...

Page 9: ...Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy interna...

Reviews: