background image

                                                            

  

  Model

R311DA   

 

 

 

 

Wireless Vibration Sensor, Rolling Ball Type 

 

 

 

 

 

 

 

Wireless Vibration Sensor, 

Rolling Ball Type   

 

R311DA 

User Manual   

 

 

 

 

 

 

 

 

 

 

Copyright©Netvox Technology Co., Ltd.

 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained 

in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX 

Technology. The specifications are subject to change without prior notice. 

 

Summary of Contents for R311DA

Page 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other p...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Page 3: ...spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic met...

Page 4: ...igured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power...

Page 5: ...sted to be about 10 seconds to avoid the interference of capacitor inductance and other energy storage components Network Joining Never joined the network Turn on the device to search the network to j...

Page 6: ...tting Maximum time 3600s Minimum time 3600s Default Every Min Interval will detect the state of the dry contact one time BatteryChange 0x01 0 1V If there are special customized shipments the settings...

Page 7: ...0x00 ConfigReport Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Bat...

Page 8: ...restore Reserved 8Bytes Fixed 0x00 3 Do report after sensor stops vibrating Downlink 03A8010000000000000000 0x01_DO report when sensor restore Response 83A8000000000000000000 Configuration success 83A...

Page 9: ...the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will...

Page 10: ...joining the network is completed please place it indoors 2 The dust at the installation location should be wiped clean before paste the device 3 The battery installation method is as the figure below...

Page 11: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...