7
Restore function configuration
Description
Device
CmdID
Device
Type
NetvoxPayLoadData
SetRestore
ReportReq
R311DA
0x03
0xA8
RestoreReportSet
(1byte)
0x00_DO NOT report when sensor restore,
0x01_DO report when sensor restore)
Reserved
(8Bytes, Fixed 0x00)
SetRestore
ReportRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
GetRestore
ReportReq
0x04
Reserved
(9Bytes, Fixed 0x00)
GetRestore
ReportRsp
0x84
RestoreReportSet (1byte,
0x00_DO NOT report when sensor restore,
0x01_DO report when sensor restore)
Reserved
(8Bytes, Fixed 0x00)
(3) Do report after sensor stops vibrating
Downlink
:
03A8010000000000000000 (0x01_DO report when sensor restore)
Response
:
83A8000000000000000000 (Configuration success)
83A8010000000000000000 (Configuration failure)
(2) Read restore function:
Downlink
:
04A8000000000000000000
Response
:
84A8010000000000000000 (Current configuration) (report when sensor restore)
Example for MinTime/MaxTime logic:
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time Max Time
S
leeping (Min Time)
S
leeping (Min Time
)
1H 2H 3H
Wake up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V