6. Installation

 

8. Installation   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

1.

 

Remove the 3M adhesive on the back of the

 

3-axis 

Accelerometer Sensor and attach the body to the surface of a 

smooth object (please do not stick it to a rough surface to 

prevent the device from falling off after a long time use). 

Note

 

 

Wipe the surface clean before installation to avoid dust on 

the surface to affect the adhesion of the device. 

 

Do not install the device in a metal shielded box or other 

electrical equipment around it to avoid affecting the wireless 

transmission of the device. 

2. Installation Precautions

 

While installing, it is recommended to install R311FA1 

horizontal while the generator is power-off and in static status. 

After installing and fixing R311FA1, please turn on the device. 

After the device is joined, one minute later, R311FA1 would 

perform the calibration of the device (the device cannot be 

moved after the calibration. If it needs to be moved, the device 

needs to be turned off/powered off for 1 minute, and then the 

calibration would be performed again). R311FA1 would need 

some time to gather the data of three-axis accelerometer & the 

temperature of the generator while it is working normally. The 

data is a reference for the settings of ActiveThreshold & 

InActiveThreshold, it is also for checking if the generator is 

working abnormally.

 

 
 
 
 
 
 
 
 

3-axis Accelerometer Sensor  (R311FA1)  is suitable for the 

following scenarios: 

 Industrial Equipment 

 Industrial Instrument 

 Medical Instruments 

When it necessary to detect 3-axisthe acceleration and velocity 

3.When R311FA1 detects the data of three-axis accelerometer 

exceed ActiveThreshold, R311FA1 would report the data that 

detected. After sending the data of three-axis accelerometer, 

the data of three-axis accelerometer of the device needs to be 

lower than InActiveThreshold and the duration has to be 

more than 5 seconds (cannot be modified) before the next 

detection. 

Note

 

While the data of three-axis accelerometer of the device 

is lower than InActiveThreshold and the duration has to be 

lesser than 5 seconds, at this time, if the vibration continues 

(the data of three-axis accelerometer is higher than 

InActiveThreshold ), it will be delayed for 5 seconds. Until 

the data of three-axis accelerometer is lower than 

InActiveThreshold, and the duration is more than 5 

seconds. 

R311FA1 would send two packets, one is the data of 

three-axis accelerometer, and the other would be sent after 

10 seconds with the data of three-axis velocity. 

Summary of Contents for R311FA1

Page 1: ...gy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in...

Page 2: ...tion 4 5 Data Report 5 5 1 ActiveThreshold and InActiveThreshold 6 5 2 Calibration 6 5 3 Example of ReportDataCmd 6 5 4 Example of ConfigureCmd 8 5 5 Example of MinTime MaxTime logic 10 5 6 The X Y Z...

Page 3: ...methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For e...

Page 4: ...be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low...

Page 5: ...n the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The...

Page 6: ...locity s 1 After the three axis acceleration of the device exceeds ActiveThreshold a report is sent immediately to report the three axis acceleration and velocity 2 After reporting the three axis acce...

Page 7: ...to mechanical stress far beyond solid state electronics The 0g offset is an important accelerometer indicator because it defines the baseline used to measure acceleration After installing R311FA1 use...

Page 8: ...3v 5th 6th byte 6A3E Acceleration X float32 3E6A0000 0 22851562 m s2 7th 8th byte 883E Acceleration Y float32 3E880000 0 265625 m s2 9th 10th byte 1F41 Acceleration Z float32 411F0000 9 9375 m s2 11t...

Page 9: ...n failure 2 Read Configuration Downlink 02C7000000000000000000 Response 82C7003C003C0100010000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R311FA1 0x...

Page 10: ...ice current parameter Description Device Cmd ID Device Type NetvoxPayLoadData SetActive ThresholdReq R311FA1 0x03 0xC7 ActiveThreshold 2Bytes InActiveThreshold 2Bytes Reserved 5Bytes Fixed 0x00 SetAct...

Page 11: ...x Time Sleeping Min Time Sleeping Min Time 1H 2H 3H Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Example 2 based on MinTime...

Page 12: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Page 13: ...the generator while it is working normally The data is a reference for the settings of ActiveThreshold InActiveThreshold it is also for checking if the generator is working abnormally 3 axis Accelerom...

Page 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...