background image

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.Tear off 3M release paper of the magnet body and attach the 

body to the door frame and stick it to the door in parallel 

with the door magnet body. (please do not stick it on the 

rough door to avoid falling off after using the device for a 

long time). 

As shown in the enlarged view on the right 

 

 

 

 

 

 

 

 

 

Note: 

 

Wipe the door clean before installation to avoid dust on the 

door and affect the adhesion of the device. 

 

Do not install the device in a metal shielded box or other 

electrical equipment around it to avoid affecting the 

wireless transmission of the device. 

 

The installation distance between the magnet body and the 

magnet should be less than 2cm. 

This figure shows the scene where the door magnetic sensor 

(R311A) is applied to the door (opening and closing). 

It can also be applied to the following scenarios: 

 

Door, window 

 

drawer 

 

Machine room door 

 

Archive room 

 

Closet 

 

Refrigerator and freezer 

 

Cargo ship door 

 

Garage Door 

Places which  are  necessary to detect the opening and 

closing state 

2.When the door is opened, the magnetic body of the door is 

separated from the magnet, and the magnetic device sends 

an "alarm" message. 

 

When the door is closed, the magnetic body of the door is 

merged with the magnet, the device returns to the "normal" 

state, and the status information of the off is sent

Summary of Contents for R311A

Page 1: ...d This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole o...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Important Maintenance Instruction 10...

Page 3: ...any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring It has...

Page 4: ...ed through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consu...

Page 5: ...will enter engineer testing mode Network Joining Never joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fa...

Page 6: ...ot be 0 Report per Min Interval Report per Max Interval The device will immediately send a version packet report along with an uplink packet including reed switch status and battery voltage Data will...

Page 7: ...Min Time 1H 2H 3H Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device CmdID Device Type NetvoxPayLoadData Conf...

Page 8: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matt...

Page 9: ...ce between the two needs to be less than 2cm the dust in the installation position of the equipment needs to be wiped clean and then affixed to the equipment 3 The battery installation method is shown...

Page 10: ...n of the device The installation distance between the magnet body and the magnet should be less than 2cm This figure shows the scene where the door magnetic sensor R311A is applied to the door opening...

Page 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: